Faraday - MPC-1500 Fire Alarm Control Panel Data Sheet

File Preview
File Preview
Click below to download for free

File Data

Name faraday-mpc-1500-fire-alarm-control-panel-data-sheet-5172840693.pdf
Type PDF
Size 619.87 KB
Downloads

Text Preview

Effective October 30 2000 replaces April 1 2000 Analog Addressable Conventional Fire Alarm Control Panel Two analog addressable SLCs 396 pts to four 792 pts Four NACs style Y Class B expandable 12 convertible to style Z class A Expandable to add up to 8 IDCs style D B 4.5 amp power supply 3 amps for NACs 80 character backlit LCD with custom labeling LEDs for panel status indication Connection for 16 remote 80 character display LCD annunciators backlit on activation Optional DACT connection or internal DACT Fully field programmable via PC removable and automatic programming 2000 event history log in nonvolatile memory Dynamic quick test function by device or the panel Drift compensation alarm verification Day Night sensitivity mode NFPA 72 sensitivity testing Manual alarm silence with 0 1 3 or 6 minute inhibit Auto silence selectable for each NAC 10 20 or 30 or none Silent or audible Quick Test Local energy shunt or polarity reversal city tie circuits Coded output Two password levels Tech Maintenance Transient protected UL Listed standard 864 CSFM listed MEA MPC 1500 is an advanced modular fire alarm It features analog addressable detection and memory capability and is capable of special expansion modules to allow the of up to 8 local conventional style D B zones It base configuration includes two loops with four conventional appliance output circuits controls and indicators are mounted on the with a mylar label for identification An 80 LCD display provides specific indications for devices and conventional expansion while LEDs indicate general panel status 240 Software zones 255 notification and 255 relay Configuration main termination board mounts in the rear of the The main power supply is physically contiguous the main termination board The MPC 1500 main board provides the interface for external system connections a platform for the loop board four signaling circuits remote signaling and indicating interfaces and the electronics of main system power supply Expansion termination mount in the rear of the control panel above main board They provide the interface for an loop driver board and conventional zone boards expanding the capability of the panel two loops unneeded loop capability need not be in to four loops and eight conventional zones in the extended cabinet Each loop signal board also provides four more signaling and each conventional expansion termination provides two more signaling circuits for a maximum of 12 continued 1 Addressable Conventional Fire Alarm Control Panel front main logic PCB mounts on the cover of the allowing it to carry the controls and displays which be accessible from the front panel The system and low level logic are included on this to leave the power handling to the heavier in the back of the box Since displays for any of zones handled through board no of this is required for 07 09 98 Status Display Normal Power ON p Reset Silence Silenced Silence Acknowledge normal operation controlled from front of the via push switches and enabling key required for functions except of the most active event Displays are provided by an 80 alphanumeric backlit LCD display and by LED indicators for major panel functions MPC 1500 Control Unit Before Servicing Alarm 80 character LCD display is used to display event including alarms and troubles identification of or device and presentation of history The is controlled by a set of four push button commanding the control processor Opera of the key switch is required to call up any but the recent active event A back light is included in the to assure visibility in low light but to conserve it is only activated during a reported event or of a display control switch Control Unit Configuration Addressable Input Output Circuits addressable main termination board mounts addressable loop interface board supporting two device communication loops Notification Appliance Circuits base panel has four independent NACs Each can be selected to give continuous output or of eight sounding patterns available Dry Contacts Five dry relay contacts are These contacts are dedicated to alarm supervisory AC failure and processor indications City Tie The city tie circuitry is located the main termination PCB Shunt local energy polarity reversal mode may be selected by of a programming header Only one mode only one output may be selected The output be alarm trouble supervisory or trouble Digital Dialer Output The main board provides a standard DACT providing system event data to a receiving station Remote Annunciation The MPC 1500 panel drive up to 16 annunciators RDC 1 and 8 processors SAU 1 SRU 1 on an communication line Power Supply A 4.5A 24V nominal power provides all operating power to the panel for standby and alarm conditions Control Unit Configuration Addressable Loop Signal Exp Board LSE 1 of an expansion termination board for another addressable loop interface supporting two addressable loops Only one expansion board may be used Conventional Expansion Board CEB 1 IDCs may be included in the system adding one or two conventional expansion boards Each board provides 4 initiating which can be converted to class by the addition of a class A adapter board CEB 1 board also includes two notification circuits Each group of two notification circuits may be powered by separate provided 24 Vdc if desired DACT Expansion Module DEM 1 The DEM 1 a dual line digital alarm communications It parameters are set via the control programming sequence The DEM 1 may be in the main enclosure An extended is required if more than one expansion is to be used DEM 1 is compatible with the following SIA DCS 8 SIA DCS 20 Ademco Contact 3 1 1400 Hz 3 1 2300 Hz 4 2 1400 Hz and 2300 Hz 2 Addressable Conventional Fire Alarm Control Panel Devices Remote LCD Annunciator RDC 1 The remote annunciator consists of a backlit 80 character display 4 menu buttons 4 dedicated for operator interaction 6 LED indicators a security key switch Serial Annunciator Unit SAU 1 The remote is used with LED or incandescent modules to perform programmed Main Termination Board Serial Relay Unit SRU 1 Each remote relay contains eight 3A form C relays Each processor board can then address up to 24 The MPC 1500 panel will control eight for a total of 192 relay addresses but 100 maximum addresses may be used at one in the system or 240 Supply to TB14 DG O A O A O A C A Tie Trouble rated 2A 30 Vdc 5A Vac resistive MON PWR Trouble Limited 1 2 3 4 ohm rated 1.5A max Power Input connections remote printer connections remote LCD processors connections SLC loop 1 loop 2 Pwr max 24 Vdc Specification

Related Files