Kidde K85001-1019 -- Kidde Intelligent Optica Rotary Smoke and CO Detector
File Preview
Click below to download for free
Click below to download for free
File Data
Name | kidde-k85001-1019-kidde-intelligent-optica-rotary-smoke-and-co-detector-5024183796.pdf |
---|---|
Type | |
Size | 1015.90 KB |
Downloads |
Text Preview
Intelligent Smoke CO Detector Kidde Intelligent Optica Series KIR OSCD smoke detector advanced optical photoelectric sensing technology to a design that increases efficiency saves installation time costs and extends life safety and property protection Continuous self diagnostics ensure reliability the long haul while environmental compensation helps maintenance costs KIR OSCD provides a combination of optical detection for early detection of smoke with the added element of carbon sensing The result is a detector that pulls double duty monitoring the environment for signs of fire as well as invisible yet deadly companion carbon monoxide all Kidde Intelligent Optica Series detectors the KIR OSCD is intelligent device that gathers analog information from multiple sensors converting this data into digital signals Utilizing optical wavelengths combined with multiple detection angles KIR OSCD differentiates particles that are not representative actual smoke Particle data is input into digital filters which a series of ratios removing signal patterns that are typical nuisance sources thus reducing unwanted alarms To make alarm decision the detector on board microprocessor and analyzes all optical sensor readings and compares information to preprogrammed settings The detector also the smoke sensor independently from the CO sensor to whether to initiate a fire alarm a life safety CO alarm both Reduce Cooking Alarms 268 7th Ed Features Multi criteria optical smoke sensing technology Integrates advanced optical smoke with life safety carbon detection Wide 0.5 to 4.36 ft 1.6 to 13.6 m smoke obscuration Integrated nuisance rejection reducing unwanted alarms from cooking particulates Sensor Markings Provide Easy Testing Identification Listed to UL 268 7th edition Uses existing wiring Ground fault detection by module Up To 250 detector and module Addresses Per Loop Two levels of environmental compensation Two levels of dirty detector warning Twenty pre alarm settings Five sensitivity settings Non volatile memory Rotary addressing 1 125 Automatic day night sensitivity adjustment Bicolor green red status LED Standard relay fault isolator and audible mounting bases Some features described here may not be supported all control systems Check your control panel Installation Operation Guide for details D A T A S H E E T K85001 1019 to be used for installation purposes Issue 1 1 of 4 Catalog u Intelligent Initiating DevicesTechnology that saves livesROTARY ADDRESSINGfirealarmresources com detection KIR OSCD detects particles from a wide range of combustion and will trigger an alarm when smoke in the chamber reaches a preprogrammed level Thanks its high performance reflective response technology the smoke responds quickly and reliably to a wide range of fire types both fast and slow burning fires fueled by combustibles found in modern multi use buildings Detection CO detection such as that provided by the KIR OSCD becoming mandated with increasing frequency in all types of applications but particularly in occupancies such as rooming houses dormitories day care facilities schools assisted living facilities and nursing homes Known as the Killer CO is odorless tasteless and colorless It claims nearly lives and results in more than 15,000 hospital visits annually KIR OSCD detector is compatible only with control panels a Kidde Intelligent Loop controller Intelligent Series detector mount to North American boxes 3 1 2 inch or 4 octagon boxes and to 4 square electrical boxes 1 1 2 38 mm deep They mount European BESA and 1 gang with 60.3 mm fixing centers mounting base installation and for more information tab Indicator and reporting technology microprocessor in each detector provides additional Self diagnostics and History Log multi criteria and Fast Stable Communication and History Log Each Kidde Intelligent detector constantly runs self checks to provide important information The results of the self check are updated and permanently stored in the detector memory Criteria Detection Each detector houses an advanced chamber providing optical recognition of particles the onboard microprocessor to distinguish between smoke and nuisance sources like cooking and steam Stable Communication On board intelligence means information needs to be sent between the detector and the controller Other than regular supervisory polling response detector only needs to communicate with the loop controller it has something new to report mounting bases have wiring terminals that are from the after mounting the base to the box The bases mount to North American 1 gang boxes to 3 inch or 4 inch octagon boxes 1 inches 38 mm They also mount to European BESA and 1 gang boxes with mm fixing centers The KI SB4 KI RB4 and KI IB4 mount to American 4 inch sq electrical boxes in addition to the above They include the KI TS4 Trim Skirt which is used to cover ears on the base Sounder bases mount to a 4 square boxes only LED GSA LED The remote LED connects to the KI SB KI SB4 Standard Base only It features a North American size Maintenance maintenance regular or selected for proper detector should be planned to meet the requirements of the Having Jurisdiction AHJ Refer to current NFPA 72 720 and ULC CAN ULC 536 standards Sensor Sensitivity KIR OSCD determines when its optical sensor is dirty or and can transmit sensitivity data to the loop controller sensitivity report can also be printed to satisfy NFPA sensitivity which must be conducted at the end of the year and every two years thereafter The availability of features depends on the fire alarm system used Sensor Life CO sensor has a 10 year life from the date of manufacture or the control panel indicates a sensor end of life condition comes first When the sensor reaches its end of life the signals a TRBL ACT condition on the control Pressing the Details button on the control panel displays OF LIFE ACT providing verification that it is an end of life of the CO sensor This trouble remains active until the is replaced even if the panel is reset Base Base Base Base LED plastic faceplate with a white finish and alarm LED Skirt Supplied with 4 inch bases it can also be ordered to use with the other bases to help hide surface not covered by the smaller bases Bases Kidde Intelligent Series sounder bases are for use where localized or group alarm signaling is KI ABDT bases provide sounder capability to the KIR OSCD used with a FX T3T4 Temporal Pattern Generator to CO TC4 and Fire TC3 tone patterns KI ABLT bases provide 520 Hz low frequency sounder to the KIR OSCD when used with a FX T3T4 Pattern Generator to separate CO TC4 and Fire tone patterns The KI ABLT is suitable for applications low frequency audible tones 2 of 4 D A T A S H E E T K85001 1019 to be used for installation purposes Issue 1 Detector Base KI RB KI RB4 base includes a relay Open or Normally operation is selected installation The dry is rated for 1 amp duty 30 Vdc The position is supervised avoid accidentally jarring it of position The KI RB be operated as a control if programmed to do so the control panel The relay does not support the Remote LED Sounder Fire Mode ABDT and sounder bases Kidde Controller Previous Device CONTACT RATING Amp 30 VDC Duty Term Description 1 Normally Open 2 DATA IN OUT 3 Common 4 DATA IN 5 Not Used 6 Normally Closed 7 DATA OUT ABST ABLT Setting High for dB