Addressable Devices 95 Bases Addressable Sensors Gamewell FCI XP 95 Series bases are designed to operate with the Gamewell FCI Series and ILI95 E3 Series analog addressable fire alarm control panels The XP Series bases provide superior flexibility for the installation of the Gamewell FCI family of addressable detectors Whether the project requires a 4.0 10.16 cm or sounder base there are a variety of XP95 Series base options available to meet building aesthetics constraints retrofit limitations or functional needs The device is held in the base This feature ensures that the device address will not be no matter how often a detector is replaced and the address verifies a match between the device type and the device address XP95 analog addressable sensor head is compatible with a wide variety of XP 95 ranging from any of the following one piece low profile units four wire relay sounder bases that can be controlled individually or as a group XP95 Series detector bases are designed to enable sensors to be plugged in with force and to have a fit Relay and sounder bases can be and controlled individually or controlled by a group in response to the alarms can use the patented XPert addressing card to program the address setting for Series 95 Sensors After you insert the card into the sensor base the address is relayed to the sensor If you change the sensor it does not require programming because the address remains on the XPert Card that is in the base You can do all other sensor specific programming at the Fire Control Panel FACP If you use the XPert addressing card it ensures that you install only the correct device types in given locations after cleaning or other operations Series 95 addressable mounting bases are compatible with any one of the Series 95 sensors The base is designed with a wide interior to offer easy access to wires and terminals and allow the sensor to fit in only one way To plug in the sensor rotate the base in a clockwise motion You can insert the XPert addressing card into the designated outlet on the mounting base Use the XPert addressing card to program and maintain the sensor address XP95 B4 base 4.0 10.16 cm will mount directly to the following components 3.5 8.89 cm octagonal box Raco 110 or equal 4 10.16 cm octagonal box Raco 125 or equal with a round cover plaster ring Raco 727 or equal The other Series 95 bases 6.0 15.24 cm will mount directly to any of the following 3.5 8.89 cm octagonal box Raco 110 or equal 4.0 10.16 cm square backbox Raco 190 or equal Information 4.0 10.16 cm mounting base with XPert addressing card 6.0 15.24 cm relay base four wire with XPert addressing card 6.0 15.24 cm ultra low profile EZ fit mounting base with XPert addressing card 6.0 15.24 cm mounting base with XPert addressing card and audible alarm sounder in the base Remote LED 24 VDC Additional blank XPert addressing cards BENEFITS Compatible with the Base options include Gamewell 4.0 10.16 cm or analog FACPs Compatible with all XP95 detection 4.0 10.16 cm octagonal box Raco 125 or equal in the sensor XPert card Sets the address by Stores the device 95 Bases 600 Series ILI95 E3 Series 6.0 15.24 cm ultra low profile bases feature one way fit with low insertion force 6.0 15.24 cm relay base 4 wire Audible alarm sounder bases controlled individually or by group Series 95 Bases are designed to comply with the standard STANDARDS Standard 864 9th Edition LISTINGS AND APPROVALS listings and approvals apply to the modules in this document In some cases certain or applications may not be listed by certain agencies or listing may be in process Consult factory for the latest listing status Listed S1195 7300 1703 0158 9001 Certification a complete listing of all approvals and please visit is a registered trademark Underwriters Laboratories document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice of origin U S A 95 Bases Technical Specifications 10.16 cm Base XP95 B4 Apollo 45681 210 Current N A Current N A Rating N A Level N A Terminals Yes 15.24 cm Base XP95 B6EZ Apollo 45681 250 Current N A Current N A Rating N A Level N A Terminals Yes Base MB RLYT AA Current 0.0036 A Current 2 uA Rating 0.04 A 125 VAC resistive loading Level N A Terminals Yes Base MB SDRT AA Current 0.030 A Current 2 uA Rating N A Level 85 dB 10 ft 3.048 m Terminals Yes SPECIFICATIONS contractor shall furnish and install as indicated on plans either dual chamber ionization Gamewell FCI XP95 I or photoelectric Gamewell FCI model smoke sensors analog addressable multi XP95 M or electronic thermal sensor Gamewell model XP95 T with one of the several addressable base available options The combination sensor and twist lock mounting base shall be UL Listed UL Listed as compatible with the Gamewell FC 600 or ILI95 E3 Series analog addressable fire alarm panels The base shall permit free interchange of heads without requiring any additional wiring or programming of the head or base Gamewell FCI Clintonville Road CT 06472 1610 E 05 19 Honeywell International Inc

Related Files