Fike D 1 03 01 FACP (GP-5UD) Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fike-d-1-03-01-facp-gp-5ud-data-sheet-9875610234.pdf |
---|---|
Type | |
Size | 681.11 KB |
Downloads |
Text Preview
FACP GP 5UD WITH DACT AND REMOTE SITE U D Fike GatorPro GP 5UD is a 24 volt five zone fire alarm panel with built in communicator and remote site capability The integral communicator transmits information alarms troubles supervisories faults etc to a central station The GP 5UD may be used in a variety of applications including local fire alarm control panel disabled fire alarm control panel communicator sprinkler supervisory communicator or slave to a UL listed host fire alarm panel requires N O dry to trigger five channels Selectable transmission formats allow GP 5UD to communicate to virtually all central stations smoke detectors programmable Initiating Device Circuits zones zone may be programmed for N O contact devices pull heat Waterflow operation operation Supervisory operation built in Class A or B Style Z or Y Notification Appliance Circuits NACs smoke detectors Notification Appliance Circuits may be programmed Program 5 to 30 minutes Inhibit 60 seconds March Time Temporal California Non Silenceable a strobe circuit can keep flashing after the panel is silenced amps of Notification Appliance power expandable to 5.0 amps meets the critical power requirements for ADA UL 1971 devices built in Form C Alarm and Trouble relays and communication fail outputs Dual line rotary or Touch Tone DACT interfaces to public telephone network leased phone lines are not voltage AC line voltage voltage operation voltmeter measures Notification Appliance Circuit s voltage Mount Technology SMT programmable via built in keypad no costly external programmers necessary with NFPA 72 Local Central Station and Remote Station DACT only not polarity reversal Fire Alarm formats include 4 1 4 2 Standard Expanded 4 2 Ademco Express 24 volt power No D 1.03.01 1 S 10th Street P O Box 610 Blue Springs Missouri 64013 0610 U S A 816 229 3405 816 229 4615 www fike com battery charger for up to 60 hours of standby power power limited technology meets UL power limiting requirements Alarm Presignal Timer Alarm Verification Timer and Optional Trouble Reminder walk test drill function disable capability software history buffer with time and date stamp real time clock calendar built in transient protection and operational controls fully enclosed in a lockable cabinet capable of housing up to 7 AH batteries Optional contact by zone module and optional remote annunciator Optional printer interface for on or off line printing SITE UPLOAD DOWNLOAD GP 5UD may be downloaded or uploaded without affecting the system fire protection Download system programming key system information or Download within one minute without affecting normal fire panel functions system status history and walk test files AC line NAC 1 and NAC 2 Resettable Power and Battery Voltages Programming Multiple security techniques PK 5024UD programming kit which works with most Hayes compatible modems consult factory for listing PC board design using Surface Mount Technology SMT modular telephone jacks for connection to RJ31X Modules VAC 50 60 Hz 2.3 amps Power Wire size minimum 14 AWG 2.0 mm with 600 volt insulation brownout circuitry voltmeter signal LED One line active indicator for each of two phone lines Dual low telephone voltage detect circuitry event codes per each format to 62 transmitted events messages transmissions of 62 events zones may be configured to five channels as a slave communicator channels are auto resettable Formats formats allow complete transaction to be communicated in under 5 seconds PPS 3 1 standard and expanded PPS 4 1 standard and expanded PPS 4 2 standard and expanded and 4 2 Ademco Express Device Circuits zones GP 5UD includes five programmable Initiating Device Circuits zones Circuits 1 2 4 and 5 are Style B Class B Circuit is Style D Class A Use the CAC 5F Class A converter module to convert all Class B IDCs to Class A Standard Auto Reset Station zone may support two wire smoke detectors Programming options include Waterflow Silenceable Non Silenceable Normally Open Contact device circuits are power limited and also fully supervised They allow up to 100 ohms of line resistance and allow for use of 12 to AWG 3.1 to 0.78 mm wire Appliance Circuits Style Z Y Class A B 2.5 amps each circuits are fully power limited and meet UL power limiting requirements four wire smoke detector power 300 mA Outputs Non resettable power 300 mA Form C Alarm and Trouble relays drivers for supervisory and communication fail SPECIFICATIONS cabinet is red with a dark blue overlay Knockouts on the top sides and back provide ease of wire entry The cabinet can surface or semi flush mounted and is compact in design Door 15.219 high x 14.219 wide 38.655 cm high x 36.115 cm wide 15.0 high x 14.5 wide x 3.0 deep 38.1 cm high x 36.83 cm wide x 7.62 cm deep Ring P N TR 1 R 18.125 high x 17.62 wide 46.038 cm high x 44.755 cm deep LINE INFORMATION Fike P N 27 002 Five zone 24 volt Fire Alarm Control Communicator includes backbox transformer technical and a frame post operating instruction sheet Fike P N 27 003 120 VAC 100 VA transformer expands NAC power from 3.0 to 5.0 amps Fike P N 27 010 Five zone Remote Annunciator mounts to a single gang box requires ADM 24 Fike P N 27 Fike P N 27 004 Annunciator Driver Module Fike P N 27 005 Five zone Relay Module provides contact by zone Fike P N 27 006 Class A Converter module Converts all Class B Initiating Device Circuits zones to Class A Fike P N 27 008 Printer interface module provides an EIA 232 printer output Includes cable DB9F and DB25 Fike P N 27 009 Contains PK 5024UD and other programming software for Windows PC computer not included Fike P N 27 013 Internal Dress Panel included when ordering Canadian model Fike P N 27 015 DACT phone cord 7 feet long two required Battery backbox Required for batteries over 7 AH Fike P N 27 014 Trim ring RECEIVERS COMPATIBLE WITH THE GP 5UD 16 42 1 Knight CP220FB Models 5 7 9 2 1 Ademco Express 2 Ademco Express 1 Standard 1800 2300 1 Expanded 1800 2300 1 Standard 1900 1400 1 Expanded 1900 1400 1 Standard 1800 2300 1 Expanded 1800 2