Gamewell-FCI MMI-6S Interface Module

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-mmi-6s-interface-module-4576038912.pdf
Type PDF
Size 1.26 MB
Downloads

Text Preview

Building Intelligent Networks The Multi Mod Six Zone Interface mod MMI 6S provides six Style B Class B three Style D Class A supervised Initi Device Circuits IDCs suitable for use U L Listed conventional 2 wire smoke as well as any normally open con device See A ddendum to FCI Installa Manuals 9000 0427 for all L Listed devices The MMI 6S connects to the Signaling Line SLCs of the FCI 7200 FV7200 7100 Series fire alarm control panels of the MMI 6S Initiating Device Cir occupies its own address on the SLC allowing each to be fully pro in its control by event sequence operation The address of the first Initiating Device is set with a pair of rotary dials Each circuit is automatically assigned its own subsequent address The MMI 6S includes an address disable jumper to allow a maximum of two unused to be turned off to free these ad for other purposes An additional of jumpers selects either Style B or D circuit configurations Each Circuit has its own status LED that to indicate proper polling and turns steady when the output has been acti Two Multi Mod Series units can be in one BB 2 cabinet A dditional options include the CH 6 chas that can accommodate six Multi Mod modules The CH 6 chassis can be in a custom cabinet or can be in the BB 6 cabinet allowing up to Multi Mod Series modules in one cabi The Multi Mod Series is ideal for applica where centralized location of circuits re required As many as 60 Initiating De Circuits may be located in a cabinet is only 12.63 H x 24 W x 6.5 D in saving valuable wall space in me rooms and electrical closets and cost of installation ZONE MMI 6S Module Provides Six Style B Class B or T h ree Style D Class A Individually A dd ressable Individually Programmable Initiating Device Circuits for Use with U L Listed 2wire Conventional Smoke Sensors and Normally Open Contcat Devices Wiring Terminal Blocks allow Ease of Installation and Servicing Blocks can Accommodate 12 to 18 AW G W i re On board Jumper Configura tion Feature allowing One or Two Moni toring Circuit A dd resses to be Disabled for use with 7100 and 7200 Series Fire Alarm Control Panels LED Indicators for Retrofit Applications Many as Thirty Six Initiating Device Circuits in One 12 x 24 x 6.5 Cabinet Mounting Cabinets A vailable fo r Two BB 2 Cabinet to Six BB 6 Cabinet MMI 6S Modules ISO 9001 Company are provided for information only and are intended to be used for installation purposes and are to be accurate However no responsibility is by Fire Control Instruments for their use Speci subject to change without notice 2002 All Rights Reserve d 1.1 1of 4 Intelligent Networks Device Circuit Terminal Blocks Style B or Three Style D SUPPLY ADDRESS ADDRESS ADDRESS to SLC and Out ability disable One or Initiating Circuits ADDRESS 0 BASE ADDRESS 1 BASE ADDRESS 2 BASE ADDRESS 3 BASE ADDRESS 4 BASE ADDRESS 5 A ddress Switches First A ddress Five A ddresses assigned to Iniating Device LEDs per Initiating Circuit to indicate Polling turn on steadily indicate Activation are provided for information only and are not intended to be used for installation purposes and are believed to be accurate owever no responsibility is assumed by Fire Control Instruments for their use Specifications subject to change without notice 2002 All Rights Reserved Southwest Park Westwood MA 02090 USA cid 127 Tel 781 471 3000 cid 127 Fax 781 471 3099 cid 127 www firecontrolinstruments com CONTROL INSTRUMENTS 9020 0547 VER 1.1 Page 2 of 4 Intelligent Networks High Wide 2 unit capacity High Wide with CH 6 6 unit capacity are provided for information only and are not intended to be used for installation purposes and are believed to be accurate owever no responsibility is assumed by Fire Control Instruments for their use Specifications subject to change without notice 2002 All Rights Reserved Southwest Park Westwood MA 02090 USA cid 127 Tel 781 471 3000 cid 127 Fax 781 471 3099 cid 127 www firecontrolinstruments com CONTROL INSTRUMENTS 9020 0547 VER 1.1 Page 3 of 4 Intelligent Networks Voltage Current Current IDC Wire Resistance Range BB 2 BB 6 Supply Voltage DC Voltage Ripple Voltage Current VDC mA mA with all six LEDs on Ohms F to 120 F 0 to 49 C to 85 Non condensing H x 5.8 W x 1.25 D 17.3 x 14.7 x 3.18 cm H x 9.25 W x 3.32 D 31.12 x 23.5 x 8.43 cm H x 24 W x 6.5 D 32.08 x 60.96 x 16.51 cm Volts Power Limited Volts rms maximu m mA per Module APPROVALS 864 INFORMATION NUMBER 6 Zone Interface Module Box 2 Unit Box 6 Unit requires CH 6 Mounting Chassis are provided for information only and are not intended to be used for installation purposes and are believed to be accurate owever no responsibility is assumed by Fire Control Instruments for their use Specifications subject to change without notice 2002 All Rights Reserved Southwest Park Westwood MA 02090 USA cid 127 Tel 781 471 3000 cid 127 Fax 781 471 3099 cid 127 www firecontrolinstruments com CONTROL INSTRUMENTS 9020 0547 VER 1.1 Page 4 of 4

Related Files