Cornell Communications Communicator RN System Reference Guide

File Preview
File Preview
Click below to download for free

Text Preview

COMMUNICATIONS INC North 81st Street WI 53223 RN NURSE CALL SYSTEMS 5000 Tone Visual 5500 Audio Visual HCE CUMULA 1 2 3 REFERENCE GUIDE NO D 5500 REF 09 10 2010 2 of 32 THIS SERVICE MANUAL Communicator Service Manual Cornell Part 05 6887023 101 is intended to provide the information needed to plan install operate and service a complete Communicator system MANUAL CONTAINS THE FOLLOWING SECTIONS A Table of Contents A System Reference Guide this document which provides general information safety and systems planning information A complete set of Installation and Service Guides ISG for the various system used within the Communicator RN product line These ISGs each have own Cornell Part Number and have been organized into the following groups Controllers User Interface Equipment Addressable Stations Visual non audio types Addressable Stations Audio Visual Non Addressable Stations Lights Call Cords Appendices which include the following Appendix A Communicator RN Equipment List Appendix B Reserved for Future Use Appendix C Communicator RN Configuration Instructions Appendix D Radio Paging Configuration Instructions ORDER TO ASSIST YOU IN FINDING BASIC INFORMATION QUICKLY FOLLOWING PAGE CONTAINS A OF CONTENTS FOR REFERENCE GUIDE DOCUMENT 09 10 2010 3 of 32 GUIDE CONTENTS DESCRIPTION A summary of the various components and important concepts to understanding what makes up a Communicator RN Nurse Call System 5000 TONE VISUAL SYSTEMS 5500 AUDIO VISUAL SYSTEMS PAGE 5 PAGE 7 RN EQUIPMENT LIST Listing of the components that be used within Communicator RN Nurse Call Systems PAGE 13 PLANNING This section explains important factors to consider in designing and Communicator RN Nurse Call Systems including the following topics 1 GENERAL LAYOUT OF FACILITY UNITS 2 3 BREAK DOWN EACH CARE UNIT 4 DETERMINE SYSTEM TYPE FOR EACH UNIT 5 U L LISTING CONSIDERATIONS 6 DETERMINE PATIENT STATION SERIES 7 PICK STATIONS REQUIRED FOR EACH SCENARIO multiple examples of typical facility types PAGE 16 PAGE 17 PAGE 19 PAGE 19 PAGE 19 detailed example for one of the facility types PAGE 20 8 9 LIST THE MODEL NUMBERS ACCESSORY ITEMS PAGE 22 10 VERIFY MAXIMUM CABLE RUN DISTANCES PAGE 24 DESCRIPTION Detailed information on the Cable Types for use with the Communicator RN Nurse Call System PAGE 24 REQUIREMENTS Information required to plan for proper AC Connections and Stand By Battery Requirements PAGE 26 BOXES A short note about Back Boxes Refer to Guide at end TOOLS ACCESSORIES Information about special tools PAGE 27 and related information needed for proper installation PAGE 28 DRAWINGS AND CHARTS The following drawings and are provided to aid you with the following Describes typical wiring type technique PAGE 29 STATIONS BACK BOX FEATURES GUIDE to help in selection of the correct stations based features and corresponding Back Boxes required for each PAGE 30 STATIONS INPUTS AVAILABLE FOR STATIONS Spreadsheet to help you quantity and purpose of Inputs Outputs with each Addressable Station PAGE 31 LAMP SELECTION GUIDE Spreadsheet to help you select correct Dome Lamp number colors of bulbs for different of stations priorities within a room PAGE 32 09 10 2010 4 of 32 DESCRIPTION 5000 TONE VISUAL VERSIONS 5000 Nurse Call Systems are Tone Visual Signaling Systems which means that when calls placed on the system Indication is performed via tones Electronic Sounders Beepers Indication is provided via lamps and or LEDs 5000 Nurse Call Systems do not include voice communications or intercom talk paths Communicator 5000 Visual Nurse Call System typically consists of a microprocessor based control unit panels duty stations a group of addressable stations associated non addressable stations and lights All of these devices are interconnected to provide multi level signaling via tone visual The following information explains the role of each of the various components found within a system ADDRESSABLE STATION LOOP DATA LOOP of the key concepts in understanding both the 5000 and the 5500 Nurse Call Systems is the concept of which is a bi directional data circuit connecting all addressable stations on the system to the Unit Loop supports a total of 40 Addressable Stations as follows 32 Addresses used by every addressable station type except for Duty Stations 8 Station Addresses which are only used by Duty Stations Non Addressable stations MUST connect to the 5000 Series Nurse Call System via an Addressable UNIT control unit is the functional core of each 5000 Series system Each system requires one Control Unit Control Unit is essentially a panel with a plain metal door which contains the following equipment Power supplies to provide operating power to all other system components A Processor Module This microprocessor based component regulates the operation of the system and self diagnostic functions The Processor Module is the electronic hub to which all other system connect UNIT CAPACITIES capacity of each 5000 Series Control Unit is as follows Unit Model No with Dome Lamps Dome Lamps Tone Visual Version If Tone Visual Console is needed select corresponding 5500 Series Controller Control Unit is typically installed out of sight in a secure central location such as an equipment storage electrical room 09 10 2010 5 of 32 MODEL HRN7614UA provide the primary interface between Care Staff and the 5000 Series Nurse Call System Annunciator is a 4 gang size wall mounted device which provides Tone Visual indication by means of following features A Silence pushbutton is provided to temporarily silence tones being produced at the Annunciator new status condition will automatically cause re sound operation A Test pushbutton is provided for actuation of a Lamp Test function which allows operation of all LEDs to be verified pushbuttons may also be utilized to actuate several diagnostic display modes which are useful installation and for identifying and troubleshooting fault conditions A dual tone sounder produces different sounds tone patterns for different status conditions An array of 32 Programmable Red LEDs 4 rows of 8 provides visual indication of the corresponding that are mapped to each LED Typically one LED corresponds to a bed or a room Each of LEDs illuminates flashes at different rates in order to indicate the highest priority of any active call is linked to it A Green LED is provided to indicate that the u

Related Files