Mircom B300A-6 and B300A-6-IV Installation Manual
File Preview
Click below to download for free
Click below to download for free
File Data
Name | mircom-b300a-6-and-b300a-6-iv-installation-manual-7542103689.pdf |
---|---|
Type | |
Size | 1.22 MB |
Downloads |
Text Preview
I Kitimat Road Unit 6 Mississauga Ontario L5N 3T5 FAX 905 812 0771 inches 155 mm inches 19 mm to applicable sensor Operating Temperature Range using the Base Sensor Cross Reference Chart at systemsensor com 2 MOUNTING DETECTOR TO BOX AND MAINTENANCE INSTRUCTIONS and B300A 6 IV Plug in Detector Bases Diameter Height Temperature Ratings Voltage Current ULC S529 to 32 VDC INSTALLING read the System Smoke Detectors Application Guide which provides information on detector spacing placement zoning wiring and spe applications Copies of this application guide are available from System CAN ULC S524 guidelines should be observed This manual should be left with the owner user of this equipment The detector used with this base must be tested and main regularly following CAN ULC S536 requirements The detector should cleaned at least once a year DESCRIPTION B300A 6 and B300A 6 IV are plug in detector bases intended for use in an system with screw terminals provided for power and and annunciator connections Communication takes place over the power and TERMINALS FUNCTION 1 TERMINAL LAYOUT Remote Annunciator Annunciator 2 3 1 detector base mounts directly to 4 inch square with and without plaster 4 inch octagon 31 2 inch octagon and single gang junction boxes To remove the decorative ring by turning it in either direction to unhook snaps then separate the ring from the base Install the base on the box the screws supplied with the junction box and the appropriate mounting in the base C0127 07 the decorative trim ring on the base and rotate it in either direction until snaps into place See Figure 2 ON SUPPLIED SUPPLIED AND WIRING GUIDELINES SEE FIGURE 3 wiring must be installed in compliance with all applicable local codes any special requirements of the authority having jurisdiction Proper wire should be used The conductors used to connect smoke detectors to panels and accessory devices should be color coded to reduce the like of wiring errors Improper connections can prevent a system from re properly in the event of a fire C2036 01 signal wiring the wiring between interconnected detectors it is recom that the wire be no smaller than 18 AWG 0.823 mm Wire sizes up 12 AWG 3.31 mm may be used with the base electrical connections by stripping about 3 8 inch 10 mm of insulation the end of the wire use strip gauge molded in base Then slide the wire the clamping plate and tighten the clamping plate screw Do not loop wire under the clamping plate See Figure 4 the zone wiring of all bases in the system before installing the detec This includes checking the wiring for continuity correct polarity ground testing and performing a dielectric test base includes an area for recording the zone address and type of detec being installed This information is useful for setting the detector head and for verification of the detector type required for that location all detector bases have been wired and mounted and the loop wiring been checked the detector heads may be installed in the bases 5A ACTIVATE TAMPER RESIST FEATURE LEVER TAB AT DOTTED LINE BY TOWARD CENTER OF BASE 5B DETECTOR REMOVAL SMALL BLADED SCREWDRIVER TO PUSH LEVER IN DIRECTION OF ARROW 6 CONNECTION TO REMOTE ANNUNCIATOR TERMINAL WIRE WITH SPADE LUG FEATURE Do not use the tamper resist feature if the removal tool will be used detector base includes a tamper resist feature that prevents removal of the without using a small screwdriver or similar tool activate this feature use needle nose pliers to break the tab on the detector as shown in Figure 5A Then install the detector remove the detector from the base once the tamper resist feature has been remove the decorative ring by rotating it in either direction and it away from the base Then insert a small screwdriver into the notch indicated in Figure 5B and press the plastic lever toward the mounting before rotating the detector counterclockwise for removal LEVER tamper resist feature can be defeated by breaking and removing the plas lever from the base However this prevents the feature from being used ANNUNCIATOR RA100ZA the remote annunciator between terminals 1 and 3 using the spade terminal included The spade lug terminal is connected to the base termi as shown in Figure 6 TAB AT DOTTED LINE BY TOWARD CENTER OF BASE is not acceptable to have three stripped wires under the same wiring ter unless they are separated by a washer or equivalent means The spade supplied with the model RA100ZA is considered an equivalent means See 3 for proper installation 3 TYPICAL WIRING DIAGRAM FOR 2 WIRE LOOP DO NOT LOOP WIRE TERMINAL 1 OR 2 WIRE RUN TO PROVIDE OF CONNECTIONS A OPTIONAL WIRING 4 TERMINAL WIRE INSTALLATION refer to insert for the Limitations of Fire Alarm Systems LIMITED WARRANTY Sensor warrants its enclosed smoke detector base to be free from defects in ma and workmanship under normal use and service for a period of three years from of manufacture System Sensor makes no other express warranty for this smoke base No agent representative dealer or employee of the Company has the au to increase or alter the obligations or limitations of this Warranty The Company of this Warranty shall be limited to the repair or replacement of any part of the detector base which is found to be defective in materials or workmanship under use and service during the three year period commencing with the date of manu After phoning System Sensor toll free number 800 SENSOR2 736 7672 for a Authorization number send defective units postage prepaid to System Sensor Department RA 6581 Kitimat Road Unit 6 Mississauga Ontario Please include a note describing the malfunction and suspected cause of fail The Company shall not be obligated to repair or replace units which are found to be because of damage unreasonable use modifications or alterations occurring the date of manufacture In no case shall the Company be liable for any consequen or incidental damages for breach of this or any other Warranty expressed or implied even if the loss or damage is caused by the Company negligence or fault states do not allow the exclusion or limitation of incidental or consequential dam so the above limitation or exclusion may not apply to you This Warranty gives you legal rights and you may also have other rights which vary from state to state Sensor is a registered trademark of Honeywell International Inc System Sensor 11 17 2017