Fike System Sensor 400 Series Direct-Wire Ionization Smokes A05-0219

File Preview
File Preview
Click below to download for free

Text Preview

400 Series Ionization Detector 2 Wire Ionization Smoke Detector Available 2 Wire 4 Wire 4 Wire End of line relay module VDC LED annunciator Sensitivity test module cover removal tool screen Overview or 24 volt operation cover and insect screen for cleaning LED blinks in standby latches on alarm mounting bracket with option unipolar chamber design screws for easy wiring warranty against dirt insects and pressure 400 Series ionization smoke detectors include a unique dual source dual unipolar detection design which will sense the presence of smoke particles produced by combustion as well as slow smoldering This chamber exhibits increased stabili signi reduces nuisance alarms and provides better performance at higher air 400 Series meets the performance criteria required by UL ULC Additional key fea include an LED which blinks in standby and latches on to indicate an alarm feature convenient testing and sensitivity metering The model 1400 remote LED annunciator capabilities using the RA400Z detector shall be an ionization type model 1400 1412B or 1424 as manufac by System Sensor Wiring connections shall be made by means of SEMS screws will have a visible LED which will blink in standby and latch on in alarm The shall have a sensitivity of 1.9 0.6 ft as measured in the UL smoke box The screen and cover should be easily removable for cleaning It shall be possible to a sensitivity and functional test on the detector without the need of generating The detector shall have a mounting bracket that allows for mounting to a 3 1 2 4 octagon box or 4 square electrical box sensitivity metering of detector to NFPA 72 requirements Speci 8.1 cm 13.9 cm Weight lbs Ratings Operating Voltage Current Contact Ratings Humidity Range to 93 Relative non condensing Velocity Rating fpm maximum 0.6 ft nominal or 4 octagon box square box with plaster ring 60 75 mm boxes per NFPA 72 and local require On smooth flat ceilings spac of 30 feet may be used as a guide Temperature Range to 120 0 to 49 AWG twisted pair recommended VDC 8.5 35 VDC max control panels be current limited mA or less VDC 11.3 17.3 VDC max mA VDC 20 29 VDC max mA Form A Alarm Form C Auxiliary Alarm 30 VAC DC 30 VAC DC 6A 110 VDC 1A 125 VAC Informaton Number detector 2 wire 12 24 VDC for control panels detector 4 wire 12 VDC for control panels detector 4 wire 24 VDC for control panels of line relay module 12 24 VDC annunciator LED Test module see below cover removal tool screen MOD400R Field Sensitivity Test Module be used with any standard DC voltmeter multimeter to check the sensitivity range System Sensor detectors satisfies 72 requirement for sensitivity testing Sensor Sales and Service Sensor Headquarters Ohio Avenue Charles IL 60174 800 SENSOR2 630 377 6495 on Demand x3 Sensor Canada 905.812.0767 905.812.0771 Sensor Europe 44.1403.276500 44.1403.276501 Sensor in China 86.29.524.6253 86.29.524.6259 Sensor in Singapore 65.273.2230 65.273.2610 Sensor in Far East 85.22.191.9003 85.22.736.6580 Sensor in Australia 613.54.281.142 613.54.281.172 Sensor in India 91.11.558.2119 91.11.527.6815 2001 System Sensor The company reserves the right to change product speci without notice

Related Files