Edwards 5530MD-24AW Installation Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | edwards-5530md-24aw-installation-instructions-9647385120.pdf |
---|---|
Type | |
Size | 874.74 KB |
Downloads |
Text Preview
Adaptatone Millennium Signal Sheet ES FR PT 5530MD 24AW can be mounted to any flat surface or may used as a freestanding appliance mounted to a rigid pipe 5530MD 24AW must be installed in accordance with the edition of the National Electrical Code or other applicable to the country and locality of installation by a trained and qualified electrician To prevent fire shock and component damage not service the appliance or remove the circuit board while circuit is energized Any kind of service or maintenance performed while the is energized voids the warranty mount the 5530MD 24AW Mount the 5530MD 24AW as shown in Figure 1 Flat Surface Mounting Secure the unit to the surface using the four mounting holes in the plate on the rear of the box Use the 3 in 76 mm wood screws furnished loose or hardware not supplied suitable for the surface Rigid Pipe Mounting Loosen the four cover screws the signal box and remove the signal box cover Cover screws are captive Do not remove them the cover the center knockout in the lower wall of the and mount the box to a 1 2 in 12.7 mm conduit using a suitable connector the wires through a knockout hole in the bottom of box from a raceway that is approved for the same of protection and enclosure type required by the Do not change factory applied finishes Installation Sheet 5530MD 24AW Adaptatone Millennium Signal is a diode polarized tone selectable indoor outdoor Type 3R audible signaling appliance primarily intended use in fire alarm systems and other applications requiring supervision of signaling circuit field wiring The is UL and cUL Listed as audible signal for use in the following hazardous locations number code locations I Div 2 Groups B C D II Div 2 Groups G Class III Div 1 2 100 5530MD 24AW is activated and powered by a fire alarm notification appliance circuit NAC or other supervised VDC source and sounds a high decibel signal determined the setting of configuration switches inside the appliance 5530MD 24AW may be configured for any of the tones in Table 1 The speaker direction and output level are adjustable 2012 UTC Fire Security All rights reserved 24 3100007 REV 07 ISS 02JUL12 1 Mounting Speaker Large star nut to adjust direction Signal box Cover screws 4X Collar gaskets 4X Raceway and connection not to 1 2 in mm knockout hole 10 3 in 76 mm screws or hardware suitable for the surface 4X Mounting plate Risk of death or serious injury To prevent fire and wire the 5530MD 24AW only as described in this sheet Equipment damage hazard To ensure proper of connections do not use looped wires under screws Break the wire run Use both sides of the screws as shown in Figure 2 Terminal block TB1 can be unplugged from the main to complete the wiring as shown in Figure 2 Wire the 5530MD 24AW to a supervised signaling circuit follows Connect the green ground and yellow striped earth wire to earth ground Connect the incoming power to TB1 1 and TB1 2 as in Figure 2 Polarity must be observed Connect the wires leading to the next signal or end of resistor to TB1 1 and TB1 2 as shown in Figure 2 must be observed Set the miniature programming switches on the input Refer to Figure 3 and Table 1 to select desired Risk of death or serious injury High voltage is when the appliance is energized High volume may harm to personnel in close proximity Adjust the volume level if desired by turning the located on the motherboard as shown 3 Equipment damage hazard To ensure the integrity of 5530MD 24AW assembly when adjusting the speaker make sure the threads in the enclosure remain fully and do not turn the speaker more than 360 degrees the original factory installed position To adjust the speaker direction loosen the large star nut Figure 1 and turn the speaker to the approximate position Retighten the nut and turn the speaker clockwise until it is locked into place damage hazard Ensure that the cover gasket part P 007549 0069 is adhered into the groove at the perimeter and that the four collar gaskets part number are in place on each cover screw before the signal box cover damage hazard When securing the cover start the by hand making sure they are threaded into the tapped in the housing bosses before securing with a Torque signal box cover screws to a minimum of in lbs This ensures the required tight fit Secure the signal box cover using the four retained cover Torque the signal box cover screws to a minimum 20 in lbs Verify operability Risk of death or serious injury To prevent fire and component damage no work including circuit removal should be performed while the circuit is Any kind of service or maintenance performed while the is energized will void the warranty the unit semi annually for accumulation of dirt Clean necessary 5530MD 24AW should be tested annually or as required the authority having jurisdiction to ensure continuous 24 3100007 REV 07 ISS 02JUL12 2 Wiring to terminal block TB1 To next signal or end of line resistor From control panel signal circuit Terminal block TB1 Main board Polarity is reversed in supervisory or standby condition 3 PC board locations board jumpers factory installed board Programming switch SW4 on other side Main board Potentiometer for volume adjustment Processor board 3100007 REV 07 ISS 02JUL12 24 1 Tone programming Tone SW4 5 SW4 4 SW4 3 SW4 2 SW4 1 Description Whoop 1 Whoop Siren Horn Tone 2 Blind Mice Tone Alert Whoop Pulse Horn 1