Edwards ANSZS2A 4B Zone Splitter Install

File Preview
File Preview
Click below to download for free

File Data

Name edwards-anszs2a-4b-zone-splitter-install-3507468291.pdf
Type PDF
Size 736.83 KB
Downloads

Text Preview

and ANSZS4B Zone Splitter Sheet Do not leave a zone switch turned on when as this leaves the zone unsupervised an alarm state the ANSZS2A and ANSZS4B default to All operation On activation of the ANS voltage all zones are automatically selected and receive the tone and message Modules have a field selectable for alarm zone activation only if the FACP has the ability provide separate pull down inputs a zone has a short fault a PTC thermistor for the zone excluding the zone from output and allowing the other to continue operation Once the short is removed the line must be disconnected for 30 seconds to reset the 24 Vdc 45 mA All Call 130 mA trouble relay TB2 7 8 and 9 rating 1 A at 30 Vdc resistive load Restricted to Class II or power limited Interconnected equipment is unsupervised so it be in the same room and mounted within 20 feet of module circuit EOL 10 k description ANSZS2A and ANSZS4B Zone Splitter modules are for use with the ANS25 ANS50 and ANS100 Audio Systems Their purpose is to enable the output of ANS to be split into multiple zones for paging and alarm modules accept input from the ANS speaker output and selectable output relays to distribute the output to the zones The modules can be cascaded to increase number of zones modules provide supervision of the individual zones for and short conditions Indicator LEDs display active or conditions for the individual zones A fault condition is to the FACP through the same supervisory path as ANS25 ANS50 or ANS100 can be selected manually by switches or through pull inputs In the event of an alarm condition the module to All Call operation The All Call feature can only be if the accompanying panel has zone control zone is limited to no more than 25 W and the total load must not to exceed the output rating of the ANS output can be set to 25 or 70 Vrms selected by a position on the ANS25 ANS50 or ANS100 normal standby the ANSZS2A and ANSZS4B supervise speaker zone wire loop The ANSZS2A provides Style Y and the ANSZS4B provides Style Z supervision an open or short fault is detected in a zone the yellow for that zone turns on A NC relay contact opens to a corresponding fault signal to the FACP providing of the ANS faults in zone circuits are not reported by the or ANSZS4B but are detected and reported by the ANS50 or ANS100 manually select a zone the operator turns on the zone switch The red LED for the switch lights output relay activation is enabled On activation of the PTT from the ANS the output relay connects the zone to the speaker output While the zone is selected supervision is 2013 UTC Fire Security All rights reserved 4 3101185 REV 02 REB 28FEB13 and functions 1 shows the location of the terminal blocks zone switches configuration jumpers and PTCs This describes the functions of each component 1 Features of the ANSZS2A and ANSZS4B cards 2 3 4 5 6 7 1 Terminal descriptions output terminals at either 25 or 70 Vrms per setting Output terminals for four zones Class B Z Output and return terminals for two zones A Style Y ANSZS4B source source push to talk signal 1 output 1 output 1 return 1 return 2 output 2 output 2 return 2 return 1 output 1 output 2 output 2 output 3 output 3 output 4 output 4 output 4 to 7 Vdc power supply active signal negative trouble relay N O 1 trouble relay C trouble relay N C circuit input circuit input circuit output or EOLR circuit output or EOLR zone activation pull down 2 Call activation 4 activation 3 activation 2 activation 1 activation See for more information on the Aux trouble relay See J1 settings under for optional zone activation S1 through S4 provide manual zone activation when operator is in attendance Switch S5 activates all zones All on all interconnected ANSZS2A or ANSZS4B zone Switching S5 on any zone splitter generates an all call all zone splitters in the system Do not leave a zone switch turned on when as this leaves the zone unsupervised 2 Switch descriptions 1 activation 2 activation 3 activation 4 activation Call activation 3 Jumper settings zone activation on alarm active 0 Call operation on alarm active activation using pull down inputs on TB3 3101185 REV 02 REB 28FEB13 thermistors 1 shows the locations of the PTCs PTC 2 4 6 and 8 output protection for speaker zones 1 2 3 and 4 Each PTC is installed in a socket for easy ANSZS2A and ANSZS4B are shipped with PTCs for Vrms operation These are labeled 075 For 25 Vrms leave these PTCs installed configure the module for 70 Vrms operation replace all four with the optional PTCs provided These are labeled 040 state and local codes instructions that all wiring and devices installed in the system meet following standards NFPA 70 National Electrical Code NFPA 72 National Fire Alarm and Signaling Code NFPA 101 Life Safety Code this equipment in a clean dry environment Avoid where the equipment could be subjected to Remove all electronic assemblies from the enclosure drilling or punching the enclosure Where possible all cable entries from the rear or sides Before making modifications to the enclosure be certain that they will not with the assemblies or batteries all field wiring use FPL FPLR or FPLP as required per 70 Article 760 wiring shown in diagrams is power limited diagrams 2 ANSZS4B typical wiring 2 3 4 5 6 7 50 100 OUT ACT NEG SET 1 ZONE SPEAKER IS B Style Y wiring 1 2 3 4 kO EOLR 2 3 4 5 6 7 2 2 3 4 5 6 7 ACTIVATION INPUTS 1 2 3 4 CALL This resistor sets the amplifier end of line value only The and ANSZS4B must use 10 k EOLRs Break the wire run at each terminal to maintain supervision Do loop the wire around the speaker terminal 3101185 REV 02 REB 28FEB13 4 3 ANSZS2A typical wiring for multiple units ANS25 or ANS100 ZONE SPEAKER IS A Style Z wiring 2 3 4 5 6 7 2 3 4 5 6 7 2 3 4 5 6 7 1 2 3 4 5 6 7 2 1 Break the wire run at each terminal to maintain supervision Do loop the wire around the speaker terminal 10 k EOLR Additional units can be daisy chained in the same fashion Ensure EOLRs are installed at the last Zone Splitter to maintain 4

Related Files