Cornell Communications Emergency Stations E-101 & E-103-E-113

File Preview
File Preview
Click below to download for free

Text Preview

Stations with Push Button or Drop Flag Actuation E 103 E 113 Nurse Call 4000 Dual Single Status Push Button Emergency Station E 101 Push Button Emergency Station features a finish stainless steel faceplate with silk screened Stations can be used on single or dual status They may be flush mounted on a standard outlet box single gang rings or surface mounted on Wiremold 5748 or with a depth requirement of 1 Incandescent lamps not Field wiring terminations are with screw terminals for 16 gauge wire A touch of the push button type switch on the E 101 station activated a call for help verified by a red LED Calls can be cancelled by pushing the button again Push Button Emergency Station E 103 E 113 stations feature satin finish stainless steel faceplates with silk screened They may be flush mounted on Wiremold 5748 or equal with a depth requirement of 1 E 103 May be used with dual status systems Field wiring terminations are with screw terminals for 16 guage wire E 113 For single status only Wire lead terminations A touch of the DPDT switch button on the UL listed E 103 E 113 Emergency Station initiates an call verified by mechanical flag drop Calls may by cancelled by pushing the button again E 103 E 113 Emergency Stations The satin finish stainless steel faceplate with silk screened designations may be flush mounted a standard outlet box with single gang plaster ring or surface mounted on a Wiremold 5748 or Specifications The contractor shall furnish and install CORNELL Push Button Emergency as indicated on the plans Faceplates shall be satin finish stainless steel with silk screened Calls in progress E 101 are indicated by a red LED Calls in progress E 103 E 113 are by mechanical flag drop Calls may be cancelled by pushing the button again Stations shall be on standard outlet boxes with single gang rings or Wiremold 5748 or equal Information Power Requirements 24VDC Operating Environment 50 120 Indoor Non condensing Physical Faceplate Dimensions 4 x 2 Standard 1 Gang Mounting Single Gang back box with 1 minimum depth Wiring 22 AWG Minimum 16 AWG Maximum are only UL Listed in the 1 gang size in 1 6 gang sizes For correct part number change first number 1 to gang size needed

Related Files