Fenwal Supression Panels 2320 Series

File Preview
File Preview
Click below to download for free

File Data

Name fenwal-supression-panels-2320-series-5293104867.pdf
Type PDF
Size 1.11 MB
Downloads

Text Preview

2320 Fire Suppression Panel Status Indicating LEDs Diagnostic LEDs Microprocessor Based Multiple Abort Releasing Modes Programmable Alarm Relay Single or Dual Solenoid Release Programmable Delays Programmable Release Circuit Isolate Programmable Cross Zone Operation Supervised Abort Manual Release and Supervisory Hour Trouble Resound Release and Noise Protection UL FM ULC MEA CSFM 2320 is a low cost control panel that supervises and one fire suppression hazard Microprocessor enhances reliability and field programmable The control unit is compatible with Fenwal clean agent suppression systems It meets of NFPA 72 and addition to extensive approved for use in suppression systems cov by NFPA codes 12 12A 17 17A and 2001 control panel provides 14 indicating status LEDs and diagnostic LEDs Indicating status LEDs are Manual Release Alarm and Trouble LED indications are Ground Fault Fault Circuit Open Circuit Short Power 1 Alarm and Trouble 2 Alarm and Trouble Silence ON Trouble Trouble Output Trouble Active and Trouble Fault May 2007 Systems UTC Fire Security Company multiple programmable options 3 abort modes single or cross zone operation circuit isolation and a second alarm relay pro to operate on actuation of 2nd cross zone or release abort modes are Mode 1 Timer hold at 10 seconds count down Mode 2 Timer reset to initial value count down abort release abort release Mode 3 Timer hold at 10 seconds if actuated before alarm count down upon abort release IRI 2320 has two independent style initiating circuits can be programmed for single or cross zone applica The circuits support 15 Fenwal 2 wire CPD PSD smoke detectors which can be intermixed with contact type rate compensated ther detectors Also style abort manual release and circuits are provided All input circuits permit to 50 ohms resistance thus allowing extended wiring manual release and audible visual signal can be panel mounted with P N 30 232001 001 or P N option see ORDERING The manual release switch incorporates a lift type to prevent inadvertent activation style signal circuit is rated 0.5 Amps 24 Vdc Power or 240 Vac or 0.25 Amp maxi Requirements mA mA Power amps 24 Vdc in alarm only Circuits Input Circuit Outputs Output style 50 ohms 10K EOL Supervisory Manual Release Abort style 10K EOL style 0.5 Amp 24 Vdc EOL alarm one trouble form 2 Amp 24 Vdc 2nd alarm programmable Operation Activate one or two P N 48650001 890181 or one of P Ns 93 or 87 120099 001 Output Activate up to six P N 93 191001 or up to ten P N 31 199932 004 Switch Disconnects Release Output Delay to Dis only selectable 0 to 30 seconds in second increments in H x 11 in W x 2 5 16 in D Control Unit is capable of activating the following devices One or two 24 Vdc Solenoid Control Head P N One or two 24 Vdc Solenoid Control Head P N One set of up to ten P N 31 199932 004 initiators One set of up to eight P N 31 199932 012 initiators One set of up to six P N 93 191001 001 initiators One CXV 24 Vdc Solenoid Control Head One XV 24 Vdc Solenoid Control Head 93 487100 001 87 120099 001 Effective September 1996 P N 31 199932 012 for Bottom Discharge Cylinders has replaced by P N 93 191001 001 control panel 24 Vdc power supply for 120 or 240 Vac input electronic power overload protection and built in battery charger panel mounted 1.2 AH batteries P N 06 provide 24 hours of standby followed by five alarm operation ORDERING INFORMATION for optional Canadian versions INFORMATION Number Control Panel UL 120 Vac Control Panel UL 240 Vac Control Panel ULC 120 Vac Control Panel ULC 240 Vac Panel Option w o audiovisual Panel Option w audiovisual Control Panel UL 120 Vac premounted 30 232001 002 12 Vdc 1.2 Ah 2 required Kit 50 10K EOL resistors literature is provided for informational purposes only KIDDE FENWAL INC no responsibility for the product suitability for a particular application The prod must be properly applied to work correctly you need more information on this product or if you have a particular problem or ques contact KIDDE FENWAL INC Ashland MA 01721 Telephone 508 881 2000 Rev AB 2007 Kidde Fenwal Inc in USA Systems UTC Fire Security Company Main Street MA 01721 508.881.2000 508.881.8920

Related Files