Fike System Sensor Low Flow Duct Detector

File Preview
File Preview
Click below to download for free

File Data

Name fike-system-sensor-low-flow-duct-detector-9430528167.pdf
Type PDF
Size 218.07 KB
Downloads

Text Preview

H V A C S Y S T E M S M O N I T O R I N G Low Flow Smoke Detector 4 Wire Photoelectric Smoke Detector Low Flow Overview velocity rating from to 4000 feet per minute to 20.32 m sec interconnectabillity for multi shutdown up to ten air handlers telescopic sampling tube cover tamper trouble signal VAC DC or 120 240 VAC operation voltage barrier with two DPDT Form C relay reset button mounting tabs and quick mounting to round rectangular ducts from 1 meters wide to clean recognized and sensor boards test station option sounder option cover for convenient inspection 268A listed warranty System Sensor Innovair DH100ACDCLP is a 4 wire photoelectric air smoke detector capable of sensing smoke in air velocities from 100 to feet per minute 0.5 to 20.32 m sec This Innovair features Low Flow that enables duct smoke detection throughout a broad range of air environments Many dif to solve HVAC applications occur in low air duct applications where reliable smoke detection is critical Innovair with technology can detect smoke at air speed velocities of 100 feet per or greater while continuing the same reliable performance to 4,000 feet minute two available form C relay contacts provide reliable performance for the of fans blowers and air conditioning systems These HVAC can be con to prevent the spread of toxic smoke and gasses a protected area Innovair family is designed for simpli installation and easy mainte The modular construction allows for easy cleaning and uncomplicated replacement of the UL recognized power and sensor boards The patented missing feature insures the cover is securely tightened following routine and maintenance The patented interconnectability feature allows mul Innovairs to communicate with each other In the event smoke is detected Innovair will signal the remaining interconnected detectors to initiate their for smoke control Duct smoke detectors have speci limitations SMOKE DETECTORS ARE a substitute for an open area smoke detector a substitute for early warning detection and a replacement for a building regular system to NFPA 72 and 90A for additional information about the proper of duct smoke detectors Speci air duct smoke detector shall be a System Sensor Model DH100ACDCLP Series Duct Smoke Detector The detector shall be UL listed per UL 268A specifically for use in air handling systems The detector shall operate at air veloci of 100 feet per minute to 4000 feet per minute 0.5 to 20.32 m sec The unit shall be capable of controlling up to 10 air handling systems when interconnected with other detectors The detector shall be capable of providing a trou signal in the event that the front cover is removed It shall be capable of local testing via magnetic switch or remote using the SSK451 Multi Signaling Accessory or the RTS451KEY Remote Test Station The unit shall be reset by reset button or remote test station The duct smoke detector housing shall incorporate an airtight smoke chamber in with UL 268A Standard for Smoke Detectors for Duct Applications The housing shall be capable of mounting either rectangular or round ducts without adapter brackets An integral filter system shall be included to reduce dust residue effects on detector and housing thereby reducing maintenance and servicing Sampling tubes shall either be or be easily installed by passing through the duct housing after the housing is mounted to the duct The unit provide a spacial separation of no less than 1 6.4 mm and or a physical barrier between the high and low voltage The enclosure shall meet all applicable NEC and NFPA standards regarding electrical junction boxes Terminal shall be of the strip and clamp method suitable for 12 AWG wiring Guide wiring diagram for 4 wire duct smoke detectors INPUTS ACCEPT VDC 24 VAC 50 60 HZ VAC 50 60 HZ OR VAC 50 60 HZ POWER SOURCE APPROPRIATE TERMINALS EACH DETECTOR CONTACT RATINGS 30 VDC RESISTIVE 250 VAC MINIMUM 5 VDC INTENDED FOR TO CONTROL POWER INPUTS POWER INPUTS AUXILIARY CONTACTS FAN SHUTDOWN ETC AUXILIARY CONTACTS FAN SHUTDOWN ETC AUXILIARY CONTACTS SHOWN IN CONTACTS TRANSFER DURING AS INDICATED BY THE ARROWS AUXILIARY CONTACTS SHOWN IN CONTACTS TRANSFER DURING AS INDICATED BY THE ARROWS CONTACT RATING A 30 VDC resistive TROUBLE CONTACTS TROUBLE CONTACTS POWER SOURCE APPROPRIATE TERMINALS EACH DETECTOR SEE FOR POWER SUPPLY WIRING OF AUXILIARY REFER TO INSTRUCTIONS CONTACT MANUFACTURER THE SUPERVISORY RELAY NOW A FORM C CONTACT FOR APPLICATIONS STANDARD APPLICATIONS ONLY NO CONTACT IS USED CONTACTS CLOSED IN ALARM AND STANDBY OPEN WHILE DETECTOR PCB OR POWER IS OR WHEN TAMPER FEATURE TIMES OUT OPEN SIGNAL TROUBLE CONDITION TO PANEL CONTACTS CLOSED IN ALARM AND STANDBY OPEN WHILE DETECTOR PCB OR POWER IS OR WHEN TAMPER FEATURE TIMES OUT OPEN SIGNAL TROUBLE CONDITION TO PANEL SHOWN IN STANDBY CLOSE ALARM SHOWN IN STANDBY CLOSE ALARM LISTED 4 WIRE PANEL DETECTOR IN THE LOOP DETECTOR IN THE LOOP RESISTOR BY MANUFACTURER 37 cm Length 14 cm Width 7 cm Depth Weight lbs 1.7 kg Temperature Range to 131 0 to 55 Temperature Range to 158 to 70 Humidity Range to 93 relative humidity non condensing Duct Velocity to 4000 ft min 0.5 to 20.32 m sec Ratings DH100ACDCLP Includes Detector supply voltage capacitance voltage time with RTS451 time by power down up time response time Test VDC max VDC min to 0.3 sec sec max sec max to 17 sec VAC 50 60 Hz VAC 50 60 Hz VAC 50 60 Hz max VAC min to 0.3 sec sec max sec max to 17 sec VAC min to 0.3 sec sec max sec max to 17 sec VAC min to 0.3 sec sec max sec max to 17 sec detector label detector label detector label detector label Supply Voltage 29 VDC VAC 50 60 Hz VAC 50 60 Hz VAC 50 60 Hz REQUIREMENTS USING NO ACCESSORIES standby current alarm current RATINGS mA mA mA RMS mA RMS mA RMS mA RMS mA RMS mA RMS initiation contacts SPST 30 VAC DC 0.6 power factor auxiliary contacts DPDT 30 VDC 250 VAC Alarm auxiliary contacts must switch 100mA minimum at 5VDC Alarm auxiliary contacts shall not be to inititaing circuits of control panels Use the alarm initiation contact for this purpose contacts SPDT 30 VDC resistive diagram for DH100ACDCLP to APA451 CURRENT LOADS AT 24 VDC Max Max Max Max Max Max Max Max When a unit is powered at the 120VAC or 220 240VAC input any combination of accessories may be used such that the given accessory loads are mA or less in the standby state 110 mA or less in the alarm state Signal Power N O COM Power Wiring diagram shown is for DH100ACDCLP 4 wire duct detector system equipped without a control panel A troub

Related Files