Gamewell-FCI NetSOLO® Classic

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-netsolo-classic-4823106795.pdf
Type PDF
Size 769.15 KB
Downloads

Text Preview

Voice Evacuation Classic Networked Multi Channel and Amplification Voice Evacuation System NetSOLO Classic System is a revolutionary advance in emergency voice system design NetSOLO Classic employs the proven technology of the Series fire alarm control panel and expands it to accomplish emergency bulk voice evacuation two way fire fighter communications and building application is a true peer to peer token passing networked system capable of supporting up to individual nodes All system status control by event sequences audio voice and fire fighter telephone communications are sent between nodes over a cable or single pair of wires NetSOLO Classic node can be spaced along the network a maximum distance of feet 914.4 m over an unshielded twisted pair of wires or up to an 8 dB loss fiber optic cable Built in isolation at each node permits Style 4 Style 6 and 7 network configurations Classic is simple to configure for any project requirement A complete Classic application can be assembled from just two types of nodes the Net SOLO and the INCC C Command Center plus bulk amplification Classic is capable of many sophisticated sequences of operations The Classic Field Configuration Program is based on Boolean logic statements AND OR NOT and XOR logic operators These statements can be combined produce additional Boolean operators such as NAND NOR XNOR etc A set of timing functions can also be attached to any input output statement for staggered reset of fan control relays time delayed alarm time delayed alarm activation automatic system silence etc BENEFITS All communication Network data transfer Each voice gateway Classic and control by sequences over cable or a pair of twisted wires Distributed including 7 wiring allow components to normal with no loss function during line fault at 625K baud Ideal for a wide range of system including or campus Integrates 7100 fire alarm panels and centers to a complete evacuation with up to 64 supports up to ASM 16 Switch for a total of switches which are software Redundant command with and fire handset easily by adding State of the art digital processor DSP audio and Audio channels of up to AA Series per channel Messages easily field via laptop Advanced Boolean such as OR NOT NOR delay and functions via Voice Gateway INI VGE Voice Gateway controls it own audio capable of controlling up to twenty AA Series watt 70.7 VRMS or 120 watt 25 VRMS audio Each amplifier has one speaker circuit that be wired Style Y Class B or Style Z Class A Each can produce its own tone or message of other system amplifiers INI VGE uses advanced Digital Signal Processing technology for audio compression and filtering feature allows the NetSOLO Classic to produce a audio transmission while it simultaneously the network bandwidth when it transmits instantaneous response Background noise is filtered during voice paging and fire communications which increases the and eliminates the need for push to talk INI VGE can accommodate up to sixteen different with a total combined duration of three Each message can be field installed via a computer and can be in the form of a voice or an evacuation tone INI VGE also provides a fire fighter telephone riser addressable signaling line circuit connecting to phone jacks or warden stations through as as 16 AOM TELF modules In addition each SLC can support up to 32 speaker circuits the AOM 2SF for single channel applications NetSOLO 7100 NetSOLO is a micro processor based fire control panel with two analog addressable line circuits SLC Each 7100 is equipped an Intelligent Network Interface module for twisted wire INI 7100 UTP or a of wire and fiber optic cable INI 7100 Another option includes an integral Digital Alarm Transmitter DACT supporting most reporting formats Network Command Center INCC C Intelligent Network Command Center Classic serves as the point of interface between an and the system audio evacuation fire intercom and building network The INCC C a single address on the NetSOLO Classic A typical INCCC assembly consists of the an Intelligent Network Interface Voice Gateway up to six Addressable Switch Modules ASM 16 or Remote LED Driver Modules include a voice paging microphone and a fire intercom handset that connects to the INI Each INCC C can support up to six ASM 16 or modules Each ASM 16 has sixteen push switches that has a maximum capacity of 96 per INCC C command center Every switch three associated LEDs colored green yellow and These switches and their LEDs are fully to serve any system function desired can control the following components audio speaker circuits notification appliance circuits addressable relay outputs fire fighter phone control circuits or any special application that might be required INCC Cs can be configured into the Broadband network to serve as a independent command center for their area or as remote command centers mimicking part or in whole the function of a main command 1 illustrates the NetSOLO Classic System configuration NetSOLO with two appliance each rated 24 VDC Class 2 Two line circuits 394 devices Class 2 6 Class A with CAOM Module Command Center shown with microphone and firefighter an INI VGE Voice Gateway ASM Addressable Switch Modules each with programmable addressable switches and programmable indicating LEDs red yellow per switch Each INI VGE an audio channel amplifier provides a appliance circuit 100 Watts 70.7 non power limited 120 watts 25 VRMS 2 power limited integral Digital Communicator DACT for or network wide reporting cable or two wires nodes Up to 8 dB loss fiber optic 3,000 ft 900m with wire signaling line circuit with 16 and 32 AOM MUXF modules AOM TELFs Style 6 Class A standard 2 power limited wires between INCC C bulk amplifier cabinet be in rigid conduit not exceed 20 feet Amplifier Cabinet 1 NetSOLO Classic System Configuration 2 illustrates the NetSOLO Classic System node configuration Annunciators LCD 7100 5 Global display for all events if set to Region 6 SLC AOM TELFs 32 AOM MUXFs Control Devices for SLC No2 if used phone riser Speaker applicance circuits watts max 25 VRMS w 50 watts standby ft max between nodes using wire Db loss max between nodes using fiber optic cable 4 Control Devices for SLC No2 if used SLC AOM TELFs 32 AOM MUXFs phone riser Speaker applicance circuits watts max 25 VRMS w 50 watts standby Integral DACT 1 Control Typical for No2 if used 3 SLC AOM TELFs 32 AOM MUXFs Annunciators LCD 7100 5 Global display for all events if set to Region 2 phone riser Speaker applicance circuits watts max 25 VRMS w 50 watts standby 2 NetSOLO Classic System Node Configuration 7 8 5 if wired A Style 6 or 7 only INFORMATION Number

Related Files