Ditek Surge Protection AE Design Specs

File Preview
File Preview
Click below to download for free

File Data

Name ditek-surge-protection-ae-design-specs-0698314752.pdf
Type PDF
Size 635.74 KB
Downloads

Text Preview

TABLE OF CONTENTS E DESIGN SPECIFICATIONS 2 16XXX SURGE PROTECTIVE DEVICES 2 1 GENERAL 2 SUMMARY 2 STANDARDS 2 ENVIRONMENTAL REQUIREMENTS 3 SYSTEM DESCRIPTION 3 OPERATING VOLTAGE 3 SUBMITTALS 4 QUALITY ASSURANCE 4 QUALIFICATIONS 5 FIELD MEASUREMENTS 5 COORDINATION 5 2 PRODUCTS 6 MANUFACTURERS 6 COMPONENTS 6 SYSTEM EQUIPMENT SPECIFICATIONS 10 and INTERCOM SYSTEMS 10 ALARM SYSTEMS 11 MANAGEMENT AND CONTROL SYSTEMS EMCS 12 SYSTEMS BURGLAR ALARM 12 DATA SYSTEMS 13 CIRCUIT TELEVISION SYSTEMS CCTV 14 TELEVISION SYSTEMS 15 CONTROLS SYSTEMS 16 EQUIPMENT 17 3 EXECUTION 17 INSTALLATION 17 MAIN SERVICE AND DISTRIBUTION EQUIPMENT SURGE SUPPRESSORS 17 VOLTAGE AND COMM DATA EQUIPMENT SURGE SUPPRESSORS 18 QUALITY CONTROL 19 Page 1 of 19 Rev 3 08 10 A E Design Specifications 16XXX Surge Protective Devices 1 specifications describe the electrical and mechanical requirements for a hybrid energy suppression filter system that integrates Surge Protective Devices SPDs high frequency electrical line noise filtering for high exposure applications specified unit s shall provide effective high energy transient voltage suppression current diversion and noise attenuation for all electrical modes of equipment downstream from a facility meter or main over current device in high ANSI IEEE C62.41 1991 category C B or A environments unit shall be designed and manufactured by a qualified manufacturer of surge equipment The qualified manufacturer shall have been engaged in the design and manufacture of such products for a minimum of ten 10 years specifications are based on DITEK Surge Protective Devices SPDs For other manufacturers shall provide detailed compliance or exception to all provisions of this specification fifteen 15 days prior to bid specified unit shall be designed manufactured tested and installed in compliance the following standards C62.33 Standard Test Specifications for Varistor Protection Devices C62.35 Standard Test Specifications for Avalanche Semiconductor Devices C62.41 1991 Recommended practice on Surge Voltages in Low AC Power Circuits C62.45 1987 Guide on Surge Testing for Equipment Connected to Voltage AC Power Circuits UL 1283 Standard for Safety Electromagnetic Interference Filters 1449 3rd Edition Revised September 2009 Standard for Safety Surge Devices NFPA 70 National Electrical Code NFPA 75 Standard for the Protection Electronic Computer Systems NFPA 780 Standard for the Installation of Lightning Protection Systems Military Standard Mil Std 220A Information Processing Standards Publication 94 FIPS PUB 94 CCITT Electrical Manufacturers Association NEMA LS1 1992 Guidelines Low Surge Protective Devices Page 2 of 19 Rev 3 08 10 REQUIREMENTS Storage Temperature temperature range shall be 40 to 85 C 40 to 185 F mounted devices may be 0 to 40 C 32 to 104 F Operating Temperature temperature range shall be 40 to 60 C 40 to 140 F mounted devices may be 0 to 40 C 32 to 104 F shall be operable within 0 to 95 non condensing relative humidity Relative Humidity Operating Altitude Audible Noise Magnetic Fields unit shall be capable of operation in altitudes up to 12,000 feet 3,658 meters sea level unit shall not generate any audible noise appreciable magnetic fields shall be generated Unit shall be capable of use directly computer rooms in any location without danger to data storage systems or devices DESCRIPTION Protective Devices SPDs are the equipment required for the suppression within limits of AC electrical circuits and electronic equipment from the effects of induced voltages external switching transients and internally generated transients Individual suppressors shall be installed as indicated on drawings nominal unit operating voltage and configuration shall be as indicated on the OPERATING VOLTAGE Page 3 of 19 Rev 3 08 10 Submit in accordance with Section 16XXX Basic Electrical Requirements

Related Files