Gamewell-FCI MCS-4-Warn Multi-Criteria Detector

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-mcs-4-warn-multi-criteria-detector-4091573268.pdf
Type PDF
Size 670.42 KB
Downloads

Text Preview

Addressable Devices Series MCS 4 Warn Multi Criteria Detector with Four Unique Sensing Elements latest addition of the Gamewell FCI Advanced Detection product line integrates complementary technologies into one device to convey accurate fire sensing to locations where fire fighter response time is critical The Gamewell FCI is an advanced multi criteria plug in detector that assembles four sensing elements into one unit Electrochemical cell technology that monitors carbon monoxide CO produced by fires Infrared IR sensing that measures ambient light levels and flame signatures Photo electric smoke detection Thermal detection for temperature monitoring is designed to be used with the Gamewell FCI E3 Series and S3 Series fire alarm panel only integration of continuous monitoring for all four major elements of a fire allows to create a detector that responds more quickly to an actual fire with highest immunity to nuisances This advanced multi criteria detector operates at high immunity level It is designed to detect changing elements identify nuisance and adjust the sensor accordingly to reduce false alarms on board intelligence runs advanced algorithms that dynamically adjust detection to respond to the inputs from the sensors enabling instant response as conditions change panel automatically changes sensor thresholds sensor gain time delays combinations sampling rates and averaging rates If any sensor the detector automatically adjusts the sensitivity of the remaining sensors and produces a fault condition CO cell has an expected lifetime of approximately six years It is not a field replaceable component An internal timer signals the control to signal the approach of the CO cell end of life Upon expiration you should contact the system supplier to arrange for replacement of unit Detection is not compromised when the CO cell expires The algorithms automatically adjusts to properly weigh the inputs from the heat and IR sensors The CO cell is specifically deployed as a component of smoke detection in this device This device is not Listed for applications in which standalone CO detection is required for life safety IR light sensor recognizes specific situations such as welding and makes adjustments rapidly to further reduce the potential for nuisance The thermal detection function uses thermistor technology with a software corrected linear temperature response to offer exceptional alarm immunity and excellent fire detection Applies four separate Employs advanced Incorporates CO BENEFITS elements Has the highest alarm Includes twin LED that provide visibility that and respond multiple inputs Comprises fully infrared to support a fire alarm for the fastest to slow smoldering Provides the automatic compensation of a sensor and a CO Offers superior EMI Programs LEDs to be controlled to latch on or Contains a built in test Uses six levels of Diagram 1 illustrates the MCS 4 Warn Advance Multi Criteria 1 MCS 4 Warn Advance Multi Criteria Detector Information Advanced multi criteria detector with four sensing elements Flanged mounting base Intelligent sounder base capable of producing a variety tone patterns including ANSI Temporal 3 Compatible with System Sensor synchronization protocol Intelligent sounder base Temporal 3 or Continuous Isolator base maximum of 25 devices between bases Relay base Velociti Series MCS 4 Warn is designed to comply the following standard Standard UL 864 9th Edition LISTINGS AND APPROVALS listings and approvals apply to the modules in this document In some cases certain or applications may not be listed by certain agencies or listing may be in process factory for latest listing status S1195 7272 1703 0173 9001 Certification a complete listing of all approvals and please visit Series and Velociti are trademarks and is a trademark of International Inc is a registered trademark Underwriters Laboratories document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice Series MCS 4 Warn Technical Specifications Specifications Diameter 4.0 10 16 cm Height 2.4 6.1 cm Weight 4.6 ounces Temperature Range 32 F to 100 F 0 C to C Humidity Range 10 to 93 relative humidity Specifications Supply Voltage 15 to 32 VDC Current 200 uA at 24 VDC no Current LED on 7 mA at 24 VDC Settings Suggested Applications 1 1 per foot 30.48 cm of smoke Very clean Used in Laboratories 2 2 per foot 30.48 cm of smoke Clean Used in offices 3 3 per foot 30.48 cm of smoke Moderately environments Used in hotel rooms dorm rooms 4 3 per foot 30.48 cm of smoke with different processing and weighting of sensor elements in hotel rooms near a shower or boiler rooms 5 4 per foot 30.48 cm of smoke Used in rooms kitchens paint shop 6 Thermal alarm at 135 F 57 C After the CO cell has reached the end of life any set to Level 3 or Level 4 will default to Level 5 and 5 will drop to 3 CO Cell Sensitivities following sensitivities apply to devices with expired cells 1 1 per foot 30.48 cm of smoke Very clean Used in Laboratories 2 2 per foot 30.48 cm of smoke Clean Used in offices 5 3 per foot 30.48 cm of smoke Moderately environments Used in hotel rooms dorm rooms 6 Thermal alarm at 135 F 57 C AND HUMIDITY RANGES system meets NFPA requirements for operation at 0 49 120 and at a relative humidity 93 2 noncondensing at 32 2 90 3 the useful life of the system s standby batteries the electronic components may be adversely affected extreme temperature ranges and humidity Therefore is recommended that this system and its peripherals be in an environment with a normal room of 15 27 80 more information more about Gamewell FCI Velociti Series MCS 4 Warn other products available by visiting www Gamewell FCI com Gamewell FCI Clintonville Road CT 06472 1610 E 11 17 Honeywell International Inc

Related Files