Cornell Communications Door Monitor Overview 1000 Series
File Preview
Click below to download for free
Click below to download for free
File Data
Name | cornell-communications-door-monitor-overview-1000-series-5064817932.pdf |
---|---|
Type | |
Size | 1.57 MB |
Downloads |
Text Preview
Door Monitor Series Monitor 1000 Series Door Monitor System Series 1000 Door monitor System allows you to configure the right system for many door applications We use anodized aluminum and LED to trouble free performance year year How it works The master panel controls and monitors each door in the system constantly via the zone Remote Panels are attached to the master control and will display the same as the master stations Doors can be disarmed if being used like the main entrance during the day these zones be identified with a lit green LED Changing of the zones from arm disarm is as easy as touching the button on the master using the switch on the remote control panel or disarming at the zone using a key access code at the keypad All panels are equipped with sound which can be muted for noise free applications Any station can be used on any zone so a facility can mix and match to their specific Panels A 1000 master panel shows the status of each door panel is equipped with An audible tone when a zone is alarmed Switches which allows for someone to activate the door with the push of a button The switches are equipped with LED indicators one red armed and one green unarmed for each zone Flush surface or desktop mountable From 4 28 zones in increments of 4 Tone mute switch Volume control through a screwdriver hole in front of the panel panels are available Please contact your Cornell representative for information Control A 1600 remote control panels allow for remote control of master panel and its functions The panel includes Flush surface or desktop mountable Will accommodate the same amount of circuits as master panel A steady green LED indicates unarmed a steady indicates armed a flashing red with intermittent means a zone is in alarmed status Switch to activate deactivate zone Tone volume is adjustable via hi low switch Plastic designator strips to indicate zones Monitor A 1700 remote monitor panels allow for remote monitoring master panel The panel includes Flush surface or desktop mountable Will accommodate the same amount of circuits as master panel A steady green LED indicates unarmed a steady indicates armed a flashing red with intermittent means a zone is in alarmed status Tone volume is adjustable via hi low switch Plastic designator strips to indicate zone Zone Control A 1800 remote zone control model A 1800 allows for keyed zone control of individual doors The station Steady red LED to indicate armed flashing red when Steady green LED to indicate unarmed Key switch needed to change the status of the zone Toggle switch to arm disarm alarm Optional tone Zone Control with Time Delay A 1801 remote zone control with time delay model A 1801 allows a keyed access zone control of individual doors with a time so the door stays armed after a predetermined amount time has lapsed The station includes A key switch used to activate the disarm function Time adjustable from 5 60 second time delay after that the will arm itself again One red LED to indicate armed status when lit alarmed when flashing and LED is off when door is Optional tone Zone Keypad Stations A 1806D and A 1808D remote zone keypad stations allow for access code to restricted areas The stations include Quick change access codes when required User programmable via the keypad 48 hour power loss code retention Model A 1808D allows for a 10 60 second exit delay Model A 1806D allows for remote arm disarm and exit functions Optional tone Experience over 30 years Cornell has provided the communication requirements of the security elder care educational business markets Cornell is the quality time delivery source for all of your solutions Our thousands of installations nationwide is your Cornell we believe consistent reliability is essential to nurse call product Our Series 1000 Door Monitor is not only tested at our factory but time proven in field Series 1000 is manufactured and designed by Cornell down to the circuit boards and mounting plates We a product line that is proven for reliability and function keeping a low cost solution to a facilities security Service Support experienced and technically qualified staff is available to assist you in analyzing your and installation requirements and identifying solutions that match your needs service is just a phone call away more information about our Door Monitor System or the line of Cornell products contact us today complete line of Nurse Call systems for Senior Housing applications basic Visual Call Two way Voice and Wireless solutions when is required offer Assistance systems are also available to assist communication needs of the ADA code along with assisting people assistance in campus and parking garages Status systems to improve patient flow in any clinic