Kidde K85001-1018 -- Kidde Intelligent Optica Rotary Smoke and Heat Detector

File Preview
File Preview
Click below to download for free

Text Preview

Intelligent Smoke Heat Detector Kidde Intelligent Optica Series KIR OSHD smoke detector advanced optical photoelectric sensing technology to a design that increases efficiency saves installation time costs and extends life safety and property protection Continuous self diagnostics ensure reliability the long haul while environmental compensation helps maintenance costs KIR OSHD provides an optical smoke sensor and a heat sensor with a fixed temperature setting these sensors efficiently detect smoldering fires well as fast flaming fires all Kidde Intelligent Optica Series detectors the KIR OSHD is intelligent device that gathers analog information from multiple sensors converting this data into digital signals Utilizing optical wavelengths combined with multiple detection angles KIR OSHD differentiates particles that are not representative actual smoke Particle data is input into digital filters which a series of ratios removing signal patterns that are typical of sources thus reducing unwanted alarms To make an decision the detector on board microprocessor measures analyzes all optical sensor readings and compares this to preprogrammed settings Reduce Cooking Alarms 268 7th Ed Features Multi criteria optical smoke sensing technology Integrates optical smoke with rate of rise heat sensing Wide 0.5 to 4.36 ft 1.6 to 13.6 m smoke obscuration Integrated nuisance rejection reducing unwanted alarms from cooking particulates Uses existing wiring Listed to UL 268 7th edition Sensor Markings Provide Easy Testing Identification Up To 250 detector and module Addresses Per Loop Two levels of environmental compensation Two levels of dirty detector warning Twenty pre alarm settings Five sensitivity settings Non volatile memory Rotary addressing 1 125 Automatic day night sensitivity adjustment Bicolor green red status LED Standard relay fault isolator and audible mounting bases Some features described here may not be supported by control systems Check your control panel Installation and Guide for details D A T A S H E E T K85001 1018 to be used for installation purposes Issue 1 1 of 4 Catalog u Intelligent Initiating DevicesTechnology that saves livesROTARY ADDRESSINGfirealarmresources com detection KIR OSHD detects particles from a wide range of combustion and will trigger an alarm when smoke density in the reaches preprogrammed level Thanks to its high reflective response technology the smoke sensor quickly and reliably to a wide range of fire types both fast and slow burning fires fueled by combustibles found in modern multi use buildings detection on board rate of rise heat sensor provides a 15 9 per minute function for the detection of fast developing while also providing a 135 57.2 fixed detection The heat sensors monitor the temperature of the and determines whether an alarm should be initiated KIR OSHD detector is compatible only with control panels a Kidde Intelligent Loop controller Criteria Detection Each detector houses an advanced chamber providing optical recognition of particles the onboard microprocessor to distinguish between particles and nuisance sources like cooking and steam Stable Communication On board intelligence means less needs to be sent between the detector and the loop Other than regular supervisory polling response the only needs to communicate with the loop controller when has something new to report Mounting Bases have wiring terminals that are from the after mounting the base to the box The bases mount to North American 1 gang boxes to 3 inch or 4 inch octagon boxes 1 inches 38 mm They also mount to European BESA and 1 gang boxes with mm fixing centers The KI SB4 KI RB4 and KI IB4 mount to American 4 inch sq electrical boxes in addition to the above They include the KI TS4 Trim Skirt which is used to cover ears on the base Sounder bases mount to a 4 square boxes only Intelligent Series detector mount to North American boxes 3 1 2 inch or 4 octagon boxes and to 4 square electrical boxes 1 1 2 38 mm deep They mount European BESA and 1 gang with 60.3 mm fixing See mounting base and wiring for information tab Indicator Maintenance maintenance regular or selected for proper operation should be planned to meet the requirements the Authority Having Jurisdiction AHJ Refer to current 72 NFPA 720 and ULC CAN ULC 536 standards Sensor Sensitivity KIR OSHD determines when its optical sensor is dirty or and can transmit sensitivity data to the loop controller sensitivity report can also be printed to satisfy NFPA sensitivity which must be conducted at the end of the first and every two years thereafter The availability of maintenance depends on the fire alarm system used and reporting technology microprocessor in each detector provides additional Self diagnostics and History Log Multi criteria detection Fast Stable Communication and History Log Each Kidde Intelligent detector constantly runs self checks to provide important information The results of the self check are updated and permanently stored in the detector memory Base Base LED LED GSA LED The remote LED connects to the KI SB KI SB4 Standard Base only It features a North American size plastic faceplate with a white finish and red alarm LED Base Base Skirt Supplied with 4 inch bases it can also be ordered to use with the other bases to help hide surface not covered by the smaller bases Bases Kidde Intelligent Series sounder bases designed for use where localized or group alarm signaling required KI ABST bases provide sounder capability to Kidde Intelligent smoke and heat detectors They are not for use with that include a CO sensor KI ABDT bases provide sounder capability to Kidde Series smoke and heat detectors as well as Kidde detectors that include a CO Sensor when used with FX T3T4 Temporal Pattern Generator to separate CO TC4 Fire TC3 tone patterns KI ABLT bases provide 520 Hz low frequency sounder to Kidde Intelligent Series smoke and heat as well as Kidde Intelligent detectors that include CO Sensor when used with a FX T3T4 Temporal Pattern to separate CO TC4 and Fire TC3 tone patterns KI ABLT is suitable for applications requiring low audible tones 2 of 4 D A T A S H E E T K85001 1018 to be used for installation purposes Issue 1 Detector Base KI RB KI RB4 base includes a relay Open or Normally operation is selected installation The dry is rated for 1 amp duty 30 Vdc The position is supervised avoid accidentally jarring it of position The KI RB be operated as a control if programmed to do so the control panel The relay does not support the Remote LED Kidde Controller Previous Device CONTACT RATING Amp 30 VDC Duty Term Description 1 Normally Open 2 DATA IN OUT 3 Common 4 DATA IN 5 Not Used 6 Normally Closed 7 DATA OUT Sounder Bases Fire Mode KI ABDT and KI ABLT sounder bases KI ABLT Setting High for dB cuts SIG OUT DATA DATA Mode Fire jumper Fire plus CO Setting Temporal jumper Steady Addressing is made easy through the rotary dials located on the of the detector head Use a screwdriver to adjust the TENS switch 0 through 12 to set the 10s digit and the ONES switch to set the digit 0 through 9 The control panel will any duplicate addresses 5 9 s

Related Files