DSC PC5108L v1 1 IM EN NA

File Preview
File Preview
Click below to download for free

File Data

Name dsc-pc5108l-v1-1-im-en-na-4037615928.pdf
Type PDF
Size 701.51 KB
Downloads

Text Preview

Installation Digital Security Controls Ltd Canada cid 127 www dsc com Support 1 800 387 3630 in Canada 29005040 R002 all comments and sugges concerning DSC publications pubs dscltd com refer to the System Installation Manual for information on regarding product use and function and information on the as to liability of the manufacturer v1.1 R O G R A M M N G W O R K S H E E T S Camera Test Configuration 1 Camera 1 Test Enabled 2 Camera 2 Test Enabled 3 Camera 3 Test Enabled 4 Camera 4 Test Enabled 5 Camera 5 Test Enabled 6 Camera 6 Test Enabled 7 Camera 7 Test Enabled 8 Camera 8 Test Enabled 1 Test Disabled 2 Test Disabled 3 Test Disabled 4 Test Disabled 5 Test Disabled 6 Test Disabled 7 Test Disabled 8 Test Disabled Restore Module Factory Default Programming 55 in this section to restore the PC5108L to its factory default WARRANTY WARRANTY WARRANTY WARRANTY WARRANTY Security Controls Ltd warrants that for a period of twelve months from the date of purchase product shall be free of defects in materials and workmanship under normal use and that in of any breach of such warranty Digital Security Controls Ltd shall at its option repair or the defective equipment upon return of the equipment to its factory This warranty applies to defects in parts and workmanship and not to damage incurred in shipping or handling or due to causes beyond the control of Digital Security Controls Ltd such as lightning exces voltage mechanical shock water damage or damage arising out of abuse alteration or improper of the equipment foregoing warranty shall apply only to the original purchaser and is and shall be in lieu of any all other warranties whether expressed or implied and of all other obligations or liabilities on the of Digital Security Controls Ltd This warranty contains the entire warranty Digital Security Ltd neither assumes responsibility for nor authorizes any other person purporting to act on behalf to modify or to change this warranty nor to assume for it any other warranty or liability this product no event shall Digital Security Controls Ltd be liable for any direct or indirect or consequential loss of anticipated profits loss of time or any other losses incurred by the buyer in connec with the purchase installation or operation or failure of this product Digital Security Controls Ltd recommends that the entire system be completely tested a regular basis However despite frequent testing and due to but not limited to criminal tamper or electrical disruption it is possible for this product to fail to perform as expected COMPLIANCE STATEMENT Changes or modifications not expressly approved by Digital Security Controls could void your authority to use this equipment equipment generates and uses radio frequency energy and if not installed and used properly strict accordance with the manufacturer instructions may cause interference to radio and reception It has been type tested and found to comply with the limits for Class B in accordance with the specifications in Subpart of Part 15 of FCC Rules which are to provide reasonable protection against such interference in any residential However there is no guarantee that interference will not occur in a particular If this equipment does cause interference to television or radio reception which can determined by turning the equipment off and on the user is encouraged to try to correct the by one or more of the following measures Re orient the receiving antenna Relocate the alarm control with respect to the receiver Move the alarm control away from the receiver Connect the alarm control into a different outlet so that alarm control and receiver are on circuits necessary the user should consult the dealer or an experienced radio television technician for suggestions The user may find the following booklet prepared by the FCC helpful to Identify and Resolve Radio Television Interference Problems This booklet is available the U S Government Printing Office Washington D C 20402 Stock 004 000 00345 4 Class B digital apparatus meets all requirements of the Canadian interference causing regulations appareil num de la Classe B respecte toutes les exigences de r sur le mat du Canada R O G R A M M N G W O R K S H E E T S Zone 27 Zone 28 Zone 29 Zone 30 Zone 31 Zone 32 Keypad Alarms Closings Openings Periodic Test TX Gen Sys Tamp System Test Pre Trigger Remote Trigger T PC5108L 1st Control Options 1 Camera Monitor When Disarmed 2 Camera Monitor When 3 Camera Monitor When 4 External Dwell Control SYNC 5 Fast Dwell Time 3s 6 Sync Input Is Inverted 7 Images Can Be Overwritten 8 DLM 4L Not Used PC5108L 2nd Control Options 1 New Events Do Not Abort Active Video Session 2 8For Future Use When Disarmed When When Dwell Control Dwell Time 6s Input Is Normal Cannot Be Overwr is connected Events Abort Active Video Session Features PC5108L serves three purposes To expand the PC5015 v2.2 alarm control panel zone capability by eight fully programmable zone inputs Zone expansion using this module is not available on the v3.0 and above To act as an interface between the DLM 4L v1.0L Video Transmission and the PC5015 v2.2 and PC5020 v3.0 and above alarm panel To function as a video switcher Specifications Current rating 60mA Eight fully programmable zones PC5015 v2.2 only Maximum of eight video cameras VAUX rating 12 VDC fused 250mA Additional Equipment Control panel compatibility PC5015 v2.2 PC5020 v3.0 and above Downlook module compatibility DLM 4L v1.0L Keypad compatibility for Active Camera Monitor Selection function LCD5500Z v2 X and above and PC55XX v2 X Downloading software DLS 3 v1.2 and above Local downloading PC Link Compatible cabinets space for PC5108L plus two other modules of same Unpacking the PC5108L PC5108L product should include the following items one PC5108L module five plastic stand offs Mounting the Unit Wiring the Unit PC5108L should be located inside a compatible metal cabinet in a dry secure location Preferably it should be placed close to control panel and at a convenient distance from the connected

Related Files