Cornell Communications 4800 Series Rescue Assistance Digital System Spec

File Preview
File Preview
Click below to download for free

Text Preview

Version 2.0 January 3 2012 of Refuge Area of Rescue Assistance Signal System 4800 Audio Visual Series Specifications document specifies Area of Refuge Area of Rescue Assistance equipment for emergency This system provides voice communication that is initiated by depressing the call button transmitting the signal to a central control panel manufactured by Cornell Inc Milwaukee WI 1 General SUMMARY Includes Furnish install and wire all equipment associated with the of a Digital Area of Refuge Area of Rescue Assistance Signal System for IBC 2012 and ADA Americans with Disabilities Act requirements work shall include a main control panel optional remote control panels an modem optional proprietary field switches for systems over 8 zones call stations power supply s outlet boxes cables and wiring as shown on drawings and as specified herein SUBMITTALS Data sheets on all equipment being provided as well as recommended types Internal control cabinet drawings showing internal block diagram shall be provided Wiring diagrams showing typical field wiring as well as single line floor plan indicating equipment locations as as cable routings and quantities Data Submit product data including manufacturer Specifications product sheet for specified products Drawings Submit shop drawings showing layout profiles and product including anchorage and accessories Include cabling diagrams diagrams station installation details and equipment cabinet details Assurance Submittals Submit the following Reports Certified test reports showing compliance with specified characteristics Instructions Manufacturer installation instructions 2.0 January 3 2012 Field Reports Manufacturer field reports specified Submittals Submit the following and Maintenance Data Operation and maintenance data for products in accordance with Division 1 Closeout Submittals Data and Operation Data Section Warranty documents specified herein Closeout one year maintenance contract offering continued factory authorized of this system shall be provided as part of this contract contractor shall furnish manufacturer manuals of the completed including individual specifications sheets schematics inter panel intra panel wiring diagrams information necessary for the proper maintenance and of the system must be included four copies built drawings that include changes to wiring wiring designations box labeling and other pertinent information shall be supplied completion of the project a minimum of two 2 hours of in service training with the sessions shall be broken into segments that will facilitate the of the system users in operating station equipment manuals and user guides shall be provided at the time training WARRANTY Warranty Refer to Conditions of the Contract for project warranty Manufacturer Warranty Submit for Owner acceptance manufacturer warranty document executed by authorized company official warranty is in addition to and not a limitation of other rights may have under Contract Documents Period Specify term years commencing on the Date of Completion materials and installation shall be guaranteed to be free of defects in and workmanship for one year after final acceptance of and tests 2.0 January 3 2012 INSTALLATION STANDARDS system shall be installed in accordance with the IBC 2009 and ADA with Disabilities Act requirements completed system shall be in compliance with state and local electrical codes SYSTEM OPERATIONS wiring shall test free from grounds and shorts according to the manufacturer wiring diagrams 4800 Digital Emergency Communications System requires installation by trained authorized dealers distributors in accordance with ANSI NFPA 70 Electrical Code and NFPA 72 Fire Alarm Code trained personnel familiar with Telecommunications Industry 568 TIA EIA standard are required for proper installation Failure to the wiring correctly will cause damage to the system and void the 4800 Digital Emergency Communication System shall be installed in a indoor dry environment with temperatures maintained between 55 95 install and place into operation a Digital Rescue Assistance System as on the drawings and as specified herein common control panel shall be provided at the main building entrance or other as authorized by local authority or the fire department where shown on drawings to indicate light and tone signals from multiple remote call stations allow voice communication Optionally up to four secondary panels can also installed throughout the building to allow alternate locations to respond to a for assistance When the remote call station switch is activated a one shot tone is made at the system is operational a LED signals power on call station and a LED is lit that is steady The call is displayed on the control panel s with a tone along with a display of the call its location on a 40 character LCD four line display the alarm signal is answered by the control panel the remote call is signaled by the LED flashing that voice communication is 2.0 January 3 2012 communication with the remote call station can then be initiated the control panel via a handset modem connection to a public telephone system shall be after a programmable time delay system shall poll supervise all the call stations control panels and switches on a continuous basis at least every 200 seconds to identify faults and defective equipment Faults will be alerted and displayed at control panel s 2 Products Rescue Assistance System Digital RESCUE ASSISTANCE AUDIO VISUAL EQUIPMENT A Manufacturer Cornell Communications Inc 7915 N 81st St Milwaukee WI 53223 3830 800 558 8957 414 351 4660 Fax 414 351 4657 PRODUCT SUBSTITUTIONS No substitutions permitted CORNELL 4800 RESCUE ASSISTANCE DIGITAL SYSTEM AND This system shall consist of multiple remote call stations which will with one to five control panels and have access to a public system for external alarm notification and two way voice Expansion Switches will also be utilized when the number of stations exceeds eight The digital communication system is based on Ethernet CobraNet technology consists of four primary components a Control Panel Call Station s Switch es and Power Supplies In any given system there will be least one Control Panel and between one and 255 Call Stations The system support a maximum of five Control Panels For larger systems Expansion may be used The Expansion Switch is based on the Control Panel design The Control Panel and Expansion Switch are eight port switches The Control Panel and or Expansion Switches power the Call Stations The system interconnects using standard CAT 5 cable Ethernet restriction of 100m of cable between a Control Panel and or Switch and endpoint applies System also requires 1 Pair 16 AWG stranded non shielded cable from PS to the Control Panels Switches for power and 1 Pair 22 AWG 2.0 January 3 2012 non shielded cable circulating from the PS to all of the Power J9 connections on the Control Panel Panel s the system is operational a LED signals power on When the is operating in battery power mode a different LED will be on main control panel shall be a CORNELL Model A 4800M or remote panel shall be a CORNELL Model A 4800R with capacity for 255 utilizing Ethernet CobraNet technology The panel can be surface at the Main Fire Department Entrance to the building or other as authorized by the local authority or fi

Related Files