Cornell Communications Aura 2 0 Architectural Product Specification
File Preview
Click below to download for free
Click below to download for free
File Data
Name | cornell-communications-aura-2-0-architectural-product-specification-6854203719.pdf |
---|---|
Type | |
Size | 650.80 KB |
Downloads |
Text Preview
Engineering Specifications A Alarm Monitoring and Alerting System System system shall be a universal notification tool that is designed to monitor alarm events occurring within a of discrete environments and provide a common method for managing the delivery of alerts Each event shall be logged in the system database and retained for reporting purposes A software engine shall provide a flexible mechanism to consolidate multiple devices into a common for reporting and management The system shall not require frequent user activation once the types and responders have been uniquely designated in the software tables The persistent shall be leveraged to provide an integrated alarm monitoring and alerting system which links devices into a common system When an event occurs the notification shall be transmitted by a wired or a wireless device and the event logged devices shall include mobile duress transmitters door window monitors compressors sensors alarm relays motion detectors fire and smoke alarms as well as a wide of other devices The system shall deliver text outward to a variety of devices The alert messages the alarm event shall also be delivered in a text format via the use of selected devices The system shall provide both real time and historical reporting on the status of every designated device reporting can be used to identify problem areas shall be reported to a wide array of communications technologies text messages to cellular pagers and PC workstations system will include all necessary hardware and software to offer all referenced capabilities Functionality Communicator or Series 4000 wired Nurse Call Systems for data and recordkeeping the system will and record all alarms associated with devices programmed into the Nurse Call System This data be easily access by users with proper password accessibility by any computer on the network As a function alert notification to other staff devices can be supported by this system In addition all wired products including Light Status Systems Door Monitoring and Area of Rescue Assistance hard systems can be integrated into the system for data logging and broadcast notification the wireless transmitters sensors once an alert event occurs a monitored transmitter sends a signal that received by either the central application receiver or range extenders and then ultimately sent to the infrastructure The system software then notifies the alerted personnel and logs the alert event for purposes The system shall support a variety of software interfaces in order to integrate a diverse of and render a common database of monitored devices Additionally the system shall have the ability to alert messages text to a wide range of devices of communication devices Components AURA 2.0 system consists of an application server tower operating with Windows XP The server shall the capability to support POP 3 e mail as well as text capability for alert delivery The server shall a 10 100 megabit network interface card The server shall also include a wireless receiver for alerts from a family of wireless transmitters sensors The system shall have the ability to have up to separate viewing workstations wireless monitoring devices ie receivers transmitters range extenders shall operate in the 902 to frequency band To provide extended range for larger installations wireless range extenders shall available In order to provide maximum reliability and interference immunity all wireless sensors and range extenders shall use a spread spectrum frequency hopping technique which upon activation send redundant messages across a bandwidth that is at least 10MHz wide wireless sensors and repeaters shall be capable of periodically transmitting check in signals to monitor integrity of their wireless links to compatible receivers and panels These transmitters and range shall be able to be programmed for check in transmissions that occur as frequently as every 60 The information provided in these check in messages shall at least include alarm and battery status receivers shall resolve signals from the transmitters and repeaters specifically registered into the even in the presence of RF interference The receivers shall interface to any security or control with either a direct serial data interface or with relay or open collector outputs that connect to the panel zone inputs Frequency 902 928MHz Spread Spectrum via Frequency Hopping License None per FCC Part 15 Certification Extender accommodate premises protection in large commercial and industrial facilities or to support future site or remodeling a range extender product shall be available to increase alarm transmission range range extender must provide at least 200 milliwatts of effective radiated RF power The range extenders have the ability to communicate with other range extenders thus allowing for multiple range extenders be installed as a micro cellular network Alarm and supervisory check in signals from transmitters must be reliably with multiple range extenders in the system The range extender shall NOT require a wire back to the receiver or panel Requirements 14 VAC Transformer included to convert from 120 VAC with battery backup Field Transmit Range 4 Miles Weatherproof for Outdoor Installations Operating Temp 32 to 140 Sensors Transmitters wireless protection equipment shall include at least the following wireless sensors Universal Transmitter that supports the following a normally open or normally closed input an onboard input with wide gap magnet an End Of Line EOL Resistor used for supervising wires between switch and transmitter High power universal transmitter Single and Double Button Panic Pendants with at least two Water Resistant models Passive Infrared Motion Detector with Integrated Transmitter Smoke Detector with Integrated Transmitter Glass Break Detector with Integrated Transmitter Open Field Range 1 mile medium power products 2 miles high power products Operating Temp 32 to 140 wireless protection equipment shall include receivers that interface with hardwired inputs of all security panels In some cases a serial data interface will translate messages from the wireless receiver to internal communications of the control panel When a serial data interface is not available the receivers be available in at least four models that accommodate 1 4 and 16 wireless sensors respectively Each these models also shall provide mechanical Form C relay outputs that connect to the control panel zone and provide electrical isolation between the panel and receiver and to accommodate specialized addition to wireless sensor alarms each model shall have the capability of reporting the following fault conditions low battery tamper and missing no check in transmissions for preprogrammed interval All receivers shall be capable of reporting a missing transmitter condition inactive for programmable supervision windows of 1 to 24 hours depending upon the requirements of the requirements 11 14 VDC Typically available from interfacing panel Outputs Form C Relays UL rated at 2 A 28 VDC or 110 VAC Ambient Operating Temp 32 to 140 Software software shall have a user graphical interface which shall have components screens that show alerts have been received by the system instant messaging to pre programmed user or user groups alert data and administrative functions It shall be password protected so staff or others cannot close out the screen Administrator function shall be password protected Survey Tool portable hand held easy to use survey kit shall be available that will measure transmitter signal strength well as signal margin dBm above background noise of received signals The survey kit shall have the to determine the performance of the transmitters to be installed and if necessary the amount and of wireless repeaters Assurance insure consistent product quality the wireless equipment manufacturer is ISO9001 registered with an certification 7915 N 81st St Milwaukee WI 53223 800 558 8957 Fax 414 351 4657 www cornell com