Gamewell-FCI ADP Series Duct Detector

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-adp-series-duct-detector-6945087321.pdf
Type PDF
Size 874.78 KB
Downloads

Text Preview

ADP Series DUCT Intelligent N etw orks Fire Control Instruments ADP Series photoelectronic air duct sensors are capable of sensing in air velocities from 100 to 4,000 per minute 0.5 to 20.32 m sec ADP series features low flow tech that enables duct smoke detection a broad range of airflow Many difficult to solve applications occur in low airflow applications where reliable smoke is critical ADP low flow tech can detect smoke at air speed ve of 100 feet per minute or greater continuing the same reliable perfor to 4,000 feet per minute ADP Series sensor samples air cur passing through a duct and gives de performance for shutdown of fans and air conditioning systems pre the spread of toxic smoke and fire through the protected area intelligent sensors communicate are continuously monitored through the line circuit Sensor sensitivity caused by dirt temperature or are reported to the panel allow compensation algorithms to maintain sensor set sensitivity An advance at the panel specifies the sen address allowing for selected main to be performed as needed alarm annunciation can be by using the RA400Z Re Annunciator or the RTS451 or Remote Test Station Both devices allow testing of the sensor a remote location ADP series low flow duct sensors designed for simplified installation and maintenance The modular construc allows for easy cleaning and uncom field replacement of the UL rec power and sensor boards ADP non relay has outputs for a LED displa y and remote test It incorporates zener diodes to con power for communications to other ADP is a 2 wire device that requires line circuit power only ADP R with relay has powered for remote LED indication with remote test switch and audible sounder form auxiliary contacts can be as a relay version or jumpered mimic the non relay version It has a cover tamper trouble signal ADP R is a 4 wire device that requires signaling line circuit power and either or 120 240VAC for proper op Air Velocity rating from 100 to 4000 per minute 0.5 to 20.32 m sec Patented Telescopic Sampling Tube Easily accessible Code Switches Outside Mounting Tabs Easy and quick mounting to Round Rectangular Ducts from 1 meters wide Easy to clean UL Recognized Field replaceable and Sensor boards Transparent Cover for convenient Inspection UL 268A listed ISO 9001 Company are provided for information only and are intended to be used for installation purposes and are to be accurate However no responsibility is by Fire Control Instruments for their use subject to change without notice 2003 All Rights Reserved 1.0 1of 5 Honeywell Company Intelligent N etw orks Series diagram for ADP Duct Smoke Sensor a UL Listed control panel diagram for ADP Duct Smoke Sensor with optional RA400Z break tab on back of RA400Z when used with ADP diagram for ADP Duct Smoke Sensor with RTS451 RTS451KEY are provided for information only and are not intended to be used for installation purposes and are believed to be accurate no responsibility is assumed by Fire Control Instruments for their use Specifications subject to change without notice 2003 All Rights Reserved Southwest Park Westwood MA 02090 USA Tel 781 471 3000 Fax 781 471 3099 www firecontrolinstruments com CONTROL INSTRUMENTS Honeywell Company 9020 0567 Ver 1.0 Page 2 of 5 Intelligent N etw orks Series diagram for ADP R Duct Smoke Sensor using a UL Listed control panel Jumper J1 shunt must be installed for 2 wire applications J1 shunt must be removed for power PCB diagram for ADP R Duct Smoke Sensor with optional PA400 diagram for ADP R Duct Smoke Sensor with RA400Z diagram for ADP R Duct Smoke Sensor with are provided for information only and are not intended to be used for installation purposes and are believed to be accurate no responsibility is assumed by Fire Control Instruments for their use Specifications subject to change without notice 2003 All Rights Reserved Southwest Park Westwood MA 02090 USA Tel 781 471 3000 Fax 781 471 3099 www firecontrolinstruments com CONTROL INSTRUMENTS Honeywell Company 9020 0567 Ver 1.0 Page 3 of 5 Intelligent N etw orks Series to 131 0 to 55 to 93 relative humidity non condensing to 158 30 to 70 C 4000 ft min 0.5 20.32 m s SERIES LOW FLOW SPECIFICATIONS Temperature Range Humidity Range Temperature Range Air velocity Weight 1.5 kg 1.8 kg 37 cm 14 cm 7 cm to 32 VDC 24 VDC one communication every 5 seconds with LED SPECIFICATIONS Range Current enabled Current Loads mA mA mA Max mA Max SPECIFICATIONS Requirements using no accessories supply voltage standby current alarm current response tim e up time VDC mA mA to 10 sec sec VAC 50 60HZ mA RMS mA RMS to 10 sec sec 50 60Hz mA RMS mA RMS to 10 sec sec VAC 50 60Hz mA RMS mA RMS to 10 sec sec Ratings auxiliary contacts DPDT A 30 VDC A 277 VAC 0.75 power factor VA 249 VAC 0.4 power factor HP 120 VAC HP 240 VAC contact SPST A 30 VDC resistive switching current for auxiliary contact must be 100 mA DC minimum 5 VDC Current Loads at 24 VDC are provided for information only and are not intended to be used for installation purposes and are believed to be accurate no responsibility is assumed by Fire Control Instruments for their use Specifications subject to change without notice mA Max mA Max mA Max mA mA mA Southwest Park Westwood MA 02090 USA Tel 781 471 3000 Fax 781 471 3099 www firecontrolinstruments com CONTROL INSTRUMENTS Honeywell Company 2003 All Rights Reserved 9020 0567 Ver 1.0 Page 4 of 5 Intelligent N etw orks Series INFORMATION No addressable low flow photoelectronic non relay duct smoke sensor addresable low flow photoelectronic with relay duct smoke sensor sampling tube duct widths 1 sampling tube duct widths 2 sampling tube duct widths 4 sampling tube duct widths 8 photoelectric sensor board power board for ADP R w relay power board for ADP w o relay test station test station w key LED Sounder Note Device cannot be wired directly to ADP non relay filters magnet cap for metal sampling tube cap for plastic sampling tube photo insect screen plastic sampling tube are provided for information only and are not intended to be used for installation purposes and are believed to be accurate no responsibility is assumed by Fire Control Instruments for their use Specifications subject to change without notice 2003 All Rights Reserved Southwest Park Westwood MA 02090 USA Tel 781 471 3000 Fax 781 471 3099 www firecontrolinstruments com CONTROL INSTRUMENTS Honeywell Company 9020 0567 Ver 1.0 Page 5 of 5

Related Files