DSC AE SPEC MAXSYS PC4020

File Preview
File Preview
Click below to download for free

File Data

Name dsc-ae-spec-maxsys-pc4020-3569421708.pdf
Type PDF
Size 629.59 KB
Downloads

Text Preview

AND ENGINEER SPECIFICATION 13850 DETECTION AND ALARM ACCESS AND SURVEILLANCE MAXSYS PC4020 V3.5 Rev0x2 Security Controls 3301 Langstaff Rd Concord ON Canada L4K 4L2 1 888 888 7838 30000091 R001 PC4020 13850 AND ALARM 1 GENERAL SUMMARY SECTION INCLUDES Control Panel Keypad Associated Equipment LISTINGS US Approvals ASSOCIATED SECTIONS 13703 Access Control 16721 Fire Alarm And Detection Systems 16750 Building Management Security Access Systems UNDERWRITERS LABORATORY UL UL864 Control Units System for Fire Protective Signaling System UL1610 Central Station Burglar Alarm Units UL609 Local Burglar Alarm Units and Systems UL365 Police Station Connected Burglar Alarm Units and Systems UL985 Household Fire Warning System Units UL1023 Household Burglar Alarm System Units UL High Line Security FEDERAL COMMUNICATIONS COMMISSION FCC Part 15 Radio Frequency Devices Part 68 Connection of Terminal Equipment to the Telephone Network Canadian Approvals CS03 IC Industry Canada UNDERWRITERS LABORATORY CANADA ULC ULC S527 Station Fire Alarm System Units ULC S303 Alarm Units Burglary ULC S304 Monitoring Station Burglar Alarm System Units PC4020 AND ALARM 13850 2 ULC S310 Burglar Alarm ULC S545 Fire Warning UL 294 Control ULC Level 5 International Approvals CE Europe CNC Argentina IRAM Argentina ACA Australia ANATEL Brazil INCERT Belgium NCP Netherlands SYSTEM OVERVIEW The system shall be a Burglary Fire Access Control integrated control panel with following capabilities Up to 8 System Partitions 1,500 User Codes 3,000 Event Buffer 34 Programmable Zone Types 61 Programmable Output Options Local And Remote Upload Download 99 Date Schedules 50 Arm Disarm Schedules 99 Open Close Suppression Schedules 50 Seismic Sensor Test Schedules 50 CTT Close Time Timer Arming Schedules Two Year Holiday Scheduling Automatic Daylight Savings Adjustment Expandable to 128 Zones Via Hardwire Wireless and 2 Wire Addressable Devices Add Up To 16 LCD Keypads Add Up To 64 Programmable Relays Add Up To 144 Low Power Outputs Add Point Graphic Annunciation UL ULC Listed For Residential And Commercial Applications Internet IP Communication 2 Way Communication Port RS 232 For Use with 3rd Party Software Remote System Administrator Software PC4020 AND ALARM 13850 3 2 PRODUCTS SYSTEM PERFORMANCE BASE PANEL security control panel shall have a base capacity of 16 fully and programmable zones with integral power supply and battery charger auxiliary power for powering security devices program switched auxiliary power supply for 4 wire detectors integral supervised digital alarm communicator two purpose program controllable outputs which can be programmed general purpose outputs or as Addressable loops and a supervised output PANEL ZONE EXPANSION panel shall be expandable to a maximum of 128 zones by adding hardwired 8 and or 16 zone modules connected to the base panel a supervised four wire power communication bus by adding up to 112 detection devices to one or both of the addressable loops on base panel or by adding 64 zone 433 MHz Narrow Band wireless to expand coverage area up to 8 receivers shall be supported to four wire communication bus The system shall be capable of using hardwired addressable and wireless simultaneously in mix that suits the application The system shall support hardwired sensors and programmable scheduled testing of these seismic SYSTEM KEYPADS system shall accommodate up to 16 LCD keypads which are powered the base panel via the four wire communications bus LCD keypads have a display capacity of at least 32 alphanumeric characters with display having brightness and contrast control Control keys shall be for low light level ease of use The keypads shall include and indicators and five buttons and three keypad activated alarm Keypads shall have the capability to operate in a power save in the event of a power failure FIRE MONITORING AND REPORTING system shall be capable of being easily expanded to provide local fire panel monitoring of alarm and trouble and reporting fire status using digital alarm communicators The dual digital alarm shall be fully supervised and automatically report line troubles and report alarms over the line PC4020 AND ALARM 13850 4 UL LISTED FIRE ALARM SYSTEM UL Listed commercial fire alarm version of the system shall have all capabilities of the alarm system with the following changes and base system panel shall be supplied in a red enclosure and be with a 16VAC 40VA transformer and a fire module complete 1 Class two wire smoke detector zone accommodating 30 smoke detectors 1 Class waterflow zone 2 supervised outputs terminal connection for house telephone 1 fire relay with Form contacts rated 2A 30VDC and one trouble actuated relay with Form contacts rated 2A 30VDC All shall be programmable as fire zones Addressable loops shall 112 smoke detectors programmed as standard fire zones or fire zones Hardwired fire zones shall be programmable as fire zones auto verify fire zones waterflow zones or fire zones All zones shall be supervised for open circuit and fault Addressable loops shall support supervised inputs for heat and pull stations System shall support 4 dual bell output panels the Combus each complete with red enclosure 2 supervised bell outputs supervised 350mA 24VDC battery charger 28VAC 170VA power transformer Bell outputs shall be supervised short circuit open circuit and ground fault Fire bell outputs shall be for 1.8A 24VDC each and be programmable as steady temporal CA pattern or pulsed Each bell output shall also be as a fire strobe output which will remain energized until system is reset Fire alarms shall autoscroll on all system LCD and fire silence and reset shall be limited by programming to access codes System software shall include the following test fire drill fire inspector test scheduled smoke detector tests annunciator lamp test Power supply relay output modules shall be in panels complete with a supervised 350mA 12VDC battery charger 40VA transformer and integral power supply to provide up to of auxiliary power at 12VDC to power direct connected devices or the Combus The system shall support fire specific annunciators providing annunciation of 10 fire zones 2 fire supervisory zones 1 bell zone trouble 1 common fire zone trouble 1 common system and 1 AC indicator ALTERNATE REPORTING METHODS system shall be capable of reporting all alarms trouble and system information over various combinations of the single integral digital communicator the dual digital alarm communicators a cellular an internet IP communicator and over a dedicated line channel PC4020 AND ALARM 13850 5 CENTRAL STATION REPORTING system shall provide high speed 20 bps 1400 2300 Hz handshake ID and SIA reporting formats and shall be capable of being to call up to 3 telephone numbers The system shall also communication to a pager The telephone numbers shall be for dialing should the primary number fail The shall be programmable for split reporting such that openings closing and miscellaneous events can be sent to telephone numbers or communication paths system shall report an account code for each partition and a separate code for non partition system e

Related Files