Fike P 1 18 01 Photoelectric Smoke Detector

File Preview
File Preview
Click below to download for free

File Data

Name fike-p-1-18-01-photoelectric-smoke-detector-2013987546.pdf
Type PDF
Size 650.32 KB
Downloads

Text Preview

PHOTOELECTRIC SMOKE DETECTOR 63 1024 can be used in all areas where Photoelectric Smoke Detectors required The wide range smoke chamber makes the 63 1024 well suited fires ranging from smoldering to flaming fires 63 1028 is a non listed photoelectric smoke detector The detector is to the 63 1024 except the 63 1028 does not have the magnetic test switch making it suitable for use in areas of high magnetic fields such MRI 4 and 6 smoke detector bases and the 63 1012 two wire auxilliary base may be used with the 63 1024 and 63 1028 Current devices are the 67 1033 ionization detector the 60 1029 and 60 1030 heat detectors Bases 6 Bases 4 Product 430 220 Product 430 220 Product 430 220 Product 430 220 63 1024 63 1028 non listed Listed S4021 Approval 3010873 7272 0410 107 standby current 45uA at 24VDC built in power sensitivity supervision alarm LEDs profile 1.8 high with base or 4 wire base compatibility relay bases available Highly stable operation RF Transient protection Non directional smoke chamber resistant security locking feature magnetic go no go detector test feature smoke labyrinth for cleaning or replacement Sensitivity window verification function meets outlined requirements in NFPA 72 Chapter 7 Inspection and Maintenance with 67 1033 ionization detectors compatible with Hochiki SLK and SIH detectors bases 63 1024 photoelectric smoke detector utilizes two bicolored LEDs for indication of status In a normal standby the LEDs flash Green every 3 seconds When the detector senses that its sensitivity has drifted outside the UL sensitivity window the LEDs will flash Red every 3 seconds When the detector senses smoke and goes into alarm LEDs will latch on Red detector utilizes an infrared LED light source and silicon photo diode receiving element in the smoke chamber In a standby condition the receiving element receives no light from the pulsing LED light source In the event of a smoke enters the detector smoke chamber and light is reflected from the smoke particles to the receiving element light received is converted into an electronic signal S 10th Street P O Box 610 Blue Springs Missouri 64013 0610 U S A 816 229 3405 816 229 4615 www fike com No P 1.18.01 2 cont are processed and compared to a reference level and when two consecutive signals exceeding the reference level received within a specified period of time the time delay circuit triggers the SCR switch to activate the alarm signal LEDs light continuously during the alarm period normal condition both LED flash green Sensitivity Test Feature 63 1024 Photoelectric Smoke Detector has a built in automatic sensitivity test feature When the sensitivity drifts outside of its sensitivity limits both LED flash red When the sensitivity drifts outside of its sensitivity limits and both LED flash red the device needs to be cleaned the alarm state both LED are red continuously returned to the factory for cleaning Refer to Hochiki Technical Bulletin HA 97 for cleaning information spacing smoke detectors following the guidelines listed in NFPA 72 base the number and location of sensors on engineering survey of the area to be detected The Photoelectric smoke detectors cover 900 sq ft contractor shall furnish and install where indicated on the plans Fike 63 1024 photoelectric smoke detectors The detector head and twist lock base shall be UL listed compatible with a UL listed fire alarm panel base shall permit direct interchange with Fike 63 1025 combination photoelectric heat detector 67 1033 ionization smoke detector and or 60 1029 60 1030 fixed temperature rate of rise heat detectors The base shall be appropriate base In the event of partial or complete retrofit the 63 1024 maybe used in conjunction with or as a for Fike detectors 63 1007 63 1016 and the 67 1016 on most HSB and HSC base applications smoke detector shall have two flashing status LEDs for visual supervision When the detector is in standby condition LEDs will flash Green When the detector is outside the UL listed sensitivity window the LEDs will flash Red When detector is actuated the flashing LEDs will latch Red The detector may be reset by actuating the control panel reset sensitivity of the detector shall be capable of being measured It shall be possible to perform a functional test of the without the need of generating smoke The sensitivity of the detector shall be monitored automatically and to verify that it is operating within the Listed sensitivity range facilitate installation the detector shall be non polarized Voltage and RF transient suppression techniques shall be to minimize false alarm potential Auxiliary SPDT relays shall be installed where indicated vandal resistant security locking feature shall be used in those areas as indicated on the drawing The locking feature be field removable when not required Source Voltage Voltage Voltage Current Current Current Velocity Range Temperature Case Material Test Feature Infrared Emitting Diode 30.0 VDC 33.0 VDC VDC 24 VDC max 24 VDC max 24 VDC fpm to 120 0 to 49 PC ABS Blend Sensitivity window verification test Fike Corporation All Rights Reserved No P 1.18.01 2 July 2005 Specifications are subject to change without notice

Related Files