Fire-Lite MS-9600LS(E) MS-9600UDLS(E)

File Preview
File Preview
Click below to download for free

File Data

Name fire-lite-ms-9600ls-e-ms-9600udls-e-9854216073.pdf
Type PDF
Size 951.79 KB
Downloads

Text Preview

MS 9600LS E MS 9600UDLS E Addressable FACP Optional Second Loop A1 100 Control Panels MS 9600LS E and MS 9600UDLS E are compact cost intelligent addressable FACPs Fire Alarm Control Panels an extensive list of powerful features The combination of newer series devices and legacy 300 Series devices with the MS 9600LS E or MS 9600UDLS E FACP offer the in fire protection technology LiteSpeed is a patented tech that polls 10 devices at a time looking for new or different When new information is found at a specific address system polls that device several times for any new data This allows a fully loaded panel with up to 636 devices to an incident and activate the notification circuits in under 10 With this polling scheme devices can be wired on stan twisted unshielded wire up to a distance of 10,000 feet per Each Signaling Line Circuit SLC loop supports up to 159 detectors including photoelectric photoelectric with beam ionization photoelectric duct fixed heat fixed heat with and fixed high heat detectors It also supports up to 159 modules including monitor two wire detector normally devices dual monitor functions two monitor circuits from one two addresses used multi monitor multiple monitor cir from one module multiple addresses used control for Notifi Appliance Circuits and relay two Form C modules FLPS 7 power supply is a separate board while all other elec are contained on a single main circuit board Both boards are to a quick removable chassis and housed in a metal cabi The backbox can be installed allowing field wiring to be pulled construction is completed the chassis with the electronics be quickly installed with two bolts MS 9600UDLS E includes a factory installed 2 Digital Alarm Transmitter The DACT transmits system status troubles AC loss etc to a Central Station via internet IPDACT installed or the public switched telephone net modules which plug into the main circuit board are avail for special functions Available accessories include LED and LCD annunciators reverse polarity city box transmitter alarm communicator transmitter SLC expansion module and remote upload download software and remote power APPROVED to UL ANSI 864 Unless otherwise specified the term MS 9600LS is used in this to refer to the MS 9600LS MS 9600UDLS MS 9600LSE and FACPs Fire Alarm Control Panels And Indicators INDICATORS AC POWER green FIRE ALARM red SUPERVISORY yellow ALARM SILENCED yellow SYSTEM TROUBLE yellow MAINTENANCE PRESIGNAL yellow DISABLED yellow BATTERY FAULT yellow GROUND FAULT yellow SWITCH CONTROLS ACKNOWLEDGE STEP ALARM SILENCE DRILL SYSTEM RESET lamp test 12 key pad with full alphabet 4 cursor keys ENTER Features Easy mount chassis 7 amp switching power supply Large enclosure allows 18 amp hour batteries 2 plug in communicator standard with MS 9600UDLS E Optional IPDACT Internet Protocol Digital Alarm Communicator Four Style Y Class B or two Style Z Class A circuits Selectable strobe synchronization per NAC for Sensor Wheelock and Gentex devices Certified for seismic applications when used with the appropriate mounting kit Seamless integration between fire and mass notification with the Emergency Command Center via ANN BUS con ECC FFT Firefighter Telephone Option ANN BUS for connection to following optional modules cannot be used if ACS annunciators are used ANN 80 W Remote LCD Annunciator ANN I O LED Driver Module ANN S PG Serial Parallel Printer Module 2 20 2019 Page 1 of 6 ANN RLY Relay Module ANN LED Annunciator Module ANN RLED Annunciator Module alarms only Compatible with SWIFT wireless devices Features LOOP SLC can be configured for NFPA Style 4 6 or 7 operation SLC supports up to 318 addressable devices per loop 159 and 159 monitor control or relay modules SLC loop maximum length 10,000 ft 3,048 m 12 AWG 3.1 using twisted unshielded wire see Wire Table on page 5 APPLIANCE CIRCUITS NACS Four onboard NACs with additional NAC capability using output modules CMF 300 or CMF 300 6 The four Class B can be converted to two Class A NACs with the NACKEY Silence Inhibit and Auto Silence timer options Continuous March Time Temporal or California code for main board NACs with two stage capability Selectable strobe synchronization per NAC 3.0 amps special application 300mA regulated maximum per NAC circuit Maximum 24 VDC system power output is shared among NAC circuits and 24 VDC special application auxiliary power Total available output is 7.0 amps FIRE TECHNOLOGY Sensitivity testing with printable results on site or off site Automatic drift compensation AND SOFTWARE Autoprogramming learn mode reduces installation time Fully programmable from local keypad local PS 2 keyboard or using the standard PS Tools Windows utility Two level user programmable passwords Custom English labels per point may be manually entered or from an internal library file Three Form C relay outputs two programmable 99 software zones INTERFACE Optional plug in 2 communicator with MS with USB port for local upload download Remote Acknowledge Silence Reset and Drill via addressable modules ACS Series annunciators LCD 80F remote or ANN 80 Series Annunciators EIA 232 printer PC interface variable baud rate on main circuit 80 character LCD display with backlighting Real time clock calendar with automatic daylight savings adjust History file with 1,000 event capacity EIA 485 ANN BUS supporting up to 8 ANN Series Annunciators 32 ACS Series annunciators EIA 485 supporting up to 32 ACS annunciators Maintenance alert warns when smoke detector dust accumula is excessive Automatic device type code verification One person audible or silent walk test with walk test log and print Point trouble identification 2 of 6 DF 60334 A6 2 20 2019 Local piezo sounder Waterflow non silenceable selection per monitor point System alarm verification selection per detector point PAS Positive Alarm Sequence and presignal delay per point Optional 4XTMF module conventional reverse polarity city box 72 compliant Features Programming Create the entire program in your office a Windows software package download PS Tools www firelite com Upload download system programming to the MS 9600LS in less than one minute Command the MS 9600LS to program itself less than 30 seconds In the Auto Program mode the MS scans for all possible devices at all addresses stores the types and addresses found and then loads default values all options General Alarm It also checks for two or more set to the same address Editing While still providing fire protection the MS 9600LS may be programmed from the front panel Simple menu trees dis on the LCD allow the trained user to perform all functions referring back to the programming manual Label Library Quickly select labels from a standard library more than 50 adjectives nouns such as 3 HALLWAY or custom labels letter by letter Use recall function to repeat pre used label Check Automatically catch common errors such as con modules not linked to any zone or input point Alert MS 9600LS E continuously monitors each smoke detector and capable of reporting maintenance conditions This reduces the of false alarms due to dust accumulation Refer to the control installation manual

Related Files