Gamewell-FCI Wheelock ET Series Speaker Strobes

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-wheelock-et-series-speaker-strobes-7052389146.pdf
Type PDF
Size 803.37 KB
Downloads

Text Preview

Building Intelligent N etw orks has enhanced the ET Series Speakers and Speaker combinations These speakers are designed to meet the critical of the life safety industry for voice tone signaling These dual voltage 25 volt multiple tap from 1 8 to 8 watts systems now incorporate a new design which results in more in standard electrical backboxes Series Speakers and Speaker Strobes incorporate a new speaker mounting for faster and easier installation with built in level adjustment feature and a aesthetically pleasing two screw grille Additionally the ET Series Speaker models now incorporate the reduced inrush RSS Series Non Sync Sync synchronization of the strobe is achieved when used with the SM or DSM Sync Module Series Speaker Strobes are designed maximum performance reliability and while meeting or ex the latest requirements of NFPA National Fire Alarm Code ANSI 117.1 National Standard of Accessible Usable Buildings and Facilities and Standard 1971 Standard for Signaling for the Hearing Impaired ET Strobes when properly specified installed in accordance with NFPA standards can provide the equiva facilitation allowed under ADA Acces Guidelines ADAAG General Sec 2.2 by meeting or exceeding the il which results from the ADA strobe intensity of 75 candela at feet 15.24 m This is an illumination 0.030 lumens per square foot Series Speaker Strobes are UL listed indoor use ceiling and wall mounting Standard 1971 for Signaling Devices the Hearing Impaired and Standard 1480 Speaker Appliances They use a Xenon with solid state circuitry enclosed a rugged LEXAN lens to provide reliability for effective visual Designed to meet or exceed NFPA ANSI and ADA Accessibility Guide Meets OSHA 29 Part 1910.165 High efficiency speakers designed for output at minimum wattage 400 to 4,000 Hz frequency range Field selectable taps for 25 or 70 VRMS from 1 8 watt up to 8 watts in steps Sealed back speaker construction extra protection and improved Easy installation with In Out screw using 12 AWG 3.25 mm 18 AWG 0.75 mm wiring ET Series Speaker Strobe models are with the new RSS Series Non Strobes in 15 15 75 30 75 110 candela for wall mounting and 75 and 100 candela for ceiling mount When used in conjunction with Wheelock SM or DSM Sync Mod these non sync sync strobes pro a synchronized strobe flash for with ADA guidelines con photosensitive epilepsy The 15 75 candela wall mounted are listed at 15 candela under standard 1971 and meet 75 candela on axis for ADA guidelines low current draw All strobe inputs compatible with stan reverse polarity type supervision of wiring by an alarm panel The new speaker mounting plate faster easier installation in package styles for flush semi or surface mounting to standard backboxes Special slots are for ease in leveling speaker and models ET 1010 or ET 1080 Series models for vandal resistant die cast and speaker strobes is a registered trademark of GE Plastics a subsidiary of General Electric Company Wheelock Series SERIES SERIES Series Strobe Series Strobe XXI Speakers Fire ISO 9001 Company are provided for information only and are intended to be used for installation purposes and are to be accurate However no responsibility is by Fire Control Instruments for their use subject to change without notice 2003 All Rights Reserved 1.0 1 of 4 Honeywell Company Series Intelligent N etw orks QUICK REFERENCE Strobe devices synchronized multiple DSM Modules wiring shown of twenty 20 DSM Modules DIAGRAMS all models Speaker and Strobe operate non sync or sync Strobe devices synchronized DSM Module dual Class Style Z circuit NO audible silence feature details on using SM or DSM Sync Modules to Wheelock data sheet S3000 Wheelock installation instructions for SM or P83177 for DSM are provided for information only and are not intended to be used for installation purposes and are believed to be accurate no responsibility is assumed by Fire Control Instruments for their use Specifications subject to change without notice 2003 All Rights Reserved Southwest Park Westwood MA 02090 USA Tel 781 471 3000 Fax 781 471 3099 www firecontrolinstruments com CONTROL INSTRUMENTS Honeywell Company 9020 0579Ver 1.0 Page 2 of 4 Intelligent N etw orks Series Wheelock for installation instructions Wheelock P83567 and general information sheet Wheelock P82380 for these products materials undergo periodic changes It is important that you have current information on these products These materials contain information that should be read prior to specifying or installing these products including current required by all devices connected to system primary and secondary power sources ratings on NAC circuits to handle maximum inrush or peak currents from all devices on those circuits Composite flash rate from multiple strobes within a person field of view Note Use strobes only on circuits with continuously applied operating voltage Do not use strobe on coded or interrupted applied the voltage applied to these products must be within their rated input voltage range of 110 100 candela strobe products in sleeping areas in office areas and other specification and installation issues circuits in which the applied voltage is cycled on and off as the strobe may not flash Conductor specifications Conductor size AWG length and capacity should be taken into consideration prior to design and of these products particularly in retrofit installations TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN INSTALLATION APPLICATION AND OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION WHICH RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND OR OTHERS products must be used within their published specifications and must be PROPERLY specified applied installed operated and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year more often and in accordance with local state and federal codes regulations and laws Specification application installation maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest Fire Protection Association NFPA Underwriters Laboratories UL National Electrical Code NEC Occupational Safety and Administration OSHA local state county province district federal and other applicable building and fire standards guide regulations laws and codes including but not limited to all appendices and amendments and the requirements of the local having jurisdiction AHJ ENGINEER SPECIFICATIONS speaker appliances shall be Wheelock ET Series Speakers and Speaker Strobes or approved equivalent The speakers shall listed under Standard UL 1480 for Fire Protective Service Speaker appliances equipped with strobes shall additionally be Listed UL 1971 Signaling Devices for the Hearing Impaired speakers shall include both 25 and 70 VRMS input

Related Files