Cornell Communications Time Delay Remote Control Station A-1801

File Preview
File Preview
Click below to download for free

Text Preview

Door Monitor 1000 Series Delay Remote Control Each station features a red LED to indicate armed when lit Single gang stainless steel faceplate suitable for or surface mounting A 1801 Remote Zone Controls with Time Delay provide personnel with alarm free access to individual zones in the A 1000 Door Monitor System Disarming is accomplished via the zone automatically resets to armed status after a preset time can be programmed for 5 60 seconds Tone option available on two gang plate The satin finish stainless steel faceplate with silk screened designations may be mounted on a standard outlet box with single gang plaster ring or surface mounted on a 5748 or equivalent Specifications The contractor shall install CORNELL A 1801 Zone Control with Time Delay as indicated on the plans for use with the Series A 1000 Door Monitor Each station shall provide alarm free access to authorized individuals using a key for control disarming Automatic reset shall follow a preset time delay Each single gang steel station suitable for flush surface mounting shall feature a key switch for and a red LED to indicate armed status when lit Power shall be supplied via the A 1000 master panel at 12 volts DC regulated Current is 17mA when zone is armed Information Power Requirements 12VDC Operating Environment 50 120 Indoor Non condensing Physical Faceplate Dimensions 4 x 2 1 Gang Mounting Single Gang back box with 1 minimum depth Wiring Terminations are Pigtailed in 1 6 gang sizes For correct part number change first number 1 to gang size needed