Gamewell-FCI XP95PD ID Analog Addressable Duct Smoke Sensor
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-xp95pd-id-analog-addressable-duct-smoke-sensor-2189045736.pdf |
---|---|
Type | |
Size | 654.78 KB |
Downloads |
Text Preview
Addressable Devices XP95 ID IDR Addressable Duct Smoke Detectors Gamewell FCI XP95 Series is designed to operate with the Gamewell FCI 600 and ILI95 E3 Series analog addressable fire alarm control panels The XP95 analog addressable duct smoke detectors provide early detection of smoke and with combustion present in air moving through an HVAC duct In the event smoke detection fans blowers and complete systems may be shut down or in a fire alarm mode by the fire alarm control panel FACP Gamewell FCI analog addressable duct smoke detectors can use either photoelectric or ionization sensor heads The external alarm is a light emitting diode LED that is visible from the clear plastic cover A manual reset switch appears on the front of the sensor smoke detectors are also available with auxiliary relay contacts The relay two additional wires for power and they will activate when the sensor reaches levels All wiring must comply with the local codes and regulations XP95 Duct Detectors digitally transmit their address and the chamber anal og value to FACP for analysis perform air sampling use the two tubes which extend into the duct An exhaust of one standard length 7.5 19.05 cm is provided with the sensor housing sampling tubes which must be ordered separately are supplied in three lengths 2.5 5 or 10 feet 0.762 1.524 or 3.048 m install the Duct mounting use a template and the furnished four sheet metal The duct detectors are compatible with the analog loops on the Gamewell 600 Series or the ILI95 E3 Series Analog Addressable fire alarm control panels the address setting to program the XP95 Duct Smoke Sensors To program the XP95 Duct Smoke Sensors use the XPert addressing card insert it into the sensor base After you insert the sensor head into the base the address is automatically relayed to the sensor Changing sensor does not require additional programming since the address remains on the XPert card located in the base All other sensor specific is accomplished at the FACP Information Two wire air duct ionization smoke detector 24 VDC RW AAN Two wire air duct photoelectric smoke detector 24 VDC RW AAP Remote LED alarm indicator two VDCs used with XP95 PD and XP95 ID Four wire air duct ionization smoke detector 24 VDC with relay RW ARN Four wire air duct photoelectric smoke detector 24 VDC with relay RW ARP Remote LED alarm indicator 24 VDCs used with relay versions Remote test station with alarm LED used with relay versions Sampling tube 2.5 feet 0.762 m Sampling tube 5 feet 1.524 m Sampling tube 10 feet 3.048 m Ionization sensor head replacement Photoelectric sensor head replacement Duct detector enclosure WP 1 See Data Sheet P N CS 2308 Series Contains BENEFITS Compatible with the Gamewell analog fire alarm panels 600 Series ILI95 E3 Series photoelectric or heads Address is set by the addressing card Address is stored in the base Offers two wire supply Built in a rugged steel insensitive Provides a very low current Includes an LED alarm on the head Relay version available optional remote unit with a clear cover Contains large connection No additional screens filters to clean or Offers three standard lengths available 2.5 0.762m 5 1.524 m 10 ft 3.048 m Remote alarm LED available XP95 ID IDR Technical Specifications XP95 PD PDR XP95 ID IDR4 are designed to with the following standard STANDARDS Standard 864 9th Edition LISTINGS AND APPROVALS listings and approvals apply to the modules in this document In some cases certain or applications may not be listed by certain agencies or listing may be in process Consult factory for the latest listing status Listed S1195 Approved Approved 73 92 E 7272 1703 0155 Photo 7271 1703 0157 Ion 9001 Certification a complete listing of all approvals and please visit is a registered trademark Underwriters Laboratories document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice of origin U S A Temperature 32 F to 120 0 to 49 10 to 85 R H 18 gauge steel backbox clear plastic cover 10.0 H x 8.25 W x 2.25 D 25.4 H x 21.0 W x 5.7 D cm Net Weight 4.0 lbs 1.814 kg Template and necessary hardware supplied Element Ionization versions only Americium 241 0.9 micro curies Factory set ion or adjustable via the IF600 panel photoelectric Velocity 300 to 4,000 feet per minute Differential 0.01 to 1.2 inches 1.524 to 20.320 per second of water Current 340 uA 280 uA LED Current 4 mA 2 mA Alarm Output Range 20 mA maximum diode Versions Only Contacts Two dry Form C contacts Contact Ratings 10 A 24 VDC resistive maximum Voltage 24 VDC Current 0.010 A 24 VDC current 0.055 A 24 VDC SPECIFICATIONS contractor shall furnish and install where indicated the plans analog addressable air duct smoke The sensors shall be Listed by Underwriter per UL 268A and UL Listed as compatible the Fire Alarm Control Panel FACP The sensors operate at air velocities from 300 to 4,000 feet to 1219.20 m per minute The smoke sensor shall an integral LED that shall latch in when the unit into alarm mounted at a 30 slant to provide a wide angle manual reset test switch shall be located on the front of device The housing shall contain a sensor base which accept photoelectric or ionization heads All wiring comply with local codes and regulations The duct housing shall have a metal chassis with a clear cover and complete mechanical installation may performed without removal of the cover The duct detector shall be the Gamewell FCI model XP95 or XP95 PD R analog addressable duct smoke Gamewell FCI Clintonville Road CT 06472 1610 E 04 19 Honeywell International Inc