DSC HS2064-32-16-128 - Short Installation Guide - EN - v1-1 - R001
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-hs2064-32-16-128-short-installation-guide-en-v1-1-r001-2309481765.pdf |
---|---|
Type | |
Size | 1.50 MB |
Downloads |
Text Preview
This installation guide provides the basic wiring programming and troubleshooting information required to install the PowerSeries Neo alarm controller Use this guide in conjunction with the PowerSeries Neo Manual available online from the DSC website at www dsc com Available models HS2016 HS2032 HS2064 HS2128 Controller v1.1 Installation Guide the installation including all alarm detection devices expanders keypads and other required modules on a location for the alarm panel and secure it to wall using suitable mounting hardware all wiring including modules zones telephone line connections and ground Record module serial numbers on page 13 the battery and power up the system The battery be connected Wire the keypad to the Corbus power up the panel then press any button on the keypad Wire the HSM2Host to the Corbus then up the alarm panel and a wireless keypad Press button on the keypad to enroll it The HSM2Host is enrolled on the alarm panel Alternately enroll an keypad Code 902 subsection 000 Press to auto enrollment Module slots are automatically Use scroll keys to view slots Change slot by a 2 digit number Code 804 subsection 000 Note An or RF keypad must be enrolled first Setup Plan Mount Wire Power Enroll Enroll Enroll Test Program Basic programming 8 installer code 001 002 Type Zone Attribute 005 001 Partition 1 Entry Delay 1 Entry Delay 2 Exit Delay Phone 1 310 000 System Account the panel completely to ensure that all features and operate as programmed 901 Walk Test Wireless Placement Test Devices this document x in the model number represents the frequency of the device as follows 9 912 919 MHz 8 4 433MHz Only models operating in the band 912 919 MHz are UL ULC where indicated Only UL approved devices are to be used with listed systems 1 1 Compatible Devices keypads keypads with 2 way integration module keypads wireless integration Devices Devices expander expander supply high current output expander HSM2204UL communicator smoke detectors A B or C ULC listed models UL listed models European and Australian smoke detectors A B or C ULC listed models UL listed models European and Australian detectors PG smoke detectors PG smoke and heat detector PG CO detector PG PIR motion detectors PG PIR camera motion detector PG curtain motion detector PG dual tech motion PG mirror motion detector PG outdoor motion detector PG glass break detector PG shock detector PG flood detector PG temperature detector indoor use temperature probe requires PGx905 PG keys PG panic key PG 2 button key PG sirens PG repeater PG door window contacts PG door window contact w AUX I II III IV Station Receivers PC4050CR ULC Fire Monitoring PC4050CAR UL Commercial Burg CMC 1 UL Burg Other enclosures are available to suit a variety of system configurations This manual contains information on limitations regarding product use and function and information on limitations as to liability of the manufacturer The entire manual should be carefully read Neo Installation Guide Instructions for Service Personnel When using equipment connected to the telephone network always follow the safety instructions provided with this product Save these instructions for future Inform the end user of the safety precautions that must be observed when this equipment Installing The Equipment your package includes the following items and User manuals including the SAFETY INSTRUCTIONS and SAVE these instructions all WARNINGS AND INSTRUCTIONS specified within this document on the equipment HS2016 2032 2064 2128 alarm controller Power Supply direct plug in Mounting hardware A Suitable Location For The Alarm Controller the following list as a guide to find a suitable location to install this Locate near a telephone socket and power outlet Select a location free from vibration and shock Place alarm controller on a flat stable surface and follow the installation NOT locate this product where people may walk on the secondary cable s NOT connect alarm controller to electrical the same circuit as large NOT select a location that exposes your alarm controller to direct excessive heat moisture vapors chemicals or dust not install this equipment near water e g bath tub kitchen laundry wet basement near a swimming pool NOT install this equipment and accessories in areas where risk of exists NOT connect this equipment to electrical outlets controlled by wall or automatic timers interference sources installing equipment near heaters air conditioners ventilators and locating equipment close to or on top of large metal objects e g wall See Locating Detectors and Escape Plan on page 20 for information on loc smoke and CO detectors Precautions Required During Installation NEVER install this equipment and or telephone wiring during a lightning NEVER touch uninsulated telephone wires or terminals unless the telephone has been disconnected at the network interface Position cables so that accidents can not occur Connected cables must NOT subject to excessive mechanical strain Use only the power supply provided with this equipment Use of unau power supplies may cause damage For direct plug in versions use the transformer supplied with the device max voltages THIS EQUIPMENT HAS NO MAINS ON OFF SWITCH THE PLUG OF DIRECT PLUG IN POWER SUPPLY IS INTENDED TO SERVE AS THE DEVICE IF THE EQUIPMENT MUST BE QUICKLY IT IS IMPERATIVE THAT ACCESS TO THE MAINS PLUG AND MAINS SOCKET OUTLET IS NEVER OBSTRUCTED NOTE alarm system must be installed and used within an environment that provides the NON HAZARDOUS indoor only The equipment is DIRECT PLUG IN external transformer is designed to be installed serviced and or repaired by service persons only person is defined as a person having the appropriate technical and necessary to be aware of hazards to which that person may be exposed in a task and of measures to minimize the risks to that person or other persons are no parts replaceable by the end user within this equipment The wiring used for installation of the alarm system and accessories shall be insulated with TFE PTFE FEP Neoprene or Polyamide The equipment enclosure must be secured to the building structure before operation Internal wiring must be routed in a manner that prevents Excessive strain or loosening of wire on terminal connections Damage of conductor insulation Disposal of used batteries must be made in accordance with local waste recovery and regulations Before servicing DISCONNECT the power and telephone connection DO NOT route any wiring over circuit boards The installer is responsible to ensure that a readily accessible disconnect device is in the building for permanently connected installations power supply must be Class II FAIL SAFE with double or reinforced insulation the PRIMARY and SECONDARY CIRCUIT ENCLOSURE and be an approved acceptable to the local authorities All national wiring rules must be observed the Enclosure the panel in a dry area preferably near an unswitched AC power and the incoming telephone line Complete all wiring before AC or connecting the battery Descriptions following termina