Fire-Lite VisorAlarm Plus IP
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fire-lite-visoralarm-plus-ip-8796503124.pdf |
---|---|
Type | |
Size | 794.45 KB |
Downloads |
Text Preview
g PLUS Alarm Receiver MIP and IPDACT modules VisorALARM PLUS receiver is Teldat solution to manage receive alarms from burglar and or fire alarm panels with Teldat MIP or FireLite IPDACT IP alarm trans modules Each VisorALARM PLUS receiver supports to 3,000 alarm panels and provides the industry most set of features including line supervision 512 bit and a three level redundancy system for the highest availability and reliability levels Integration with central automation software packages is almost immediate as VisorALARM PLUS receiver is able to emulate the industry common receiver protocols Communication between the PLUS receiver and the automation server com is done via a regular serial connection Scalability Simultaneous management for up to 3,000 MIP IPDACT IP remote devices Line monitoring Monitors connectivity status with all regis devices Network access monitoring Monitors the status of its net access to avoid generating false technical alarms under communications failure situation Support for dynamic and static IP addresses on the MIP and IPDACT devices Encryption Uses 512 bit AES encryption algorithm for all with installed IP modules Communicates alarms to the automation server via a connection using ContactID format and emulating Sur Radionics or Ademco receiver protocols Smart card Saves all configuration information on an exter smart card that can be used for immediate system under crash recovery situations Secondary receiver support Two VisorALARMs PLUS be setup in a primary secondary configuration for high and redundancy options Teldat MIP and units in the field will report to the primary unit and Events 300 Failure in the receiver ventilators 350 mIP is not sending polling traffic 356 Loss of connectivity in the central line 358 Main receiver has detected the backup receiver down 394 mIP begins to poll the backup receiver 395 Configuration error in the mIP 396 Main receiver has activated 397 Receiver has lost IP communication 398 Backup receiver has activated 399 Backup receiver has activated as a result of the receiver being down 531 A new mIP has been registered 633 Free space in the alarms buffer is above 25 634 Free space in the alarms buffer is below 25 635 Alarms buffer is full cid 129 A3 40 automatically switch to the secondary receiver if the pri becomes unavailable Secondary receiver automatic synchronization The pri and secondary VisorALARM PLUS receivers support TRCP protocol that allows them both to maintain identical files Back up receiver automatic takeover An additional VisorALARM PLUS receiver can be placed in the network as the primary receiver programming the unit takeover the identity of the primary receiver under the that it becomes unavailable Local and remote management tools Local management a console type serial connection available management is implemented via a telnet session Real time embedded operating system for maximum per and protection against viruses and hacker attacks Display and keyboard Management monitoring and alarm directly from your receiver front keys and display Alarm automation server connection The VisorALARM receiver can be connected to the automation server via regular serial connection cable included with the unit Alarm automation configuration The VisorALARM PLUS Surgard Radionics and Ademco protocols for easy with any alarm automation software SIS IBS Microkey etc Configuration scripts VisorALARM PLUS allows configu scripts to be uploaded via the console or telnet ses Most common configuration scripts are available at Security website allowing the user to download the and use them as templates to add customer specific Backup Options VisorALARM PLUS receiver implements advanced network functionalities which allow all installed MIPs or IPDACT to send alarms and polling signals to a main and a second VisorALARM PLUS receivers Teldat MIP IPDACT units report to the secondary destination in those cases where the VisorALARM PLUS fails Teldat MIP IPDACT units will to report to the backup VisorALARM PLUS for both and line supervision signals until the communication with main receiver is restored In cases where the backup Visor PLUS also fails the MIP connects the telephone line to Teldat MIP IPDACT unit so that it can be used as an addi level of backup allowing the panel to transmit the alarms the telephone network 03 19 2010 Page 1 of 2 Supervision Support VisorALARM PLUS receiver gets supervision messages Teldat MIPs All registered Teldat MIP IPDACT units periodic keep alive or polling signals to the receiver which answers with an acknowledgement response The status of the registered Teldat MIP IPDACT units is periodically A 350 Contact ID alarm code is generated and sent to automation server for those Teldat MIPs who have not noti their availability Communication trouble In order to avoid VisorALARM PLUS generating hundreds or thousands of failure alarms when there is a general IP traffic failure the VisorALARM PLUS monitors the network to a stable and well known internet address if the echo to this address fail a 356 Contact ID alarm code is gen Loss of central polling PLUS Specifications INTERFACE Flash memory for up to 42000 alarms storage 1 WatchDog output 1 Programmable output 2 Programmable inputs 2 UD Serial Ports INTERFACE Local Terminal V 24 9600 8 N 1 without flow control Connector DB 9 female Telnet Password protected POWER Voltage 100 240 VAC Current 0.5 1.0 AMP Frequency 47 63 Hz INTERFACE Protocols Ethernet b802.3 Ethernet blue book Speed 10 Mbps 100 Mbps 100BaseT Connector RJ45 female SPECIFICATIONS Room temperature On 41 to 131 Off 4 F to 140 Relative humidity On 8 to 85 Off 5 to 90 Insertable drivers V 24 V 35 X 21 DTE DCE INTERFACES Protocols FRAME RELAY X 25 PPP SDLC X 28 N Ports 2 printer automation software Speed 200 to 2048 Kbps Connector DB 25 female Emulation Surgard Radionics 6500 and Ademco 685 AND WEIGHT Type Desktop 2U or standard 19 Rackmount L x W x H 12.21 x 16.34 x 3.39 inches Weight 8.82 lbs AND APPROVALS UL1610 Central Station Burglar Alarm Units UL1076 Proprietary Burglar Alarm Units and Systems ULC ORD C1076 M1986 Proprietary Burglar Alarm Units CAN ULC S304 M88 Central and Monitoring Station Burglar UL864 Control Units and Accessories for Fire Alarm Units INFORMATION VisorALARM Plus Receiver with LCD display and keypad Alarms is a registered trademark of Honeywell International Inc is a registered trademark of the Teldat Corporation by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Fire cid 129 Lite Alarms Phone 800 627 3473 FAX 877 699 4105 2 of 2 DF 60279 C cid 129 03 19 2010