Fire Sentry SS4 Fire and Flame Detectors and UV IR Electro Optical Fire and Flame Detectors Sentry SS4 Sentry SS4 A and Features Multi Spectrum senses ultraviolet and Wide Band Infrared Built in test for optical the testing False alarm immunity Detects hydrocarbon and non based fires Wide field of view and solar blind Adjustable detector sensitivity Microprocessor based algorithms Snapshot and Plot Wide temperature range of operation Compatible with standard approved fire panels Explosion proof housing Time programmable alarm verification Sentry SS4 AUV Senses testing based fires Wide Adjustable Wide panels Explosion proof Time include Petrochemical Facilities and Refineries Co Generation Plants Aircraft Hangars Silane and Hydrogen Gas Storage Gas Turbines Power Plants Gas Compressor Stations Warehouses Fire Sentry SS4 Electro Optical Digital and Flame Detectors represent edge UV and UV IR technology SS4 A Fire Sentry SS4 A represents the world pre eminent UV IR technology for Flame Detectors with tens of thousands successfully operating in multitude of installations worldwide This multi spectrum detector senses radiant in the ultraviolet UV visible and Wide Band Infrared IR spectrum The energy from all types of flaming fires will alert the detector to their presence eliminate common nuisance false alarms that occasionally occur with IR only Dual IR or Dual Mode UV IR detectors the Fire Sentry SS4 FireLogic signal processing requires that UV visible and Wide IR radiant energy all be evaluated before declaring a fire The smart utilizes real time signal processing algorithms that are optimized alarm on all types of fires while virtually eliminating the possibility of alarms Sentry SS4 AS Fire Sentry SS4 AS processes UV IR and Visible VIS spectral ranges from solar blind UV IR and VIS sensors correspondingly is optimized for detection of hydrogen ethanol methanol and methane natural fires and like the other detectors in its family it responds to Type A B and C fires Sentry SS4 AUV Fire Sentry SS4 AUV represents the leading edge technology UV optical detectors This flame detector senses radiant energy in the ultraviolet UV The radiant emissions of flaming fires will alert the detector to presence Sentry SS4 field of view for the Fire SS4 detectors is the in the industry with a 120 of vision This means more area can be covered by detector Greater sensitivity increases the volume by each detector up to times more than some other sophisticated signal processing false alarm rejection maximized with virtual to false alarms from arc corona discharge and common non fire sources Fire Sentry SS4 detectors operate from standard 24 Volt DC power and to approved fire alarm panels or standard PLC When power is a self test is performed and the fault relay resets to show no faults front LED lights flash every ten seconds to indicate power is on continuous spectral data stream of information from the sensor array is by the microprocessor Upon alarm the detector activates the relay and stores all the pre fire spectral data in non volatile memory for and evaluation This Fire Pic data can be used to postulate the of the fire part of the FS2000 System the SS4 family of detectors communicate CM1 A Controller via a four wire bi directional RS 485 FireBus Plot Shown on Computer Display Specifications Time Sensitivity Power Consumption between 60 ft 45 ft 30 ft and 15 ft to a 1 sq ft gasoline fire seconds to 1 sq ft of gasoline fire at 60 ft degrees cone of vision 60 degrees from on axis 185 to 260 nanometers Wide Band Infrared 0.7 to 3.5 micrometers SS4 A and SS4 AS only 400 to 700 nanometers SS4 A and SS4 AS only VDC nominal 20.5 to 34 VDC mA normal operation relay version mA alarm condition relay version 95 mA alarm condition analog version Relays Alarm Relay NO NC contacts Latching Non Latching switch selectable Verify Relay NO NC contacts Adjustable time from 0 to 30 seconds Relay NO NC contacts Relay contact ratings 0.5A at 120 VAC 1.0A at 24VDC Fault relay is energized during normal operation All other relays are de energized Temperature Range to 185 40 to 85 to 98 RH non condensing pounds Aluminum pounds Stainless Steel Classification steel housing available aluminum less than 0.4 powder coated NEMA4 IP66 tamper with integral dual NPT conduit openings or optional M25 I Div 1 2 Groups B C and D II Div 1 2 Groups E F and G III bracket assembly years from factory shipping date or exceeds MIL Spec 810 C Method 514.2 Curve AW Sensitivity Sensitivity of View Horizontal and Vertical of View Horizontal and Vertical to 1 sq ft Gasoline Pan Fire to 1 sq ft Gasoline Pan Fire Dimensions and Back Views Dimensions in Inches 15 4 business centre 82 2 69090300 65 65803776 61 3 94642770 886 3 5169284 86 21 28943293 Services ha ap service honeywell com ha emea service honeywell com ha us service honeywell com Note every effort has been made to ensure accuracy in this publication no can be accepted for errors or omissions Data may change as well legislation and you are strongly advised to obtain copies of the most recently regulations standards and guidelines This publication is not intended to the basis of a contract 09 12 2012 Honeywell Analytics