Fike P 1 75 01 400 Series Plug In Smoke Detector

File Preview
File Preview
Click below to download for free

File Data

Name fike-p-1-75-01-400-series-plug-in-smoke-detector-8096243157.pdf
Type PDF
Size 818.48 KB
Downloads

Text Preview

400 SERIES PLUG IN SMOKE DETECTOR Sensor 400 Series plug in smoke detectors are to meet the performance criteria designated by The ion and photo units have a sensing chamber from back pressure air flow dirt and insects This is protected by a fine mesh screen which can be or replaced Additional key features include a recessed option interchangeable ion photo or thermal a variety of mounting bases and a full line of accessories 400 Series ionization smoke detectors include a specially dual source dual unipolar detector chamber design will sense the presence of smoke particles produced by combustion as well as slow smoldering fires This chamber increased stability significantly reduces nuisance alarms provides better performance at higher air velocities 400 Series photoelectronic smoke detectors contain an sensing chamber designed to sense the presence of particles produced by a wide range of combustion A custom integrated circuit incorporates signal to reduce false alarms 400 Series thermal rate of rise with fixed heat detector a unique dual thermistor heat sensing circuit to maximum performance and solid state reliability The 60 1027 is designed to initiate an alarm at 135 and to to a temperature increase in excess of 15 per minute This enables the heat detector to communicate an to the central control panel prior to reaching the static set point for these high rates of rise providing a timely to both rapid and slow temperature increases THis model should be used in applications where rapid is desired and where rapid temperature increases would only be caused by a fire emergency Wide variety of mounting bases with built in shorting spring Detector head plugs easily into base test switch sensitivity metering of detector to meet the requirements of NFPA 72 tamper resistant feature screws for easy wiring Optional recessed mounting Voltage Alarm Current Current MEA Approved MSFM Approved standby current visible LEDs in standby and provide a 360 field viewing angle cover and insect screen for field cleaning Approved Listed Mounting Base Selection Guide 120mA maximum 100mA maximum Ion Photo 63 1015 63 1017 0.5 lb 227 gm 0.3 lb 136 gm cm height cm diameter unflanged base cm diameter flanged base retardant Noryl plastic S 10th Street P O Box 610 Blue Springs Missouri 64013 0610 U S A 816 229 3405 816 229 4615 www fike com No P 1.75.01 Temperature Point Thermal Range Velocity Rating Detector Spacing 63 1015 32 to 120 0 to 49 60 1027 32 to 100 0 to 38 57.2 or 15 rate of rise RH non condensing fpm maximum 3000 fpm maximum ion photo and photo thermal detectors on smooth ceilings as in NFPA 72 spacing of 30 feet 900 sq ft may be used as a For thermal detectors on smooth ceilings as defined in NFPA spacing of 50 feet 2500 sq ft may be used Other spacing may be depending on ceiling height high air movements and other or response requirements BASE SELECTION GUIDE P N Model No Type Current Limit Contact Draw on mA mA AC Max A C A C A C contingent on panel compatibility be limited by control panel base Although 67 1031 and 60 1031 bases are capable of operating at 12 and 24 VDC they cannot be used with the in 12 V applications Contact Ratings or Inductive 60 power factor load A 2.0A at 30 VAC DC B 0.6A at 110VDC 2.0A at 30VDC at 125VAC 2.0A at 30VAC BOX SELECTION GUIDE P N B401 B401R B402B B406B Model No Single Gang 3.5 Octagon 4 Octagon 4 Square 50 mm 60 mm 75 mm Box depth contingent on base and wire size Refer to National Electrical Code of local applicable codes for recommendations SERIES INFORMATION P N P N P N P N detector Must be mounted to one of the B40X bases listed in Mounting Base Guide detector Must be mounted to one of the B40X bases listed in Mounting Base Guide as model 2451 above but with a 135 57.2 fixed temperature bi metallic heat sensor heat detector with rate of rise Alarm point at 57.2 135 Must be mounted one of the 400 Series Bases listed in Mounting Base Guide annunciator for 2 or 4 wire systems 3 32V Use with ion and photo plug in detectors standard U S single gang electrical box base with B401 Requires an external 24 VDC power supply to 4 square electrical box 1 1 2 minimum depth sensitivity test tool See below Use with most analog or digital multimeters Satisfies of NFPA 72 for sensitivity testing See below mounting kit for use with 60 1031 or 60 1033 mounting bases only See below mounting kit provides for entry of surface wiring conduit use with 60 1031 or 60 1033 mounting bases only of line relay for power supervision 12 24 VDC 4 wire only insect screen for 67 1025 insect screen for 63 1015 insect screen for 63 1017 protective dust cover for plug in 400 Series removal tool for 1451 magnet magnet with 32 inch telescoping handle from base in high ceiling installations pole for XR5 Comes in three 5 ft sections removal tool Allows installation and or removal of ion photo and thermal detector Fike Corporation All Rights Reserved No P 1.75.01 September 2005 Specifications are subject to change without notice

Related Files