Gamewell-FCI MS-95 Manual Station

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-ms-95-manual-station-7549102638.pdf
Type PDF
Size 992.19 KB
Downloads

Text Preview

Description MS 95 Addressable Manual Pull Station is designed be used with Gamewell 600 Series Analog Addressable Panels The MS 95 satisfies architectural requirements a manual alarm initiating device It contains a switch which internally connected to the electronic interface that is required individual addressable identification to and from the Fire Control Panel Addressable Manual Station is shock and vibration resis A toggle switch of rugged construction provides excep high resistance to accidental operation from sudden The MS 95 can be used for both surface and semi flush It is of compact design blends in well with all build interiors yet is easily recognized in an emergency situation Addressable Manual Pull Station complies with UL Stan 38 for manual stations station is activated by pulling forward a readily identifiable alarm lever marked Upon activation this lever in the alarm position and remains so until manually reset is accomplished by releasing the hinged front cover manually resetting the toggle switch Release of the cover accomplished by a releasing screw or if utilizing the Key Re Option a Gamewell CAT60 Key optional breakglass rod may be used with all stations The design prevents jamming of the station and there no danger to the operator from broken particles of glass Space provided within the station housing for storage of an addi replacement glass rod MS 95 connects directly to the Analog Addressable circuit two wires The electronic circuitry has been designed to data that can be interpreted as three output operations Quiescent Operation Alarm Operation and Trouble In its quiescent mode of operation the pull station monitor the switch for alarm conditions A trouble occurs when the pull station is addressed by the con panel and either reports back a trouble response or does respond at all With the standard priority interrupt feature MS 95 will report its condition virtually instantaneously in Analog Addressable Control Panels of the MS 95 Manual Station is accomplished the setting of a single DIP switch easily accessible on device printed circuit board The DIP switch is used to set address of the device All other programming is accom at the control panel either through the use of a laptop or through the Operator Display Manual Alarm Station Listed CSFM MEA FM Approved with Gamewell 600 Series Analog Control Panels Programmable Durable Construction Compact design blends with surroundings Recessed pull lever prevents accidental operation Self clearing breakglass option Surface or semi flush installation Double action option Key reset option Meets ADA requirements Rev 0701 1 1 Resetting the station after operation shall require opening the cover for access to the alarm switch The manual fire station shall be a Gamewell Analog Addressable Manual Station model number MS 95 and shall be U L listed manual pull station shall be adaptable for surface or semi installation In addition there shall be provisions for a break glass mechanism Specification analog addressable manual pull station shall contain the interface circuitry required for individual device iden alarm reporting and trouble supervision It shall com to the main control panel via the analog addressable The single action non coded station shall consist of a aluminum housing fitted with a pull out lever which operated locks in position after activating an alarm initi contact Current Current Temperature Humidity with Key Reset Option Backbox P N 28762 Information Number If no Part Numbers are shown use Model Numbers Diagram 49 Non Condensing Aluminum Alarm Red smooth gloss enamel Raised cast letters are high Target background for pull lever is white gloss enamel high by 3 wide by 2 deep from the backplate high by 3 wide by 2 deep from the backplate high by 3 wide by 23 8 deep Analog Addressable Manual Pull Station Double Action Option Key Reset Option Key Reset Double Action Option Backbox Surface Mount Backbox Surface for Key Reset Options and wiring information are provided for information only and are believed to be accurate Gamewell assumes no responsi for their use Data and design are subject to change without notice Installation and wiring instructions shipped with the product always be used for actual installation For more information contact Gamewell Gamewell Company Pleasant St MA 01721 in the USA 508 231 1400 888 347 3269 508 231 0900 2001 Rev 0701 1 2

Related Files