Gamewell-FCI SL-DA4R Analog Addressable Duct Smoke Detectors
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-sl-da4r-analog-addressable-duct-smoke-detectors-7956148203.pdf |
---|---|
Type | |
Size | 765.23 KB |
Downloads |
Text Preview
Description SL DA4R Series Smoke Duct Detector is the latest addressable innovation for early detection of and products of combustion present in air moving HVAC ducts in Commercial Industrial and Resi applications The unit is designed to prevent the or spread of smoke by air handling systems and blowers Complete systems may be shut down the unit on board alarm contact in the event of smoke The SL DA4R is designed and built to meet all code requirements as well as the NFPA and ICC regarding HVAC supply and return duct smoke Output terminals are provided for a wide range remote accessories such as horns strobes remote sta indicators and test key switches or push buttons SL DA4R includes many features that represent true from current generation duct smoke detectors approach has closely followed and expanded throughout the SL This philosophy provides a new level of efficiency in value to both the installer servicer and end Our attention to detail has yielded a host of features as well as a multi application perfor level as yet unmatched in the industry The key fea below detail many of the customer driven innovations in the SL DA4R Series Innovative product with unsurpassed customer service equals the combination for all of your projects Architects Specifications Air duct smoke detectors shall be Air Products and Con Inc SL DA4R Series For photoelectric detectors the model number is SL The detectors shall be listed by Underwriters per UL 268A The detectors shall operate at air velocities from 100 per minute to 4,000 feet per minute and at tempera of no greater than 140 60 Visual indication of alarm must be provided on the front A manual alarm relay test switch located on the front of device shall be provided Detector head shall not require additional filters or which must be maintained and control board include both a standby and alarm visual indica Series Addressable Duct Smoke Detectors Low FLow No Tools Series Technology Both Ionization and Photoelectric models for velocities between 100 4000 ft min Both Ionization and Photoelectric models listed for high temperature Operating voltages 24VAC or 24VDC Units supplied with slide in XPERT Card for easy device addressing Patent pending Required front or rear loading and remov Patent pending Port Valve allows for aerosol smoke testing sampling exhaust tubes cover removal Clear cover fitted with four captive Required thumb cover removal trouble indication terminal block for easier wiring Steady red LED on detector head indicates alarm operation More wiring space than competitive models allows easy retrofit in many applications without additional Over 15 remote accessories available Duct wall gaskets on back of enclosure are pre installed Compatible with the WP 2000 weatherproof enclosure Built in alarm relay test switch 27 UROX7 S2829 GAMEWELL FCI are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 by Honeywell International Inc All rights reserved www gamewell fci com Rev B1 page 1 of 2 Architects Specifications Continued The housing shall contain a detector base which will photoelectric or ionization detector heads as well a means of detector addressing Terminal connections shall be of the screw type a mini of 6 screw 12 to 22 AWG compatible Termi shall be provided for remote pilot remote alarm strobe horn and remote test switch All wir must comply with local codes and regulations A method of smoke testing the detector without remov the cover must be provided All unit and remote accessory connection designations be permanently affixed to the unit Cover and sampling exhaust tube installation or must not require the use of tools Sample and exhaust tubes shall be capable of removal from the front and or rear of the detector for Continued Unit includes green pilot and red alarm visual indicators External mounting tabs do not require cover removal to Colored cover gasket indicates proper cover seal Compact lightweight size means easy handling lower costs One set of 15A form alarm contacts Large terminal connection screws XP95A interchangeable UL268 photoelectric Advanced detector head design yields internal dust fil ionization heads No additional screens or filters to clean Compatible with fire alarm systems utilizing Apollo and or Discovery protocol and Photoelectric versions available Complete wiring details permanently attached to unit Accessory Wiring 1 Terminal Connections 2 Remote Accessory Wiring Information Compatibility FACP using Apollo XP95 and or Discovery protocols Part Number Board Power Tubes STN 1.0 STN 2.5 set form rated at 15 Amps 125VAC STN 5.0 10 Amps 277VAC STN 10.0 VAC VDC Contact Rating Alarm Contacts Resistive Load mA mA tube for 12 or less duct width tube for 6 to 2.5 duct width tube for 2.5 to 5.0 duct width tube for 5.0 to10.0 duct width 24VAC or 24VDC Inductive Load Velocity Temperature SL DAA N SL DAA P Element Net Weight 7 Amps 30VDC HP 125 250VAC NC HP 125 250VAC NO to 4,000 ft min to 150 0 to 66 to 140 0 to 60 95 RH Non Condensing Non Freezing or stranded 12 to 22 AWG terminals SL DA4R N Ionization Americium 241 0.9 Do not expose to corrosive atmospheres plastic backbox clear plastic cover 94V 0 1 2 L x 4 1 2 W x 2 1 4 H lbs Rev B1 page 2 of 2 Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118