Fike P 1 79 01 4 Wire Duct Smoke Detector
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fike-p-1-79-01-4-wire-duct-smoke-detector-2315760498.pdf |
---|---|
Type | |
Size | 1.16 MB |
Downloads |
Text Preview
4 WIRE DUCT SMOKE DETECTOR System Sensor Innovair Fike P N 67 1048 is a 4 wire air duct smoke detector capable of sensing smoke air velocities from 500 to 4,000 feet per minute 2.54 to m sec This detector was developed to constantly the air within a duct and to detect the presence of two available for C relay contacts provide reliable for the management of fans blowers and air systems These HVAC devices can be configured prevent the spread of toxic smoke and fire gasses through protected area Innovair family is designed for simplified installation and maintenance The modular construction allows for easy and uncomplicated field replacement of the UL power and sensor boards The patented cover feature insures the cover is securely tightened routine cleaning and maintenance The patented feature allows multiple Innovairs to with each other In the event smoke is detected Innovair will signal the remaining interconnected detectors initiate their relays for smoke control Duct smoke detectors have specific limitations Listed Approved Smoke Detectors are NOT a substitute for an open area smoke detector NOT a substitute for early warning detection and NOT a replacement for a building regular fire detection system to NFPA 72 and 90A for additional information about the proper application of duct smoke detectors High Low voltage barrier Outside mounting tabs velocity rating from 500 to 4000 feet per minute 2.54 to 20.32 m sec Interconnectability for multi fan shutdown up to ten air handlers telescopic sampling tube cover tamper trouble signal VAC DC or 120 240 VAC operation with two DPDT Form C relay contacts reset button and quick mounting to round or rectangular ducts from 1 0.3 3.7 meters wide to clean recognized field replaceable power and sensor boards test station option sounder option cover for convenient visual inspection 268A listed warranty model available S 10th Street P O Box 610 Blue Springs Missouri 64013 0610 U S A 816 229 3405 816 229 4615 www fike com No P 1.79.01 SPECIFICATIONS air duct smoke detector shall be a System Sensor Model Fike P N 67 1048 Series Duct Smoke Detector The housing shall be UL listed per UL 268A specifically for use in the air handling systems The detector shall at air velocities of 500 feet per minute to 4000 feet per minute 2.54 to 20.32 meters second The unite shall be of controlling up to ten 10 air handling systems when interconnected with other detectors The detector shall capable of providing a trouble signal in the even that the front cover is removed It shall be capable of local testing magnetic switch or remote testing using 02 11489 Multi Signaling Accessory or 02 4998 Remote Test Station The shall be reset by local reset button or remote test station The duct smoke detector housing shall incorporate an smoke chamber in compliance with UL 268A Standard for Smoke Detectors for Duct Applications The housing be capable of mounting to either rectangular or round ducts without adapter brackets An internal filter system shall included to reduce dust and residue effects on detector and housing thereby reducing maintenance and servicing tubes shall either be telescoping or be easily installed by passing through the duct housing after the housing is to the duct The unit shall provide a spacial separation of no less than 1 4 6.4 mm and or a physical barrier the high and low voltage terminals The enclosure shall meet all applicable NEC and NFPA standards regarding junction boxes Terminal connections shall be of the strip and clamp method suitable for 12 18 AWG wiring GUIDE Weight Temperature Range Humidity Range Duct Velocity 37 cm Length 5 1 2 14 cm Width 2 3 4 7 cm Depth lbs 1.7 kg to 120 0 to 49 to 93 relative humidity non condensing to 4000 ft min 2.54 to 20.32 m sec RATINGS P N 67 1048 INCLUDES DETECTOR Supply Voltage Capacitance Voltage Time with RTS451 Time by power down Up Time Response Time VDC max VDC min to 0.3 sec sec max sec max to 17 sec VAC 50 60 Hz VAC 50 60 Hz VAC 50 60 Hz max VAC min to 0.3 sec sec max sec max to 17 sec VAC min to 0.3 sec sec max sec max to 17 sec VAC min to 0.3 sec sec max sec max to 17 sec Test detector label detector label detector label detector label Standby Current Alarm Current Initiation Contacts SPST Auxiliary contacts DPDT Requirements Using No Accessories mA mA mA RMS mA RMS Ratings mA RMS mA RMS mA RMS mA RMS 30 VAC DC 0.6 power factor 30 VDC 250 VAC Alarm auxiliary contacts must switch 100 mA minimum at 5VDC Alarm auxiliary shall not be connected to initiating circuits of control panels Use the alarm initiation for this purpose Contacts SPDT 30 VDC resistive Current Loads at 24 VDC Max Max Max Max Max P N Max max 30mA Max diagram for 67 1048 to 02 11490 When a unit is powered at the 120VAC or 220 240VAC input combination of accessories may be used such that the given loads are 50 mA or less in the standby state 110 mA or less the alarm state Interconnect Notes using the interconnect feature all interconnected units be powered with the same independent supply must be maintained throughout the interconnect wiring terminal 12 on unit 1 to terminal 12 on unit 2 and so Similarly connect terminal 1 on unit 1 to terminal 1 on unit and so on diagram for the 02 3869 02 4998 and feature Diagram for 67 1048 to 02 11489 interconnect feature Note Please note that the magnetic coil supplied with the 02 3869 02 4998 is required when these accessories are used with the 63 1050 detector The of the magnetic coil has been designed into the circuitry of the Innovair smoke detectors INFORMATION P N P N ionization duct detector ionization detector board 4 wire power board sampling tube duct widths 1 0.3 0.6 m sampling tube duct widths 2 0.6 1.2 m sampling tube duct widths 4 1.2 2.4 m sampling tube duct widths 8 2.4 3.7 m telescoping sampling tube end cap for T80 71 00 accessory test station with key lock test station annunciator with piezo alarm test module annunciator alarm LED air filters two per package magnet cap for metal sampling tubes replacement screen sounder add on strobe lens Sensor provides system flexibility with a variety of accessories including two remote test stations and several different of visible and audible system annunciation As with our duct detectors all duct smoke detector accessories are UL listed 02 11490 Annunciator S4011 02 4998 Test Station Key UL S2522 02 3869 Test Station S2522 02 3868 Annunciator S2522 20 130 134 Sounder S3593 02 11489 Accessory 268A 02 11489 Accessory 268 shown with 20 1091 add on strobe 02 11491 smoke lens availa