Gamewell-FCI MCS-Accl 2F Multi-Criteria Sensor
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-mcs-accl-2f-multi-criteria-sensor-2706984531.pdf |
---|---|
Type | |
Size | 655.69 KB |
Downloads |
Text Preview
Addressable Devices Series MCS ACCLIMATE2F Analog Addressable Sensor Gamewell FCI Velociti Series MCS ACCLIMATE2F sensor is an analog multi sensing low profile sensor designed for use with the Gamewell analog addressable fire alarm control panels MCS ACCLIMATE2F sensor uses a combination of photoelectronic and thermal technologies that are designed to increase immunity to false alarms Unlike addressable devices the MCS ACCLIMATE2F sensor has a in the sensor head that processes alarm data As a result the MCS sensor automatically adjusts its sensitivity without requiring operator where the MCS ACCLIMATE2F sensor is especially useful include office schools college campuses manufacturing and industrial facilities and else where the use of a particular area may change One day a conference tomorrow a kitchen the next day a copy machine room the MCS sensor automatically adjusts its sensitivity to the environment Velociti Series uses a communication protocol that substantially increases the of communication between the sensors and Gamewell FCI analog addressable alarm controls These devices operate in a grouped fashion If one of the devices the group has a status change the panel microprocessor stops the group poll and the single device with the status change The net effect is response speed to five times greater than earlier designs plug in sensors use a separate base to simplify installation service and maintenance A special tool allows maintenance to plug in and remove sensors without using a ladder the base on a box which is at least 1.5 3.8 cm deep Suitable mounting base boxes include 4.0 10.2 cm square box 3.5 8.9 cm or 4.0 10.2 cm octagonal box Single gang box except relay or isolator base the B200S or B200SR base mounted on an octagonal or a 4.0 10.2 cm square box the B224RB or B224BI base mounted on a 3.5 8.9 cm octagonal box or a 4.0 10.2 cm octagonal or square box Because of the inherent supervision provided by the SLC end of line resistors are not required Wiring or branches are for Style 4 Class wiring BENEFITS Compatible with the analog panels Designed with a sleek design Suitable for installation ducts Has a visual rotary switch range of Built in functional test activated by an magnet Low temperature at 45 7.2 10 5.5 Displays bi color LEDs Provides green whenever sensor is and light red on alarm Offers the relay and sounder options photo and technology Capable of heat only mode enabled a special command the E3 Series or Series panel and alarms are then Automatically adjusts levels the need for intervention programming increases heat Spacing recommends that the spacing sensors used in compliance with NFPA 72 Note MCS ACCLIMATE2F sensor has the unique ability adjust sensitivity according to the environment on heat and smoke levels Avoid installing these in locations that are susceptible to high or fluctuating temperatures An example of an application would be near or in line with the of a heating unit Information Multi Criteria Analog Addressable and Options Plug in sensor base without flange 4.1 10.4 cm diameter Flanged mounting base 6.1 15.5 cm diameter Flanged mounting base bulk pack 6.1 15.5 cm diameter Relay Base Plug in sensor base with relay SPDT rated 2 amps 30 VDC resistive Terminals Up to 14 AWG 2.0 mm2 coil latching relay 1 Form C contact UL CSA 0.9 A 125 VAC inductive 0.9 A 110 VDC inductive 3 A 30 VDC resistive 6.1 cm diameter Isolator Base Maximum 25 devices between bases 6.1 15.5 cm diameter Intelligent sensor sounder base 6.875 17.5 cm diameter Standard sounder base 6.875 17.5 cm diameter Remote LED Annunciator Black detector covers box of 10 Series MCS ACCLIMATE2F Technical Specifications MCS ACCLIMATE2F is designed to comply with following standard Standard UL 268 Listings and Approvals listings and approvals apply to the modules in this document In some cases certain or applications may not be listed by certain agencies or listing may be in process factory for latest listing status S1913 3023594 FDNY COA 219 02 E Vol VI 7272 1703 0121 9001 Certification a complete listing of all approvals and please visit Series Velociti and are registered of Honeywell Inc is a registered trademark Underwriter Laboratories document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice 1.7 45 mm Height 4.1 104 mm installed in the B501 base 6.1 155 mm installed in the B210LP base 6.875 17.46 cm installed in the B200 B200SR base weight 5.0 oz 142 g Temperature Range 32 F to 100 F 0 to C Velocity 0 4,000 ft min 1219.2 m min for installation in ducts Humidity 10 93 non condensing Ratings Fixed temperature setpoint 135 F C Specifications Range 15 32 volts DC Current 0003A 24 VDC One communication 5 seconds with LED blink enabled Alarm Current 0065A 24 VDC LED lit AND HUMIDITY RANGES system meets NFPA requirements for operation at 0 49 120 and at a relative humidity 93 2 noncondensing at 32 2 90 3 the useful life of the system standby batteries the electronic components may be adversely affected extreme temperature ranges and humidity Therefore is recommended that this system and its peripherals be in an environment with a normal room of 15 27 80 more information more about Gamewell FCI Velociti Series MCS and other products available by visiting Gamewell FCI Clintonville Road CT 06472 1610 H 11 17 Honeywell International Inc