DSC PC4010 v2 1 - Programming Manual - English - MAXSYS 8-64 Zone Control Panel

File Preview
File Preview
Click below to download for free

Text Preview

Table of Contents the PC4010 Toggle Options 2 HEX Digits 2 Manual 3 options 4 Messages 5 Options Toggle Options 7 Toggle Options 11 Lockout Options 12 Times 12 Supervision 12 Section Section Toggles 13 Options 14 Items Phone Numbers Communication Format Dialer Direction 15 Toggles 24 Miscellaneous 27 Code Transmission 27 Codes 27 Module 32 Auxiliary Output 34 Bell Output 35 Outputs PGM Output 36 Options 36 Options 36 Custom 37 Automation Items 37 Pulse Times 37 Outputs List 38 Options 41 Label 44 Scheduling 45 Edit Partitions Toggles 49 Times 51 Assignment 52 Type 52 Options 55 Label 55 Partition 56 Hardware Module 57 Module 58 Module 58 Zone Options 58 Zones Summary 60 Buffer 61 62 A of Available ASCII Characters 63 B of Diagnostics 64 PC4010 PC4010 incorporates a new method of programming which uses a menu system to find a specific program location it is to be entered 3 contains the programming flow charts for the PC4010 The charts are arranged in such a way as to allow you to find any option and the path required to arrive at the program location In addition you will be able to see other also available to you in the program area boxes are program areas and shaded boxes are menu selections methods may be used to select the different menu items to arrive at a program location With the first you may use arrow keys to scroll through the menu items When the desired item is displayed press the cid 81 key The cid 81 key used as an or key The panel will then move you to the next set of options other method incorporates a system Every menu and program item contains a one or two digit Simply press the number s in the menu or program box and the panel will automatically select the item for you NOT PRESS THE cid 81 AFTER ENTERING THE NUMBER This second method is much quicker once you familiar with it We wish to program the Exit Delay for Partition 4 The following is the flow chart located in Book 3 AREA to desired option using keys and press cid 81 AREA ADD EDIT PAR WHICH PARTITION cid 212 4 CUSTOMER ID CODE PAR TOGGLES PARTITION TIMES ENTRY DELAY EXIT DELAY select EXIT DELAY to select PARTITION TIMES to select EXIT DELAY cid 81 to select PARTITION TIMES cid 81 the first method the arrow keys would have to be pressed many times to scroll to the various items followed by the key to select the item Twelve keystrokes would be required after entering Installer Programming providing no are made The keystrokes required are as follows select PARTITION AREA cid 81 select ADD EDIT PAR cid 81 to select to PARTITION 4 the second method we require only 5 keystrokes to select PARTITION AREA to select ADD EDIT PAR to select PARTITION 4 less keystrokes required programming is quicker as there is less chance of an error occurring any time you may press the key to exit a section ANY DATA ENTERED WILL BE CHANGED THE KEY IS NOT ABORT KEY The key can also be pressed to move you back to the previous menu Pressing the key several will exit you from Installer Programming make programming easier the INDEX at the back of the Programming Manual includes the chart number beside every as well as the page number for a description of the option Toggle Options program areas contain several toggle options which pertain to the menu item selected Use the arrow keys to through the various items Press the cid 81 key to toggle between Y es and N o for each feature Once all the toggle have been programmed press the key to save your changes and return to the previous menu HEX Digits HEX digits are required for a program item When a HEX digit is required press the cid 81 key to enter the HEX menu may use the arrow keys to scroll through the HEX digits A through F and when the desired letter is displayed press cid 81 key much quicker method for entering HEX digits is to first press the cid 81 key followed by the number corresponding the HEX letter i e A 1 B 2 C 3 up to F 6 The cid 81 key must be pressed before entering each HEX digit as the returns you to decimal programming automatically after each entry To enter data on a PC4010 you would enter 1 cid 81 2 cid 81 3 cid 81 4 The cid 81 key is required before every HEX digit entered PC4010 Installer Programming is broken down into 5 major sections Area For programming options which affect the operation of the entire system For example communications printer options etc are options which affect the overall system and are programmed in the system area Area For programming options which pertain to individual partitions For example the zone assignment entry time and exit delay time are all options which can be programmed for each of the partitions Hardware For enrolling and deleting modules Buffer For the installer to reprint the entire event buffer For viewing trouble conditions reported by the modules AREA MAIN BELL OUTPUT 35 INSTALLER OPT EVENT MESSAGES SYSTEM OPTIONS DLS SECTION COMMUNICATOR SW AUX OUTPUT PGM OUTPUTS PC4400 OPTIONS SYSTEM LABEL EVENT SCHEDULING ADD EDIT PAR DELETE PARTITION COPY PARTITION ENROLL MODULE DELETE MODULE CONFIRM MODULE RF ZONE OPTIONS PR

Related Files