Cornell Communications Door Monitor 1000 Series Product Specification

File Preview
File Preview
Click below to download for free

Text Preview

Door Monitor System 1000 Specs document specifies door monitoring equipment for monitoring unwanted entry or from a secured area This system shall be designed to comply with Design of the Door Monitor System as manufactured by Cornell Communications Milwaukee WI 1 General SUMMARY Includes The electrical contractor shall furnish and install a Door Monitoring System as described herein and shown on the SYSTEM DESCRIPTION SUBMITTALS Requirements Provide door monitor equipment which been manufactured and installed to maintain performance criteria by manufacturer without defects damage or failure Submit listed submittals in accordance with Conditions of the and Division 1 Submittal Procedures Section Data Submit product data including manufacturer s Spec product sheet for specified products Drawings Submit shop drawings showing layout profiles and components including anchorage and accessories Include diagrams wiring diagrams station installation details and cabinet details Assurance Submittals Submit the following Reports Certified test reports showing compliance with performance characteristics Instructions Manufacturer s installation Field Reports Manufacturer s field reports herein Submittals Submit the following and Maintenance Data Operation and maintenance data installed products in accordance with Division 1 Closeout Maintenance Data and Operation Data Section methods for maintaining installed products and precautions cleaning materials and methods detrimental to finishes and Include troubleshooting guide wiring terminal and equipment parts list Warranty documents specified herein WARRANTY Warranty Refer to Conditions of the Contract for project provisions Manufacturer s Warranty Submit for Owner s acceptance standard warranty document executed by authorized official Manufacturer s warranty is in addition to and not a of other rights Owner may have under Contract Documents Period Specify term years commencing on the Date of Completion BASIC SYSTEM OPERATIONS zone switch contains a red and a green LED Each time the zone is pressed the zone status toggles between armed and disarmed green LED indicates the disarmed status The associated door may be without causing an alarm A short and or open in the door contact will cause the panel to go into the alarm condition steady red LED indicates the armed status If an armed door is opened alarm condition occurs The red LED will flash and an intermittent tone will sound Pressing the cancel tone switch on the master panel silence the audio tone but will not clear the alarm If another zone go into the alarm condition the tone would again sound until the tone switch is pressed or until all alarms are canceled cancel an alarm simply press and release the zone switch This will the zone to the disarm status and automatically cancel the alarm 2 PRODUCTS DOOR MONITOR EQUIPMENT Manufacturer Cornell Communications Inc 7915 N 81st St Milwaukee WI 53223 3830 800 558 8957 414 351 4660 Fax 414 351 4657 PRODUCT SUBSTITUTIONS No substitutions permitted CORNELL 1000 DOOR MONITOR SYSTEM AND COMPONENTS Operations of the switch when in an armed condition at a station shall initiate a call to the master station and activate flashing LED light and audible signal for that zone of a call at the master station shall cause both an audible visual signal The location of the remote door switch shall be at the master station shall silence the audible alarm at the master station only annunciation signals shall remain illuminated until reset by the operator The system operator shall reset visual annunciation signals A 1000 Series Door Monitor System is designed to operate on 12VDC power Connecting an AC power source or a DC supply with a voltage above 12V will damage the system sure you are using one of the following Cornell power P 512243A or B 5243A minimum 18 gauge 2 conductor wiring from power supply to master panel Supply Features alarm volume Volume of intermittent tone is with a screwdriver from the front of the master panel contacts The system can use either normally open N O normally closed N C contacts Two 22 gauge wires required door switch and zone card output per zone Each A1211 A 1511 zone card has a negative open collector transistor output at terminal 9 turns on whenever that zone is in the alarm condition 500mA 40VDC output system The terminal on the tone board a switched negative open collector transistor output which on whenever any zone is in the alarm condition turns off when all alarms are canceled Rating 40VDC status output Each A 1211 A1511 zone card has a door output at terminal 11 switched negative open collector that turns on whenever the door is open regardless of status Rating 500mA 40VDC switch disable Cutting the factory installed Zone Switch jumper between terminals 1 and 3 of an A 1211 A 1511 card will disable the zone switch from making changes in the status of the door Status changes will then only possible using a remote zone control product See Remote Monitor Control Products switch disable during Alarm Automation Cutting jumper on an A 1211 A 1511 will disable the zone switch from making in the armed disarmed status of the door only when the is in the alarm condition The zone switch will still function the zone is ether disarmed or armed Once in the alarm clearing the alarm will only be possible from a remote control product if the zone switch enable jumper is cut the zone will be disabled under all conditions Zone Monitor Control Products The Remote Control Panel duplicates the functions of Master Panel except it has a high low switch instead of a Tone switch for control of the alarm tone When the Panel tone is silenced the tone for the Remote Control is also silenced Individual zones A 1601 have one green one red LED and a momentary three position center neutral switch Activating the toggle switch to the left or right will or arm the zone respectively More than one A 1600 panel be used Two 18 gauge conductors one 22 gauge plus four 22 gauge conductors per zone all to panel The Remote Monitor Panel provides a visual and indication of any or all zones Each zone A1701 contains green LED and one red LED The panel contains a tone hi low to control the audible alarm tone volume When the Master tone is silenced the tone at the A 1700 panel is also More than one A 1700 panel may be used Two 22 gauge conductors one 22 conductor plus 22 gauge conductors per zone all to master panel Remote Control Station for a single zone comprised one green LED one red LED a key switch and a toggle switch a single gang stainless steel plate The key switch will the use of the toggle switch When enabled the switch will change the status of that zone Requires 5 conductor 22 gauge cable to Master A key operated switch with built in timer designed to authorized personnel to pass through the door when the is armed The A 1801 has a key witch and red LED mounted a single gang stainless steel plate The red LED will glow when zone is armed The red LED will flash when the zone is in the condition Operating the key switch will disarm the zone and the timer allowing the user to pass through the door After the adjustable time period 1 second to one minute that zone will automatically re arm itself Requires 5 conductor 22 gauge cable from switch Master Panel A

Related Files