Honeywell VISTA-20P Programming Manual (PDF)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | honeywell-vista-20p-programming-manual-pdf-9760135482.pdf |
---|---|
Type | |
Size | 992.95 KB |
Downloads |
Text Preview
Downloaded from www Manualslib com manuals search engine ADEMCO VISTA SERIES VISTA 20P VISTA 20PSIA VISTA 15P VISTA 15PSIA Security Systems Programming Guide K5305 1PRV5 10 04 Rev A firealarmresources com from www Manualslib com manuals search engine ENTER PROGRAMMING MODE using an alpha keypad connected to the control A POWER UP then press and at the same time within 50 seconds of powering up this method must be used if was used to exit program mode OR B Initially key Installer Code 4 1 1 2 plus 8 0 0 PROGRAMMING MODE COMMANDS Task Command Explanation Go to a Data Field Press Field Number followed by the required entry Entering Data When the desired field number appears simply make the required entry When the last entry for a field is entered the keypad beeps three times and automatically displays the next data field in sequence If the number of digits that you need to enter in a data field is less than the maximum digits available for example the phone number fields 41 42 enter the desired data then press to end the entry The next data field number is displayed Review a Data Field Press Field Number Data will be displayed for that field number No changes will be accepted in this mode Deleting an Entry Press Field Number Applies only to fields thru 46 94 and pager fields Initialize Download ID Press Initializes download ID and subscriber account number Reset Factory Defaults Press Sets all data fields to original factory default values Zone Programming Press Zone characteristics report codes alpha descriptors and serial numbers for 5800 RF transmitters Function Key Programming Press Unlabeled keypad keys known as ABCD keys for special functions Zone Programming Expert Mode Press Same options as 56 mode but with fewer prompts Intended for those familiar with this type of programming otherwise 56 mode is recommended Output Device Mapping Press Assign module addresses and map individual relays powerline carrier devices Output Programming Press 4229 or 4204 Relay modules Powerline Carrier devices or on board triggers Zone List Programming Press Zone Lists for relay powerline carrier activation chime zones pager zones etc Alpha Programming Press Zone alpha descriptors Exit Program Mode with installer code lockout Press Exits programming mode and prevents re entry by Installer Code 8 0 0 To reenter programming mode the system must be powered down then powered up Then use method A above See field 88 for other 98 Program mode lockout options Exit Program Mode Press Exits programming mode and allows re entry by Installer Code 8 0 0 or method A above SPECIAL MESSAGES OC OPEN CIRCUIT no communication between Keypad and Control EE or ENTRY ERROR ERROR invalid field number entered re enter valid field number After powering up AC dI disabled or Busy Standby and NOT READY will be displayed after approximately 4 seconds This will revert to a message in approximately 1 minute which allows PIRS etc to stabilize You can bypass this delay by pressing 0 If E4 or E8 appears more zones than the expansion units can handle have been programmed The display will clear after you correct the programming TABLE OF DEVICE ADDRESSES This Device Uses Address Reports as Enabled By RF Receiver 00 100 56 zone programming input device type entry AUI 1 01 101 Automatic if AUI enable field 189 enabled for AUI 1 AUI 2 02 102 Automatic if AUI enable field 189 enabled for AUI 2 Long Range Radio 03 103 automatic if output to long range radio field 29 enabled 4286 Voice Module 04 104 automatic if phone module access code field 28 enabled Zone Expanders 4219 4229 module 1 for zones 09 16 module 2 for zones 17 24 module 3 for zones 25 32 module 4 zones 33 40 module 5 zones 41 48 07 08 09 10 11 107 108 109 110 111 56 zone programming input device type entry then automatic if zone no 9 16 entered as AW type or relay assigned automatic if zone no 17 24 entered as AW type or relay assigned automatic if zone no 25 32 entered as AW type or relay assigned automatic if zone no 33 40 entered as AW type or relay assigned automatic if zone no 41 48 entered as AW type or relay assigned Relay Modules 4204 module 1 module 2 module 3 module 4 12 13 14 15 112 113 114 115 79 output device programming device address prompt entered at device address prompt entered at device address prompt entered at device address prompt entered at device address prompt Keypads keypad 1 keypad 2 keypad 3 keypad 4 keypad 5 keypad 6 keypad 7 keypad 8 16 17 18 19 20 21 22 23 n a n a n a n a n a n a n a n a data field programming as listed below always enabled all sounds enabled data field 190 data field 191 data field 192 data field 193 data field 194 data field 195 data field 196 5800TM Module 28 n a automatic These module addresses apply to VISTA 20P only Addressable devices are identified by plus the device address when reporting Enter report code for zone 91 to enable addressable device reporting default reports enabled See field 199 for addressable device ECP 3 digit 2 digit identification keypad display options 2 firealarmresources com from www Manualslib com manuals search engine FORM Entries apply to the ADEMCO VISTA 15P VISTA 15PSIA and ADEMCO VISTA 20P VISTA 20PSIA controls except entries shown in dashed boxes which apply only to the VISTA 20P VISTA 20PSIA partition entries and are not applicable to the VISTA 15P VISTA 15PSIA In addition where noted certain fields have special settings when used with the VISTA 20PSIA VISTA 15PSIA indicated by V20PSIA V15PSIA with heavy borders and reverse type throughout for easy identification Entry of a number other than one specified will give unpredictable results Values shown in brackets are factory defaults SIA Guidelines Notes in certain fields give instructions for programming the VISTA 20P VISTA 15P for False Alarm Reduction Installer Code 4112 4 digits 0 Quick Arm Enable 0,0 0 no 1 yes Part 1 Part 2 RF Jam Option 0 0 no RF Jam detection 1 send RF Jam report UL must be 1 if wireless devices are used Quick Forced Bypass 0,0 0 no quick bypass UL must be Part 1 Part 2 1 allow quick bypass code 6 RF House ID Code 00,00,00 00 disable all wireless keypad usage Part 1 Part 2 Common 01 using 5827 5827BD or 5804BD keypad Chime By Zone 0 0 no 1 yes list chime zones on zone list 3 using 81 Menu mode Powerline Carrier Device X 0 House Code 0 A 1 B 2 C 3 D 4 E 5 F 6 G 7 H 8 I 9 J 10 K 11 L 12 M 13 N 14 O 15 P UL not for fire or UL installations Access Code For Phone Module 00 00 disable Partition 1 only 1st digit enter 1 2nd digit enter 11 for or 12 for UL must be for UL Commercial Burg installations Long Range Radio Output 0 0 disable 1 enable Single Alarm Sounding Per Zone 0 0 unlimited sounding 1 one alarm sounding per zone V20PSIA V15PSIA If selected sounding per zone will be the same as the of reports in armed period set in field 93 1 if one report 2 if 2 reports unlimited for zones in zone list 7 Fire Alarm Sounder Timeout 0 0 sound stops at timeout 1 no timeout UL must be for fire install Alarm Sounder Bell Timeout 1 0 none 1 4 min 2 8 min 3 12 min 4 16 min UL For residential fire alarm installation must be set for a minimum of 4 min option 1 for UL Commercial Burglary installations must be minimum 16 min option 4 Exit Delay 60,60 00 96 0 96 secs 97 120 secs Part 1 Part 2 SIA Guidelines minimum exit delay is 45 seconds V20PSIA V15PSIA 45 96 45 96 secs 97 120 se