Mircom CAT-5005 FA-106 Six Zone Fire Alarm Unit (English)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | mircom-cat-5005-fa-106-six-zone-fire-alarm-unit-english-0957168243.pdf |
---|---|
Type | |
Size | 995.20 KB |
Downloads |
Text Preview
SIX ZONE FIRE ALARM UNIT Six Class Input circuits Two Class Output circuit 2.0Amps Meets latest ULC S 527 2011 Standard Signal Silence Audible tones are DIP Switch selectable for Steady Temporal Code Powerful 3 mA capacity per zone for 2 wire smoke Common alarm Relay contact Form C 28 VDC 3 AMP Resistive Common trouble Relay contact Form C 28 VDC 3 Amp Resistive A C ON LED Green Zone Alarm LED Amber Signal Trouble LED Amber Ground Fault LED Amber Battery Fault LED Amber Alarm Silenced LED Amber Common Trouble LED Silence button Remote Trouble Indicator output Selectable 1 minute Signal silence inhibit Extensive Transient Protection on all circuits White or Red exterior colours All circuits are power limited Fully regulated 24 VDC Auxiliary Power 250mA All configurations performed by DIP switch FA 106 has selectable audible tones which can configured via DIP for Steady and Temporal Code panel also includes a common alarm relay which is via DIP switch to follow the signal circuit lock on until the Alarm has been reset cabinet is available in white or red colour and Fire Retardant Lexan Window in the hinged door for viewing of the status LEDs It comes with a CAT 30 lock and key Space is provided for 5 7.0 AH batteries Mircom FA 106 panel is designed for fire alarm in small commercial institutional and industrial A slim line design and a white exterior offer unobtrusive appearance to compliment exterior FA 106 includes one circuit board providing all the for a complete fire alarm system Six Class Input circuits and two Class Output circuits 2.0 1.25 maximum per circuit are provided by the The Output circuits are protected from shorts self restoring circuitry FA 106 is equipped with supervision for ground detection battery low level or open wire fault and Output circuit wiring faults and loss of A C The initiating circuits are supervised for opens ground faults The FA 106 has LED indicators Zone Alarm Zone Trouble A C On Battery Fault Fault Common Trouble Signal Trouble and Silences and buttons for Zone Disconnect Buzzer Silence and Reset reserves the right to make changes at any time without notice in prices colours materials components equipment specifications and models and also to discontinue models TO BE USED FOR INSTALLATION PURPOSES NUMBER and Output Circuits Wiring Diagram and trouble relay contacts Diagram Diagrams Station threshold current is 15.5 mA loop resistance is 100 ohms shorts on Input and Output circuits will cause a trouble of greater than 1M Ohm on Input and Output will cause a trouble zone 1 Regulated max alarm Regulated max alarm Regulated max alarm Regulated max alarm Regulated max alarm Regulated max alarm zone 2 zone 3 zone 4 zone 5 zone 6 RMS FWR max RMS FWR max NAC zone 1 NAC zone 2 Specifications Circuits Voltage VDC fully regulated Limited mA Current mA up to 30 2 wire smoke detectors 100 uA each ohms max 5 1 2W Resistance of Line Resistor CONNECTION 24VDC 250mA max Resettable or Always ON 24V DC Not used 16.5 mA max trouble buzzer 16.5 mA max trouble amber Alarm contacts 3A resistive trouble relay contacts 3A C O C O power OF LINE RELAY S3705 ELOR 1A BY SENSOR W 4 WIRE DETECTOR WIRING DETECTOR APPLICATION Aux 24V DC either to a RTI 1 OR to detection device Cannot be both ULC Listed 4 wire smoke detectors rated 24V 24V DC 24VDC 250mA max Circuits Voltage Current of Line Resistor Contacts Power VDC FWR 1.25A max per circuit 1 2W VDC 3A Resistive 347mm W x 12.7 322mm H x 71mm D Information Zone Fire Alarm Unit White Door Zone Fire Alarm Red Door Trouble indicator mounts onto a single gang electrical box Trim Ring Battery Battery TO BE USED FOR INSTALLATION PURPOSES by Interchange Way Ontario L4K 5W3 905 660 4655 905 660 4113 Witmer Industrial Estates Falls NY 14305 Free 888 660 4655 Toll Free 888 660 4113 page http www mircom com Email mail mircom com 5005