Gamewell-FIC NetSOLO® Broadband Fire Alarm Specification

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fic-netsolo-broadband-fire-alarm-specification-3498160275.pdf
Type PDF
Size 772.49 KB
Downloads

Text Preview

Version 1.0 Broadband Fire Alarm Voice Evacuation System Specification No 9020 0581 2003 Rights Reserved in the USA Southwest Park Westwood MA 02090 USA Tel 781 471 3000 781 471 3099 ww firecontrolinstruments com 1 GENERAL CONDITIONS Contractor shall furnish all equipment materials tools labor drawings and all associated necessary for a complete networked fire alarm system ready for operational in accordance with the requirements of the NFPA 72 and the authorities having The Contractor shall provide all devices and equipment required by the drawings specifications The Contractor may not delete any equipment or devices without and approval of a request for information detailing all deletions The Contractor may not change types of coverage without submission and approval of a request for detailing the reason for change ensure reliability and complete compatibility all Items of the Fire Alarm System including panels power supplies as well as all initiating and indicating devices shall be listed by Control Instruments FCI by Underwriters Laboratories inc UL and shall bear the Partial listing shall not be acceptable equipment and installation supervision furnished shall be listed as an approved distributor Fire Control Instruments and shall produce proof of factory training within 14 calendar of award of the contract DESCRIPTION successful bidder shall furnish and install a complete Networked Fire Alarm System with all programming and connections as described on the drawings and this document The System shall be wired in a supervised 2 wire fashion utilizing classes and styles as NFPA 72 The System shall be a TRUE peer to peer network including panels 7100 interface cards INI annunciators LCD 7100 Network Command Center INCC Network Transponders INX double action manual stations MS 2 photoelectric smoke detectors ASD PL addressable duct detectors ADS P monitor modules AMM 2 control modules AOM 2R S Multiple input modules MMI 10 multiple output modules MMO 6R S Strobes and Combination horn strobes wiring connections to devices boxes junction boxes and all other necessary material and mounting hardware A system shall conform to the latest editions of the following codes and standards Life Safety Code 101 Fire Alarm Codes NFPA 72 National Electrical Code 70 Americans with Disabilities Act ADA NFPA 12 Carbon Dioxide Extinguishing Systems NFPA 12A Halon 1301 Fire Extinguishing Systems NFPA 13 Installation of Sprinkler Systems NFPA 15 Water Spray Fixed Systems NFPA 16 Deluge Foam Water Sprinkler Systems NFPA 16A Installation of Closed Head Foam water Sprinkler Systems NFPA 17 Dry Chemical Extinguishing Systems NFPA 17A Wet Chemical Extinguishing Systems NFPA 72 National Fire Alarm Code Central Station Fire Alarm Systems 7100D Local Fire Alarm Systems Auxiliary Fire Alarm Systems Remote Station Fire Alarm Systems 7100D Proprietary Fire Alarm Systems 7100D NFPA 90A Installation of Air Conditioning and Ventilating Systems Life Safety Code NFPA 101 Safety to Life from Fire in Buildings and Structures NFPA 750 Water Mist Fire Protection Systems NFPA 2001 Clean Agent Fire Extinguishing Systems WARRANTY A manufacturer shall guarantee all system equipment for a period of one 1 year from date of final acceptance with the appropriate contractors for interfacing to building systems as required on drawings including but not limited to Elevator interface HVAC interface and Security interface 10 copies of shop drawings and product data sheets in accordance with all sections of document submittal shall include certification from Fire Control Instruments FCI verifying that the is an authorized agent who is qualified and trained by the manufacturer in the installation operation and service of the system Contractor shall include the following information in the equipment submittal A complete list of all supplied equipment including the quantities and model numbers used along with catalog data sheets on each component Complete drawings including the following Floor plans showing all control panels annunciators power supplies initiating devices appliances and control devices Wiring diagrams showing points of connection and terminals used for connection to the devices and panels This shall include recommendations and precautions for installing the system devices of each control panel and power supply showing interconnections field terminations including contact ratings and interfaces to other Battery capacity calculations for each control panel and power supply OPERATION AND MAINTENANCE MANUALS Before final acceptance testing submit a two 2 complete sets of operation and manuals along with two 2 sets of as built drawings The operation and manuals shall include Building name and address The name and phone number of the contractor system manufacturer and system The actual operation and maintenance manual supplied by the system manufacturer ALARM SYSTEM FUNCTIONALITY Provide a complete electrically supervised distributed networked analog addressable fire and control system with analog initiating devices integral multiple channel voice and fire fighters phone system The Fire alarm system shall consist of multiple voice channels with no additional hardware to add additional channels The system shall incorporate multiprocessor based control panels including model FCI Intelligent Network Transponders INX and Intelligent Network Command INCC communicating over a peer to peer token ring network with a capacity of to 64 nodes Each 7100 node shall incorporate two 2 Signaling Line Circuits SLC with the capacity support up to 99 analog addressable detectors and 98 addressable modules per SLC SLC loops shall be capable of supporting laser detectors ASD LS with a sensitivity as low as 2 percent obscuration and the MCS Acclimate detector with intelligent and integral thermal sensor All Voice Data and Fire Fighters phone Riser shall transmit over a single pair of wires or optic cable Each Intelligent Network Transponder shall be capable of providing 16 distributed voice Fire Fighter Phones connections an SLC loop for control devices and an network interface Each Network Node shall incorporate Boolean control by event programming including as minimum AND OR NOT and Timer functions The control panels shall have the capability to accept firmware upgrades via connection a laptop computer without the requirement of replacing microchips The network shall be based on a peer to peer token ring technology operating at 625 K utilizing style 4 6 or 7 wiring The network shall include the capability of utilizing either twisted pair wiring A pair of optic cables up to 200 microns or both to maximize flexibility in system Each network node shall have the capability of being programmed off line using Windows software supplied by Fire Control Instruments FCI Each node shall also have the of being downloaded by connecting the laptop computer into any other node in system Each network node shall have the capability of being grouped with any number of nodes to produce a allowing that group of nodes to act as one while the peer to peer functionality Master Slave configurations are not acceptable Each network node shall have the capability of annunciating all events within its annunciating all events from the entire network on both the front panel LCD without additional equipment Each network node shall have the capability having an integral dialer that can report events either its region or the entire network to a single account Each 7100 panel shall have the capability of storing its entire program and allow the to activate only the devices that are installed during construction without further of the system Each system shall be provided with four 4 levels of password protection with up to 16 passwords 2 PRODUCT OPERATION 7100 Series Networked panel system

Related Files