Mircom B300-6 and B300-6-IV Installation Manual
File Preview
Click below to download for free
Click below to download for free
File Data
Name | mircom-b300-6-and-b300-6-iv-installation-manual-8502639417.pdf |
---|---|
Type | |
Size | 1.19 MB |
Downloads |
Text Preview
I 3825 Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 inches 155 mm inches 19 mm to applicable sensor Operating Temperature Range using the Base Sensor Cross Reference Chart at systemsensor com 2 MOUNTING DETECTOR TO BOX AND MAINTENANCE INSTRUCTIONS and B300 6 IV Plug in Detector Bases Diameter Height Temperature Ratings Voltage Current UL268 to 32 VDC INSTALLING read the System Smoke Detectors Application Guide which provides information on detector spacing placement zoning wiring and spe applications Copies of this application guide are available from System NFPA 72 guidelines should be observed This manual should be left with the owner user of this equipment The detector used with this base must be tested and maintained following NFPA 72 requirements The detector should be cleaned at once a year DESCRIPTION B300 6 and B300 6 IV are plug in detector bases intended for use in an system with screw terminals provided for power and and annunciator connections Communication takes place over the power and TERMINALS FUNCTION 1 TERMINAL LAYOUT Remote Annunciator Annunciator 2 3 1 detector base mounts directly to 4 inch square with and without plaster 4 inch octagon 31 2 inch octagon and single gang junction boxes To remove the decorative ring by turning it in either direction to unhook snaps then separate the ring from the base Install the base on the box the screws supplied with the junction box and the appropriate mounting in the base C0127 07 the decorative trim ring on the base and rotate it in either direction until snaps into place See Figure 2 ON SUPPLIED SUPPLIED C2036 01 AND WIRING GUIDELINES SEE FIGURE 3 wiring must be installed in compliance with all applicable local codes any special requirements of the authority having jurisdiction Proper wire should be used The conductors used to connect smoke detectors to panels and accessory devices should be color coded to reduce the like of wiring errors Improper connections can prevent a system from re properly in the event of a fire signal wiring the wiring between interconnected detectors it is recom that the wire be no smaller than 18 AWG 0.823 mm Wire sizes up 12 AWG 3.31 mm may be used with the base electrical connections by stripping about 3 8 inch 10 mm of insulation the end of the wire use strip gauge molded in base Then slide the wire the clamping plate and tighten the clamping plate screw Do not loop wire under the clamping plate See Figure 4 the zone wiring of all bases in the system before installing the detec This includes checking the wiring for continuity correct polarity ground testing and performing a dielectric test base includes an area for recording the zone address and type of detec being installed This information is useful for setting the detector head and for verification of the detector type required for that location all detector bases have been wired and mounted and the loop wiring been checked the detector heads may be installed in the bases FEATURE Do not use the tamper resist feature if a removal tool will be used 5A ACTIVATE TAMPER RESIST FEATURE LEVER detector base includes a tamper resist feature that prevents removal of the without using a small screwdriver or similar tool activate this feature use needle nose pliers to break the tab on the detector as shown in Figure 5A Then install the detector remove the detector from the base once the tamper resist feature has been remove the decorative ring by rotating it in either direction and it away from the base Then insert a small screwdriver into the notch indicated in Figure 5B and press the plastic lever toward the mounting before rotating the detector counterclockwise for removal LEVER tamper resist feature can be defeated by breaking and removing the plas lever from the base However this prevents the feature from being used ANNUNCIATOR RA100Z the remote annunciator between terminals 1 and 3 using the spade terminal included The spade lug terminal is connected to the base termi as shown in Figure 6 TAB AT DOTTED LINE BY TOWARD CENTER OF BASE is not acceptable to have three stripped wires under the same wiring ter unless they are separated by a washer or equivalent means The spade supplied with the model RA100Z is considered an equivalent means See 3 for proper installation 3 TYPICAL WIRING DIAGRAM FOR 2 WIRE LOOP DO NOT LOOP WIRE TERMINAL 1 OR 2 WIRE RUN TO PROVIDE OF CONNECTIONS A OPTIONAL WIRING 4 TERMINAL WIRE INSTALLATION TAB AT DOTTED LINE BY TOWARD CENTER OF BASE 5B DETECTOR REMOVAL SMALL BLADED SCREWDRIVER TO PUSH LEVER IN DIRECTION OF ARROW 6 CONNECTION TO REMOTE ANNUNCIATOR TERMINAL WIRE WITH SPADE LUG refer to insert for the Limitations of Fire Alarm Systems LIMITED WARRANTY Sensor warrants its enclosed smoke detector base to be free from defects in ma and workmanship under normal use and service for a period of three years from of manufacture System Sensor makes no other express warranty for this smoke base No agent representative dealer or employee of the Company has the au to increase or alter the obligations or limitations of this Warranty The Company of this Warranty shall be limited to the repair or replacement of any part of smoke detector base which is found to be defective in materials or workmanship normal use and service during the three year period commencing with the date of After phoning System Sensor toll free number 800 SENSOR2 736 7672 a Return Authorization number send defective units postage prepaid to Honeywell Rojas Drive Suite 700 El Paso TX 79936 USA Please include a note describing the and suspected cause of failure The Company shall not be obligated to repair replace units which are found to be defective because of damage unreasonable use or alterations occurring after the date of manufacture In no case shall the be liable for any consequential or incidental damages for breach of this or any Warranty expressed or implied whatsoever even if the loss or damage is caused by Company negligence or fault Some states do not allow the exclusion or limitation of or consequential damages so the above limitation or exclusion may not apply you This Warranty gives you specific legal rights and you may also have other rights vary from state to state Sensor is a registered trademark of Honeywell International Inc System Sensor 11 17 2017