Fire-Lite CMF-300 Control Module Installation Instructions

File Preview
File Preview
Click below to download for free

Text Preview

I Control Module Instructions to 32VDC LED flashing in group poll mode 350 LED of flashing in direct poll mode Max Communicating NAC Shorted VDC Operating Voltage Operating Current NAC Line Loss Supply Voltage between Terminals T3 and T4 NAC Speakers NAC Current Ratings Range 24VDC V RMS 50 W class B wiring system the current rating is 3A class A wiring system the current rating is 2A to 120 0 to 49 to 93 Non condensing H 4 W 11 4 D Mounts to a 4 square by 21 8 deep box Electrical Box CB500 Barrier Installing information is included as a quick reference installation guide Refer to the control panel installation manual for system information If the modules will be installed in an existing operational system inform the operator and authority that the system will be temporarily out of service Disconnect power to the control panel before installing modules This manual should be left with the owner user of this equipment Description Supervised Control Modules are intended for use in addressable two wire systems where the individual address each module is selected using the built in rotary switches This module is used to switch an external power supply can be a DC power supply to notification appliances It also supervises the wiring to the connected loads and re their status to the panel as NORMAL OPEN or SHORT CIRCUIT The CMF 300 has two pairs of output termination available for fault tolerant wiring and a panel controlled LED indicator This module can be used to replace a C304 that has been configured for supervised wiring operation Requirements ensure proper operation these modules shall be connected to listed compatible system control panels only CMF 300 mounts directly to 4 square electrical boxes see Figure 2A The box must have a minimum depth of 21 8 mounted electrical boxes SMB500 are available relay switch contacts are shipped in the standby state open state but may have transferred to the activated closed during shipping To ensure that the switch contacts are in their correct state modules must be made to communicate the panel before connecting circuits controlled by the module Fire Alarms Inc Alarms Inc One Fire Lite Place Northford CT 06472 203 484 7161 All wiring must conform to applicable local codes ordinances and regulations When using control modules in non limited applications the CB500 Module Barrier must be used to meet UL requirements for the separation of power and nonpower limited terminals and wiring The barrier must be inserted into a 4 junction box and the module must be placed into the barrier and attached to the junction box Figure 2A The power limited wiring must placed into the isolated quadrant of the module barrier Figure 2B Install module wiring in accordance with the job drawings and appropriate wiring diagrams Set the address on the module per job drawings Some panels support extended addressing In order to set the module above address 99 on compatible systems remove the stop on the upper rotary switch with thumb in the direction shown in Figure 1 Secure module to electrical box supplied by installer as shown in Figure 2A 1A Controls and indicators 2A Module mounting with barrier 2B 865 6 7 8 9 3 Typical Notification Appliance Circuit configuration NFPA Style Y Class B MODULES TO LISTED COMPATIBLE LITE CONTROL PANELS ONLY NEXT LINE CIRCUIT SLC VDC MAX PAIR RECOMMENDED WIRING SHOWN IS SUPERVISED AND POWER LIMITED PANEL OR DEVICE 865 6 7 8 9 VDC CIRCUIT NOT LOOP WIRE ON TERMINALS 4 BREAK WIRE RUN TO PROVIDE OF CONNECTIONS VDC POWER SUPPLY REGULATED POWER PER NFPA 70 FOR FIRE PROTECTION WITH BACKUP POLARITIES ARE IN ALARM EOL LISTED EOL RELAY ENERGIZED VDC COIL TERMINALS 3 4 THE LAST CONTROL ON CIRCUIT NEXT CONTROL MODULE END OF LINE RELAY EOLR EOLR REQUIRED PER VDC CIRCUIT 4 Typical fault tolerant Notification Appliance Circuit configuration NFPA Style Z Class A WIRING SHOWN IS SUPERVISED POWER LIMITED LINE CIRCUIT SLC VDC MAX PAIR RECOMMENDED NEXT MODULES TO LISTED COMPATIBLE LITE CONTROL PANELS ONLY PANEL OR DEVICE 865 6 7 8 9 POLARITIES ARE IN ALARM TERMINALS 3 4 THE LAST CONTROL ON CIRCUIT NEXT CONTROL OR END OF RELAY EOLR ONE REQUIRED PER VDC CIRCUIT RESISTOR IS AT 8 9 LISTED EOL RELAY ENERGIZED COIL VDC CIRCUIT NOT LOOP WIRE ON TERMINALS 4 BREAK WIRE RUN TO PROVIDE OF CONNECTIONS VDC POWER SUPPLY REGULATED POWER PER NFPA 70 FOR FIRE PROTECTION WITH BACKUP

Related Files