Gamewell-FCI MS Series, Manual Pull Station

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-ms-series-manual-pull-station-8607514923.pdf
Type PDF
Size 670.66 KB
Downloads

Text Preview

MS Series Manual Alarm Stations 1 MS 2 2 MS 2H 3 MS 6 Single and Dual Action Versions Tumbler Lock for Test and Reset Keyed Alike with FCI Panels Rugged Metal Construction Positive Indication of Operation over 180 Viewing Surface or Semi flush Mounting Shock and Vibration Resistant Optional SUPPRESSION SYSTEM RELEASE Version MS 2L MS 2H Optional DPST Switch MS 2 D MS 2 MS 2H MS 2 manual fire alarm stations are dual action These stations require that the outer door be lifted expose the actuation door which is then pulled forward operate the alarm toggle switch The actuation door is locked in the readily observable position reset the station a key common to Gamewell FCI con panels must be inserted and turned turn clockwise the station Closing the station resets the switch optional breakglass rod is available for positive indica of station operation MS 2L Institutional of the Model MS 2L institutional station requires a special key be used to release the actuation door it can be operated MS 2 D Multiple Contact MS 2 D features a DPST switch for multiple signaling wire lead connections MS 6 Single Action MS 6 station is a single action device requiring only pulling of the action door to release the compressed switch It is available either with terminals MS 6T wire leads MS 6 station resets in the same manner as the MS 2 The key is common to FCI control panels MS 2 MS 6 Extruded 6063 T5 aluminum MS 2 MS 6 Type MS 2 MS 6 Material Ratings MS 2 MS 6 toggle push button plated bronze or copper amp max 30 VDC resistive amp max 30 VDC anodize overall MS 2 MS 6 H x 3.4 W x 2.8 D cm x 8.64 cm x 7.11 cm MS 2 MS 6 MS 6T MS 2 MS 6 GAMEWELL FCI are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 by Honeywell International Inc All rights reserved www gamewell fci com Rev J page 1 of 2 Information Number Description Dual Action fire alarm station Dual Action station with SYSTEM RELEASE Institutional fire alarm station Dual action station with DPST Single action station wire leads Single action station terminals Surface backbox for MS 2 MS 6 sta of two replacement breakglass for MS 2 station 4 MS Series Installation Rev J page 2 of 2 Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118

Related Files