Fike P 1 77 01 Model BEAM1224 Single Ended Reflected TYpe Smoke Detector
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fike-p-1-77-01-model-beam1224-single-ended-reflected-type-smoke-detector-6024785139.pdf |
---|---|
Type | |
Size | 698.98 KB |
Downloads |
Text Preview
BEAM1224 S SINGLE ENDED REFLECTED TYPE SMOKE DETECTOR Sensor Model BEAM1224 Fike P N 65 1006 is a conventional projected beam smoke detector It is suited for protecting open areas with high ceilings other methods of smoke detection are difficult to and maintain It is to be used with UL Listed compatible panels only Installation of the single ended reflective is much easier than the dual ended projected beam Alignment is quickly accomplished via an optical and a 2 digit signal strength meter incorporated into the Listed for operation from 22 to 131 65 1006 be used in open area applications to provide early warning environments where temperature extremes exceed the of other types of smoke detection Fike P N 65 1006 model consists of a transmitter receiver unit and a When smoke enters the area between the unit and reflector is causes a reduction in the signal and when the level reaches the predetermined threshold an alarm is It has four standard sensitivity selections along with Acclimate settings When either of the two Acclimate are selected the detector will automatically adjust its using advanced software algorithms to select the sensitivity for the specified environment Listed S911 Approved 3017888 7260 1209 228 MEA Approved 54 04 E MSFM Approved 2165 Fike P N 65 1007 model is equipped with an integral sensitivity test feature that consists of a test filter attached to a servo motor the detector optics Using the remote test station P N 02 3869 the motor is activated and moves the filter in the of the light beam thereby testing detector sensitivity This integral sensitivity test feature allows the user to and easily meet the annual maintenance and test requirements of NFPA 72 to 328 foot protection range reflective design friendly alignment procedure user selectable sensitivity levels Optional integral NFPA 72 sensitivity test feature plug in terminal blocks Digital display for easy alignment SPECIFICATIONS Range Angle Levels automatic gain control compensates for signal deterioration from dust build up test station optional cover alignment in the industry ft to 328 ft 5m to 100m degrees horizontal vertical The optics more independent of the unit 1 25 2 30 3 40 4 50 Level 1 30 50 Level 2 40 50 No P 1.77.01 S 10th Street P O Box 610 Blue Springs Missouri 64013 0610 U S A 816 229 3405 816 229 4615 www fike com Condition Trouble Aid Indicator Indicator Indicator Features Detector Spacing or more obscuration blockage In alignment mode Improper initial Self compensation limit reached gunsight Integral signal strength indication 2 digit display red LED and remote alarm yellow LED and remote trouble flashing green LED SensitivityTest Filter 65 1007 only Sensitivity filter Incremental on reflector Local alarm test switch Local alarm reset switch test and reset switch Compatible with 02 3869 and 02 4998 test smooth ceilings 30 60 feet between projected beams and not more one half that spacing between a projected beam and a sidewall spacing may be used depending on ceiling height airflow and response requirements See NFPA 72 SPECIFICATIONS Standby Current 24VDC Alarm Current 24VDC Alignment Mode Current 24VDC SPECIFICATIONS Dimensions Dimensions 16 to 230 Dimensions for beyond 20 to 32 VDC 65 1006 to 32 VDC 65 1007 65 1007 should not be used with 12V power sources Max Max Max x 7.5 x 3.3 254mmH x 191mmW x 84mmD x 9.1 200 x 230mm x 18.1 400 x 460mm SPECIFICATIONS 02 11500 Consumption Per Reflector to 32V Max at 32V per reflector 24V 15W 32V SPECIFICATIONS 02 11499 Consumption to 32V at 32V 24V 3W 32V INFORMATION P N P N conventional beam smoke detector with 8 reflector conventional beam smoke detector with8 reflector integral sensitivity test range accessory kit 3 additional reflectors Required for in excess of 230 ft 70m kit Provides ceiling or wall mount capability with increased adjustment for either the beam or the reflector When installed the transmitter receiver unit 02 11498 must be used as well mount kit test station used to initiate the NFPA sensitivity test function test station with key lock kit for transmitter receiver unit See electrical requirements kit for reflector See electrical requirements Fike Corporation All Rights Reserved No P 1.77.01 September 2005 Specifications are subject to change without notice