Gamewell-FCI 7100 Series A E Specifications - Stand-Alone (PDF)

File Preview
File Preview
Click below to download for free

Text Preview

Gamewell FCI 9020 0480 2006 jaw 2007 Clintonville Road Connecticut 06472 633 1311 Free 484 7161 484 7118 Guide Specification Notes This product guide specification is written according to the Construction Specifications CSI 3 Part Format as described in The Project Resource Manual CSI Manual of Practice section must be carefully reviewed and edited by the Architect or Engineer to meet the of the project and local building code Coordinate this section with other specification and the Drawings Delete all Notes when editing this section numbers and titles are from MasterFormat 1995 Edition with numbers and titles from 2004 Edition in parentheses Delete version not required 13850 28 31 00 DETECTION AND ALARM SYSTEM Notes This section covers Gamewell FCI 7100 Series fire alarm system Consult Gamewell for assistance in editing this section for the specific application 1 INCLUDES VDC analog addressable multiprocessor based fire alarm system addressable sensors shall include but not be limited to Control equipment Control panel Addressable modules Audible and visual notification appliances Conduit wiring and fittings necessary to provide complete and operable system SECTIONS Series Fire Alarm Control 28 31 00 1 9020 0480 2006 jaw Notes Edit the following list of related sections as required for the project List other sections work directly related to this section Section 13800 Building Automation and Control Section 13900 21 00 00 Fire Suppression Section 27 15 00 Fire Alarm Communications Horizontal Cabling Notes List standards referenced in this section complete with designations and titles This does not require compliance with standards but is merely a listing of those used National Fire Protection Association NFPA NFPA 12 Standard on Carbon Dioxide Extinguishing Systems NFPA 12A Standard on Halon 1301 Fire Extinguishing Systems NFPA 13 Installation of Sprinkler Systems NFPA 15 Standard for Water Spray Fixed Systems for Fire Protection NFPA 16 Standard for the Installation of Foam Water Sprinkler and Foam Water Spray NFPA 16A Standard for the Installation of Closed Head Foam Water Sprinkler Systems NFPA 17 Standard for Dry Chemical Extinguishing Systems NFPA 17A Standard for Wet Chemical Extinguishing Systems NFPA 70 National Electrical Code NFPA 72 National Fire Alarm Code NFPA 90A Standard for the Installation of Air Conditioning and Ventilating Systems NFPA 101 Life Safety Code NFPA 750 Standard on Water Mist Fire Protection Systems NFPA 2001 Clean Agent Fire Extinguishing Systems Underwriters Laboratories UL UL 268A Standard for Smoke Detectors for Duct Application UL 864 9th Edition Standard for Control Units and Accessories for Fire Alarm Systems AND STANDARDS Equipment shall be listed by Underwriters Laboratories Inc approved by Factory Mutual or as accepted by the Authority Having Jurisdiction AHJ Codes The fire alarm system in its entirety shall be in compliance with all applicable fire and codes and comply with requirements of the local Authority Having Jurisdiction over systems UL Standards System shall comply with applicable provisions of the following UL standards classifications UL 864 9th Edition UOJZ Control Units System Control Units Releasing Device Series Fire Alarm Control 28 31 00 2 9020 0480 2006 jaw NFPA Standards System shall comply with applicable provisions of the following NFPA UOXX Control Unit Accessories System Accessories Releasing Device Service NFPA 72 Fire Alarm Systems Fire Alarm Systems Central Station Fire Alarm Systems Remote Station Fire Alarm Systems Proprietary Fire Alarm Systems NFPA 90A NFPA 101 DESCRIPTION Multiprocessor Based system shall be of multiprocessor design to allow maximum flexibility of capabilities operation Field Programmable system shall be capable of being front panel programmed or by means of Field Program FCP allowing programming to be downloaded via portable RS 232C Serial Output supervised RS 232C serial port shall be provided to operate remote printers and or terminals accept downloaded program from portable computer or provide 80 readout of alarms troubles location descriptions time and date Communication shall be the standard ASCII code operating at 9600 baud rate Control by Event CBE Program Operation of manual station or automatic activation of any smoke sensor heat sensor or zone shall activate system control by event program to cause Notes Specify one of the following first three sentences notification appliances to sound in continuous pattern and strobes to flash All notification appliances to sound in a temporal pattern and strobes to flash All notification appliances to sound in march time code pattern and strobes to flash Shut down all air handling units as specified herein ALARM LED shall flash and panel sounder shall pulse on the 80 character alphanumeric panel display description of specific device in alarm Display shall be of the liquid crystal type LCD visible in the dark or in poor light conditions Notes Specify any of the following four sentences as required Close all magnetically held doors automatically Series Fire Alarm Control 28 31 00 3 9020 0480 2006 jaw Energize programmed solenoids for activating deluge or preaction systems additional functions as specified herein or as indicated on the drawings the Fire Department General System Operation When an alarm occurs the control panel shall indicates alarm condition until manually may be acknowledged by pressing ALARM ACKNOWLEDGE switch shall silence the panel sounder and change the ALARM LED from flashing to lit notification appliances may be silenced by operating the SIGNAL SILENCE switch shall steadily light the SYSTEM SILENCED LED a subsequent alarm is activated notification appliances shall resound until again Once silenced all notification appliances may be restored by operating the SIGNAL switch Waterflow zones shall be non silenceable Alarm Verification detector alarm verification shall be a standard option on all zones while allowing dry contact device such as manual stations and heat detectors to create immediate feature shall allow smoke sensors that are installed in environments prone to or unwanted alarms to operate according to following sequence System Ready Prior to smoke sensor alarm Smoke Sensor Alarm At time 0 Window 15 seconds A distinctive pre alarm indication shall be Reset 5 seconds Occurs at end of pre alarm window Alarm Verification Window 90 seconds The system shall respond to a second from same smoke sensor as a system alarm Ready No alarm verification verification sequence is suspended once the system alarm is activated Alarm Signals alarm signals shall automatically latch or lock in at the control panel until the operated is returned to normal and the control panel is manually reset signals shall be programmable for operation when required by the Having Jurisdiction When used for waterflow the SIGNAL SILENCE switch be bypassed Electrically Supervised signaling line circuit and notification appliance circuit shall be electrically supervised opens shorts and ground faults Occurrence of a fault shall activate the system trouble circuitry but shall not interfere with operation of the circuit that does not have a fault condition yellow SYSTEM TROUBLE LED shall light and the system audible sounder shall sound when trouble is detected in the system Failure of power opens or short on notification appliance or signaling line circuits disarrangement in system wiring Series Fire

Related Files