Fike Weatherproof Strobe P 1 35 01
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fike-weatherproof-strobe-p-1-35-01-5746892301.pdf |
---|---|
Type | |
Size | 761.92 KB |
Downloads |
Text Preview
Architect and Engineer Specification 20 125 RSSWP 2475W Strobe Listed Approval Pending Listing Pending MEA Pending BFP Pending Weatherproof Strobe Audible Strobe and Audible all have an extended temperature range of 31 F 150 35 to 66 and will satisfy virtually all outdoor and environment applications All strobes are Indoor Outdoor 1638 Listed and rated for 75 candela 35 Wheelock Weatherproof Appliances are designed for maxi performance reliability and cost effectiveness while meet or exceeding the latest requirements of NFPA 72 National Alarm Code UL Standard 1638 Standard for Visual Sig Appliances and UL 464 Standard for Audible Signaling RSSWP Strobes Series ASWP Audible Strobes and AHWP Audibles may be synchronized when used in con with the Wheelock SM and DSM Sync Modules or the Power Supply with Wheelock Patented Sync Pro Strobes Series RSSWP UL 1638 approved for Indoor Outdoor use the strobes use Xenon flashtube with solid state circuitry enclosed in a rugged lens to provide maximum visibility and reliability for ef visual signaling Approvals include UL 1638 UL 464 New York City MEA California State Fire CSFM Factory Mutual FM and Chicago BFP Meets OSHA 29 Part 1910.165 UL 1638 Listed with an extended temperature range of 31 to 150 35 to 66 VDC with wide new UL Voltage Range of VDC using filtered DC or unfiltered FWR voltage Synchronize with Wheelock Series SM DSM Sync or PA 12 24 8 Power Supply with built in sync All CAUTIONS and WARNINGS are identified by the All warnings are printed in bold capital letters WARNING PLEASE READ THESE SPECIFICATIONS ASSOCIATED INSTALLATION INSTRUCTIONS CARE BEFORE USING SPECIFYING OR THIS PRODUCT FAILURE TO COMPLY WITH OF THESE INSTRUCTIONS CAUTIONS OR WARN COULD RESULT IN IMPROPER APPLICATION AND OR OPERATION OF THESE PROD IN AN EMERGENCY SITUATION WHICH COULD IN PROPERTY DAMAGE AND SERIOUS INJURY DEATH TO YOU AND OR OTHERS Notes are designed to flash at 1 flash per second over the Regulated Voltage Range Note that 1999 specifies a flash rate of 1 to 2 flashes per and ADA Guidelines specify a flash rate of 1 to 3 per second candela ratings represent minimum effective Strobe based on UL 1971 AS Strobe products are listed under UL 1971 for use with a temperature range of 32 F to 120 F C to 49 C and maximum humidity of 85 AH 24 horns are listed under UL 464 for audible appliances Indoor use only AH 24WP audible appliances are listed under 464 for indoor outdoor use with a temperature range of to 150 35 to 66 and maximum humidity of Voltage Range is the newest terminology by UL to identify the voltage range Prior to this UL used the terminology Voltage S 10th Street P O Box 610 cid 127 Blue Springs Missouri 64013 0610 U S A cid 127 816 229 3405 cid 127 Fax 816 229 0314 cid 127 2002 Issue www fike com and Engineers Specifications Weatherproof Strobe appliances shall be Series RSSWP 2475W strobes or approved equals Series RSSWP shall meet and be listed for UL Standard Standard for Visual Signaling Appliances for Indoor use The strobe appliances shall produce a flash rate 30 62 flashes per minute over the Regulated Voltage Range 16 to 33 VDC and shall incorporate a Xenon flashtube in a rugged Lexan lens The strobe shall be rated at and shall operate over an extended temperature range of to 150 35 to 66 All inputs shall be polarized for with standard reverse polarity supervision of wiring by a Fire Alarm Control Panel When synchroniza is required the appliances shall be compatible with the Series SM and DSM Sync Modules or the Wheelock Power Supply with built in patented sync protocol strobes shall not drift out of synchronization at any time operation If the sync module fails to operate i e remain closed the strobe shall revert to a non flash rate Weatherproof Audible Strobe and Audible shall be Wheelock Series ASWP 2475W Audible and Wheelock Series AHWP Audible Horns or equals The Series ASWP and Series AHWP shall and be listed for UL Standard 1638 Standard for Visual Appliances for Indoor Outdoor use The strobe shall produce a flash rate of 30 62 flashes per over the Regulated Voltage Range of 16 to 33 VDC and incorporate a Xenon flashtube enclosed in a rugged lens The strobe shall be rated at 75cd and shall over an extended temperature range of 31 to 150 to 66 All inputs shall be polarized for compatibility standard reverse polarity supervision of circuit wiring by a Alarm Control Panel FACP weatherproof audible strobe appliances shall be for two wire operation and shall provide either a or temporal Code 3 tone when constant voltage a Notification Appliance Circuit NAC of the Fire Alarm Panel FACP is applied They shall be designed so the audible signal may be silenced while maintaining activation When synchronization is required the shall be compatible with the WheelockSeries SM DSM Sync Modules or the Wheelock PS 12 24 8 Power with built in patented sync protocol The strobes shall drift out of synchronization at any time during operation If sync fails to operate i e contacts remain closed the shall revert to a non synchronized flash rate CONTACT WHEELOCK FOR THE CURRENT INSTRUCTIONS AND INFOR SHEET P82380 ON THESE PRODUCTS THESE UNDERGO PERIODIC CHANGES IT IS THAT YOU HAVE CURRENT INFORMATION ON PRODUCTS THESE MATERIALS CONTAIN IMPOR INFORMATION THAT SHOULD BE READ PRIOR TO OR INSTALLING THESE PRODUCTS INCLUD TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER FUSE RATINGS ON NOTIFICATION APPLIANCE CIR TO HANDLE PEAK CURRENTS FROM ALL ON THOSE CIRCUITS ADDING REPLACING OR CHANGING APPLIANCES WILL CURRENT DRAW RECALCULATE CURRENT TO INSURE THAT THE TOTAL AVERAGE CUR AND TOTAL PEAK REQUIRED BY ALL APPLI DO NOT EXCEED THE RATED CAPACITY OF THE SOURCE OR FUSES COMPOSITE FLASH RATE FROM MULTIPLE STROBES A PERSON FIELD OF VIEW THE VOLTAGE APPLIED TO THESE PRODUCTS MUST WITHIN THEIR VOLTAGE RANGE USE STROBES ONLY ON CIRCUITS WITH CONTINU APPLIED OPERATING VOLTAGE DO NOT USE ON CODED OR INTERRUPTED CIRCUITS IN THE APPLIED VOLTAGE IS CYCLED ON AND OFF THE STROBE MAY NOT FLASH FAILURE TO COMPLY WITH THE INSTALLATION IN OR GENERAL INFORMATION SHEETS RESULT IN IMPROPER INSTALLATION APPLICA AND OR OPERATION OF THESE PRODUCTS IN AN SITUATION WHICH COULD RESULT IN DAMAGE AND SERIOUS INJURY OR DEATH YOU AND OR OTHERS CONDUCTOR SIZE AWG LENGTH AND AMPACITY BE TAKEN INTO CONSIDERATION PRIOR TO AND INSTALLATION OF THESE PRODUCTS IN RETROFIT INSTALLATIONS Fike Corporation All rights reserved No previously 1209 are subject change without notice