Honeywell Fire Sentry SS2 Series Flame Detector

File Preview
File Preview
Click below to download for free

File Data

Name honeywell-fire-sentry-ss2-series-flame-detector-2605819437.pdf
Type PDF
Size 1020.27 KB
Downloads

Text Preview

Fire Sentry SS2 Fire and Flame Detectors UV IR Flame Detector and Flame Detector Sentry SS2 Multi Spectrum senses energy in the UV Vis WideBand IR False alarm immunity Detects hydrocarbon and non hydrocarbon Microprocessor based algorithms FirePic Tri Mode Plot Wide field of view and solar blind Wide temperature range of operation Explosion proof housing FS2000 System compatible or stand operation Compatible with approved fire alarm panels SS2 AN UV IR Fire and Flame Gas Petrochemical Facilities Turbines Stations Plants Hydrogen Gas Storage Hangers SS2 AML UV IR Speed Digital Fire Flame Detector production production of other explosive material Hydrogen gas storage SS2 AHD UV IR Speed Digital Fire Flame Detector Azide propellant manufacture Air Bag manufacture SS2 AN Multi Spectrum Electro Optical Fire Detector Sentry SS2 A and Fire Sentry SS2 AN Fire Sentry SS2 A latching Fire Alarm relay and Fire Sentry SS2 AN non Fire Alarm relay represent the world pre eminent UV IR technology Electro Optical fire and flame detectors with thousands successfully in a multitude of installations worldwide This detector senses radiant in the Ultraviolet UV Visible and Wide Band IR spectrum The radiant from all types of flaming fires will alert the detector to their presence field of view is the widest in the industry with a 120 cone of vision This each detector can cover more hazard area Greater sensitivity also the volume of coverage by the detector up to four times more than other detectors Sentry SS2 AM and Fire Sentry SS2 AML Fire Sentry SS2 AM latching Fire Alarm relay and Fire Sentry SS2 non latching Fire Alarm relay represent the world pre eminent Ultra Speed UV IR technology for Electro Optical fire and flame detectors operating in a multitude of installations worldwide This detector radiant energy in the Ultraviolet UV Visible and Wide Band IR The radiant energy from all types of flaming fires will alert the detector their presence field of view is the widest in the industry with a 120 cone of vision This each detector can cover more hazardous area Sentry Corporation Patents Sentry SS2 field of view for the Fire SS4 detectors is the in the industry with a 120 of vision This means more area can be covered by detector Greater sensitivity increases the volume by each detector up to times more than some other sophisticated signal processing false alarm rejection maximized with virtual to false alarms from arc corona discharge and common non fire sources SS2 operates from standard 24 Volt DC power and interfaces to approved alarm panels or standard PLC When power is applied an internal self is performed and the fault relay resets to show no faults The detector is in normal operation front LEDs flash every ten seconds to indicate power is on The spectral data stream of information from the sensor array is by the microprocessor On Alarm the detector activates the alarm and stores all of the pre fire spectral data from the sensor array in non memory for retrieval and evaluation This Fire Pic data can be used postulate the cause of the fire part of the FS2000 System the the lens and complete optical can be checked using COP i Test Sources in the system into the FS2000 System is by the four wire RS 485 Plot Shown on Computer Display 185 40 to 85 C 4 Range to 90 RH non condensing Sensitivity 15 Degrees of View Horizontal and Vertical to 1 sq ft Gasoline Pan Fire SS2 Side View SS2 Back View Time seconds to 1 sq ft of gasoline pan at 60 ft degrees cone of vision degrees from on axis Sensitivity 185 to 260 nanometers Power Outputs INFORMATION Band Infrared 0.7 to 3.5 micrometers 400 to 700 nanometers VDC nominal 20.4 to 34 VDC mA normal operation typical mA alarm condition typical Alarm Relay NO NC contacts Latching Non Latching factory set Normally de energized Relay NO NC contacts Normally energized Relay contact ratings 0.5 A at 120 VAC 1.0 A at 24 VDC pounds Aluminum pounds Stainless Steel aluminum less than 0.4 coated NEMA4 IP66 tamper resistant integral dual 3 4 NPT conduit openings steel housing available I Div 1 2 Groups B C D II Div 1 2 Groups E F G III bracket assembly years from factory shipping date warranty available Detector latching Detector non latching Steel Swivel Mount Test Lamp Controller business centre 82 2 69090300 65 65803776 61 3 94642770 886 3 5169284 86 21 28943293 Services ha ap service honeywell com ha emea service honeywell com ha us service honeywell com Note every effort has been made to ensure accuracy in this publication no can be accepted for errors or omissions Data may change as well legislation and you are strongly advised to obtain copies of the most recently regulations standards and guidelines This publication is not intended to the basis of a contract 06 12 2012 Honeywell Analytics

Related Files