Faraday - MPC-2000 Fire Alarm Control Panel Data Sheet

File Preview
File Preview
Click below to download for free

File Data

Name faraday-mpc-2000-fire-alarm-control-panel-data-sheet-3697512804.pdf
Type PDF
Size 618.09 KB
Downloads

Text Preview

Effective January 1996 Addressable Fire Alarm Control Panel UL listed file no S405 standard 864 power CSFM listed no 7165 0065 123 BSA approved calendar no 524 77 SA under the FM listed no OV7A2 AY Configurable for NFPA 71 72 systems UL listed for NFPA 72E testing and drift of addressable analog smoke Microprocessor controlled Modular construction Non coded or zone coded Expandable to 104 input zones and 96 output Expandable to 1584 analog addressable points Expandable up to 30 amps of combined regulated unregulated 24VDC system power Supervised inter module data links Custom programming field design flexibility Programmable from laptop computer Both conventional and analog addressable system displays and controls with expanded software system status 32 character backlighted alphanumeric system status display User friendly display programming and control Manual automatic waterflow and supervisory monitoring capabilities Alarm verification 1 person quick test and drill programming formats Extensive built in transient protection CRT compatible Event hard copy record compatible DMO degraded mode operation Made in USA ISO 9001 quality crafted 1 3 Window Cabinet MPC 2000 Fire Alarm Control Unit provides a of modular building blocks and software pack to construct a variety of configurations of hard non coded zone coded and fire alarm control systems The of standard modules along with a wide selection software gives the MPC 2000 the maximum versatil for the most demanding field requirements The can be configured to meet most common state and local codes The combinations of solid state function modules high performance control and expanded software work to make the MPC 2000 a versatile durable serviceable system control unit MPC 2000 consists of basic function modules a controller and system software which may be configured in limitless numbers of to allow for custom tailoring of each panel for specific and changing building fire system requirements Along with the above the MPC 2000 offers surface mounting continued Addressable Fire Alarm Control Panel minimum complete analog addressable control must include Choice of control unit cabinet Choice of battery cabinet Choice of appropriate sized battery CU 2 main CPU control display unit MP 3 main power supply module BC 2 battery charger module TX 1 transformer modules AP 5 signal power supply module BB 2 buffer board module AM 1 analog addressable loop module Appropriate number of BK 1 blank modules additional requirements and features specified may be satisfied by including various combinations of and or function modules and software packages in the following pages Cabinetry R Red B Black Window 28 Module and 4 transformer spaces box 27 17 32 H x 27 W x 5 11 16 D Door 27 25 32 H x 27 1 4 W x 1 2 D Door 29 5 32 H x 29 W x 1 4 D R or B Universal Back Box R or B Surface Door hinged on left R or B Surface Door hinged on right R or B Flush Door hinged on left R or B Flush Door hinged on right Window 42 Module and 4 transformer spaces box 36 3 16 H x 27 W x 5 11 16 D Door 36 7 16 H x 27 1 4 W x 1 2 D Door 37 13 16 H x 29 W x 1 4 D R or B Universal Back Box R or B Surface Door hinged on left R or B Surface Door hinged on right R or B Flush Door hinged on left R or B Flush Door hinged on right and true flush mounting cabinets which are configured for multiple cabinet installations required Matching surface or semi flush system battery cabinetry is also available With all of versatility the MPC 2000 can be expanded from a conventional two zone system to the most multi zone or analog addressable multifunc control system and convenience features have been engi into the MPC 2000 to provide the capability for most complex system control and information and recording needs without sacrificing of operation and data retrieval The end is maximum system performance with maximum friendliness and modular construction allows each unit to be tailored for versatility serviceability simple operation No components are mounted on cabinet doors assuring economical expansion or in the field without rework of existing and cabinetry MPC 2000 is intended for use in the medium to commercial institutional and industrial applica With it wide variety of function modules and powerful microprocessor control the will provide an economical and versatile package for a wide selection of applications any control panel basic functions must be in the unit to comply with basic UL and NFPA minimum complete conventional MPC 2000 must include Choice of control unit cabinet Choice of battery cabinet Choice of appropriate sized battery CU 2 main CPU control display unit MP 3 main power supply module BC 2 battery changer module TX 1 transformer modules AP 5 unregulated power supply module BB 1 buffer board module Choice of ZN 1,2,3 dual zone module Choice of SC 1,2,3 dual signal module number of BK 1 blank modules Appropriate number of BK 1 blank modules 2 Addressable Fire Alarm Control Panel Cabinets R or B Surface cabinet x 27 1 4 W x 8 57 64 D R or B Semi flush trim ring for BE 1S x 30 1 8 W R or B Surface Cabinet x 14 3 8 W x 5 D R or B Semi flush trim ring for 14050 17 1 x 17 1 2 W Control Modules Central Processing Unit Includes control assembly with key pad system indicators 32 character alphanumeric back lighted status Switches Provided System Reset Alarm Trouble Silence Circuit Cutoff Drill Test Lamp Test Program System Enter Back Skip No Down Yes Up Indications Provided Green Power On System Alarm Amber Alarm Silenced Trouble Trouble Silenced Input Power Standby Power Fault System Ground and Fault LEDS Also 32 character backlighted display for standard or custom loaded system and trouble status readouts Normal display is and date Draw none contained in MP 3 figures Required 5 module spaces Weight 1.5 lbs Power Control Buffer Module Provides means power and control distribution to control unit conven initiation and signaling option modules 1 BB 1 is required for each conventional communica channel used within the control unit i e input and A header for linking an additional buffer within a communication channel group is on the module Switches Provided none Indications Provided none Draw Alarm 006A Standby 006A Required 1 module space Weight 1.0 lbs Control Buffer Module Provides means of distribution to control unit AM Cl SI and PR modules 1 BB 2 module is required when the communication channel is used within control unit i e printer serial drive analog or remote computer functions Each module has the capacity to buffer the full of printer parallel modules up to 1 PR AM 1 SI and 2 Cl modules Total of 10 mod Switches Provided none Indications Provided none Draw Alarm 110A Standby 006A Required 1 module space Weight 1.0 tbs Main Power Supply Module Provides a battery means of supplying up to 1.5 amp of filtered non resettable and 1.5 amp resetable power limited operating power for control unit and or detection devices Module be paired with 1 2 TX 1 transformer filtered Switches Provided none Indications provided none Draw Alarm 110A Standby 100A Required 2 module spaces Weight 2.0 tbs Regulated Auxiliary Power Supply Module a battery backed means of supplying up to amp 24VDC of filtered regulated resettable 1.5 amp 24VDC non resettable system operat power for the MPC 2000 This power i

Related Files