Gamewell-FCI XP95-T Analog Addressable Thermal Sensor

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-xp95-t-analog-addressable-thermal-sensor-0613498257.pdf
Type PDF
Size 622.30 KB
Downloads

Text Preview

Addressable Devices Addressable Thermal Sensor Gamewell FCI XP95 T Analog Addressable Thermal Sensor is designed to with the Gamewell FCI 600 Series and ILI95 E3 Series fire alarm control FACPs The Series XP95 T thermal sensor digitally transmits its address and chamber analog temperature value to the FACP for analysis The thermal are designed with open webs in the housing This feature allows the free of air to flow around the exposed thermistor XP95 T thermal sensor constantly monitors its sensing element as well as its electronics The results are digitally reported along with the unit address the integral communication electronics located in the sensor head The sensor monitors the temperature by using a single thermistor network which a voltage output that is proportional to the external air temperature This is processed and conditioned by an on board advanced technology ASIC When this feature digitally transmits the ambient temperature data to the FACP can identify the trouble and alarm conditions of the XP95 sensors at the FACP status information of each sensor is analyzed for off conditions by the panel If the sensor reports a condition that matches its programmed trouble the FACP will report that the sensor is in trouble and will follow its response sequence Likewise if the status reported matches the alarm the FACP will follow the programmed alarm response for the specific device alarm When a sensor is in alarm the integral LED in the sensor housing will light XP95 T thermal sensor is calibrated to return a normal air temperature analog to the FACP at 77 The device connects to a two loop circuit carrying both and a 117 to 28 VDC supply voltage and it is insensitive to loop connection A remote LED indicator can be connected The device is compatible with or group relay and sounder bases BENEFITS Compatible with the Gamewell analog addressable alarm control FACPs 600 Series ILI95 E3 Series Fits the following ultra profile E Z fit 4 inch 10.16 cm 6 inch 15.24 cm Includes an audible sounder base Has an optional remote Provides fixed point or functions Stores the address in Sets the address by the Offers a timed sensor base Comprises thermal addressing card Contains a two color increase causes an alarm LED XP95 T is designed to comply with the following STANDARDS Standard 864 9th Edition LISTINGS AND APPROVALS listings and approvals apply to the modules in this document In some cases certain or applications may not be listed by certain agencies or listing may be in process Consult factory for the latest listing status Listed 2527 Approved Approved 149 99 E 7270 1703 0156 9001 Certification a complete listing of all approvals and please visit is a registered trademark Underwriters Laboratories document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice of origin U S A Technical Specifications Current 250 uA LED Current 4 mA Alarm Output 4 mA 5 VDC Range 4 to 154 Humidity non condensing 0 to 95 Spacing Smooth ceiling 60ft 18.288 to walls 25 ft 7.62 m Sensor Performance Features Thermal sensors have a thermal adjustable range from 25 to 90 77 to 194 in increments Thermal Sensors have a thermal rate of rise this feature is enabled in programming if the XP95 sensor increases the temperature by greater than 15 less than one minute an alarm activates SPECIFICATIONS contractor shall furnish and install where indicated the plans electronic thermal sensors with one of the available addressable mounting base options combination sensor head and twist mounting shall be UL Listed and UL Listed as compatible with Gamewell FCI 600 Series or ILI95 E3 Series analog fire alarm control panels base shall permit free interchange of sensor heads requiring any additional wiring or programming of sensor head or base The sensor shall contain an LED that shall latch in when the unit goes into It shall be the Gamewell FCI model XP95 T Gamewell FCI Clintonville Road CT 06472 1610 D 04 19 Honeywell International Inc

Related Files